CFD-CD777SMK2
TUNER  SECTION
0 dB=1 
µ
V
[FM]
Setting:
FUNCTION switch : RADIO
BAND switch : FM
[MW]
Setting:
FUNCTION switch : RADIO
BAND switch : MW
[SW]
Setting:
FUNCTION switch : RADIO
BAND switch : SW1/SW2
FINE TUNING knob ...................................... Mechanical center
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
FM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter
L2
86.5 MHz
CT2
109.5 MHz
FM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
L1
86.5 MHz
CT1
109.5 MHz
AM  IF  ADJUSTMENT
Adjust for a maximum reading on level meter
T1
455 kHz
MW  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter
L4
520 kHz
CT4
1,680 kHz
MW  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
L3
620 kHz
CT3
1,400 kHz
SW1  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter
L6
2.2 MHz
CT6
7.3 MHz
SW1  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
L5
2.2 MHz
CT5
7.3 MHz
SW2  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter
L8
6.8 MHz
CT8
22.5 MHz
SW2  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter
L7
6.8 MHz
CT7
22.5 MHz
FM  VCO Adjustment
Setting:
Procedure:
1. Connect the frequency counter to pin 4 and 7 of IC1 as shown
the figure below.
2. Tune the set to 98 MHz.
3. Adjust RV2 for 76 kHz 
± 500 Hz reading on the frequency
counter.
Adjustment Location: MAIN board (See page 14)
Put the lead-wire
antenna close to 
the set.
AM RF SSG
30% amplitude modulation by
400 Hz signal
output level: as low as possible
FM RF SSG
0.01 
µ
F
FM/SW
telescopic
antenna
terminal
22.5 kHz frequency deviation
by 400 Hz signal.
output level: as low as possible
AM RF SSG
12 PF
FM/SW
telescopic
antenna
terminal
30% amplitude modulation by
400 Hz signal
output level: as low as possible
+
set
32 
PHONES jack (J301)
level meter
0.001 
µ
F
MAIN board
IC1 pin 
qk
set
FM RF SSG
Carrier frequency : 98 MHz
Modulation
: 400 Hz, 30% FM modultion
Output level
: 0.1 V (100 dB)
+
MAIN board
IC1 pin 
4
+
IC1 pin 
7
µ
F
33 k
 
frequency counter
14
CFD-CD777SMK2
Adjustment Location:
T1 AM IF Adjustment
RV2
FM VCO Adjustment
L3 CT3
FM Tracking
Adjustment
MW Tracking
Adjustment
CT2
L2
L5
CT5
L4
CT4
MW Frequency
Coverage 
Adjustment
SW1
Frequency
Coverage 
Adjustment
FM Frequency
Coverage 
Adjustment
SW1
Tracking
Adjustment
SW2
Tracking
Adjustment
CT1
L1
CT7
L7
L6 CT6
SW2
Frequency
Coverage 
Adjustment
L8 CT8
RV302
Tape Speed
Adjustment
FM/SW
Antenna
Terminal
IC1
JW27
– MAIN BOARD (Component Side) –
15
CFD-CD777SMK2
CD SECTION
Notes on Adjustment
1. Perform adjustment in test mode.
After adjustments, be sure to release test mode.
2. Perform adjustments in the order given.
3. Use the disc (YEDS-18. Part No. 3-702-101-01) only when so
indicated.
How to Put the Set into Test Mode
1. Short-circuit the JW811 and JW812 on the CONTROL board.
2. Turn on the power.
3. Open the short-circuit to release test mode.
– CONTROL BOARD (Component Side) –
+
MAIN board
Solder bridge (TRACKING)
TP (VC)
oscilloscope
(DC range)
A
B
A
B
A=B
0 V
0 V
C
A=B     C=180 mVp-p to 420 mVp-p
E-F Balance Adjustment
This adjustment is to be done when the optical pick-up is replaced.
Procedure:
1. Connect the oscilloscope to solder bridge (TRACKING) and
TP (VC) on the MAIN board.
2. Put the set into test mode.
3. Optical pick-up setting to the center by > or . button
pushing.
4. Put the disc (YEDS-18) and press NX button.
From focus searching, focus is turned ON while entering
CLV drawing-in mode. Tracking and sled are turned OFF.
5. Adjust RV703 so that the oscilloscope traverse waveform is
symmetrical, as shown in the figure below.
6. Release the test mode after adjustment is completed.
Note: Take long sweep time
for easy monitoring.
VOLT/DIV : 0.2 V (with the 10:1 probe in use.)
TIME/DIV : 5 ms
Adjustment Location: MAIN board (See page 18)
Before Begining Adjustment
Put the set into test mode and perform the following checks.
Repair if there are any problems.
• Sled Motor Check
Press the >, . buttons and confirm that the optical pick-up
moves smoothly from the innermost to outermost circumference
and back smoothly and with no catching or abnormal noises.
> : Optical pick-up moves to the outer circumference
. : Optical pick-up moves to the inner circumference
• Focus Search Check
1. Press the NX button. (Focus search operation is performed
continuously.)
2. Look at the optical pick-up objective lens and confirm that it
moves up and down smoothly, when no catching or abnormal
noises.
3. Press the x button.
Confirm that focus search operation stops. If it does not , press
the x button again longer.
LCD801
IC801
JW811
JW812
16
CFD-CD777SMK2
Focus Tracking/Gain  Adjustment
A frequency response analyzer is necessary in order to perform
this adjustment exactly.
However, this gain has a margin, so even if it is slightly off, there
is no problem. Therefore, do not perform this adjustment.
Focus Tracking/gain determines the pick-up follow-up (vertical
and horizontal) relative to mechanical noise and mechanical shock
when the 2-axis device operate.
However, as these reciprocate, the adjustment is at the point where
both are satisfied.
• When gain is raised, the noise when the 2-axis device operates
increases.
• When gain is lowered, mechanical shock and skipping occurs
more easily.
• When gain adjustment is off, the symptoms below appear.
The following is a simple adjustment method.
– Primary Adjustment –
Note:
Since exact adjustment cannot be performed, remember the posi-
tions of the controls before performing the adjustment. If the posi-
tions after the primary adjustment are only a little different, return
the controls to the original position.
Connection:
• The time until music starts becomes longer for
STOP 
→ NX button or automatic selection.
(., > buttons pressed.)
(Normally takes about 2 seconds.)
• Music does not start and disc continues to
rotate for STOP 
→ NX button or automatic
selection.
(., > buttons pressed.)
• Sound is interrupted during PLAY.
Or time counter display stops progressing.
• More noise during 2-axis device operation
Gain
Focus
Tracking
Symptoms
low
low
or
high
low
low
high
high
+
Solder bridge (TRACKING)
Solder bridge (FOCUS)
TP (VC)
oscilloscope
(DC range)
Focus Bias Adjustment
This adjustment is to be done when the optical pick-up is replaced.
Procedure:
1. Connect the oscilloscope to solder bridge (FOCUS) and TP
(VC) on  the MAIN board.
2. Put the set into test mode. (See page 24.)
3. Optical pick-up setting to the center by > or . button
pushing. (Move the optical pick-up to the music area on the
disc to enable easy visibility of the eye pattern.)
4. Put the disc (YEDS-18) and press NX button.
From focus searching, focus is turned ON while entering
CLV drawing-in mode. Tracking and sled are turned OFF.
5. Press the NX button.
[Both tracking and sled are turned ON.]
6. Adjust RV701 so that the oscilloscope waveform is as shown
in the figure below (eye pattern).
A good eye pattern means that the diamond shape (
≈ ) in the
center of the waveform can be clearly distinguished.
7. Release the test mode after adjustment is completed.
• RF signal reference waveform (eye pattern)
Adjustment Location: MAIN board (See page 18)
+
MAIN board
Solder bridge (FOCUS)
TP (VC)
oscilloscope
(AC range)
VOLT/DIV: 0.2 V (with the 10: 1 probe in use)
TIME/DIV: 500 ns
1.2 
±
 0.2 Vp-p
When observing the eye pattern, set the oscilloscope 
for AC range and raise vertical sensitivity.