– 9 –
Record/Playback Head Azimuth Adjustment
Procedure :
1. Mode : playback
test tape
P-4-A063
(6.3kHz, –10dB)
set
33
J302 (phones)
level meter
+
L-CH
peak
R-CH
peak
L-CH
peak
R-CH
peak
Screw
position
output
level
within
2dB
within
2 dB
screw position
2. Turn the adjustment screw for the maximum output levels. If
   these levels do not match, turn the adjustment screw until both
   of output levels match together within 2dB. 
3. Phase Check
Mode : playback
L-CH
H
V
L-CH
set
33
R-CH
R-CH
33
in phase     45
°
        90
°
       135
°
      180
°
good
wrong
screen pattern
test tape
P-4-A063
(6.3kHz, –10dB)
J302 (phones)
oscilloscope
+
+
Adjustment Location : – record / playback head –
adjustment screw
REC/PB head
 TUNER SECTION
 AM Section
Function switch
: AM
Volume
: MAX
AM RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
 FM Section
Function switch
: FM
Volume
: MAX
FM RF signal
generator
22.5kHz frequency deviation by 
400Hz signal.
Output level : as low as possible
telescopic
antenna
terminal
0.01  F
µ
set
33
+
J302 (phones)
level meter
r
Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally done
by the trimmer capacitors.
no mark
: E, Central & South America model
 [        ]
: AEP, UK model
((       ))
: Italian model
 <       >
: East European model
                         AM IF ALIGNMENT
           Adjust for a maximum reading on level meter.
CFT1
455kHz
[ 455kHz]
(( 455kHz))
< 455kHz>
    AM FREQUENCY COVERAGE ADJUSTMENT
           Adjust for a maximum reading on level meter.
L4
520kHz
[520kHz]
((516kHz))
<520kHz>
CT4
1,680kHz
[1,680kHz]
((1,630kHz)) <1,680kHz>
                AM TRACKING ADJUSTMENT
          Adjust for a maximum reading on level meter.
L3
620kHz
[620kHz]
((620kHz))
<620kHz>
CT3
1,400kHz
[1,400kHz]
– 10 –
    FM FREQUENCY COVERAGE ADJUSTMENT
               Adjust for a maximum reading on level meter.
L2
86.5MHz
[87.0MHz] ((87.35MHz )) <64.0MHz>
CT2
109.5MHz
[108.3MHz] ((108.25MHz)) <109.5MHz>
                  FM TRACKING ADJUSTMENT
            Adjust for a maximum reading on level meter.
L1
86.5MHz
[87.0MHz] ((87.35MHz )) <64.0MHz>
CT1
109.5MHz
[108.3MHz] ((108.25MHz)) <109.5MHz>
Adjustment Location : Tuner board (page 13)
VCO Adjustment
Procedure :
FM RF signal
generator
set
0.01  F
Carrier frequency : 98MHz
Modulation : no modulation
Output level : 1.38mV (–55dB)
µ
telescopic
antenna
terminal
1. Connect the frequency counter to 4 and 7 pins of IC1 as shown
the figure below.
2. Turn the set to 98MHz.
3. Adjust RV1 for 76 kHz 
±
 500 Hz reading on frequency counter.
frequency counter
 
F
33k
µ
[ TUNER BOARD ]
+
Adjustment Location : Tuner board (page 13)
 CD SECTION
Note on Adjustment
1. Perform adjustment in test mode.
After adjustment, be sure to release test mode.
2. Perform adjustments in the order given.
3. Use the disc (YEDS-18. Part No. 3-702-101-01) only when  so
indicated.
Before adjustment
Put the set into test mode and perform the following checks.
Repair if there are any problems.
r
 Sled Motor Check
1. Press ^ button, then press OFF button.
2. Press +, =buttons and confirm that the Optical pick-up
moves smoothly from the innermost to outermost circumference
and back smoothly and with no catching or abnormal noises. (Can-
cellation of BTL mute)
+ : Optical pick-up moves to the outer circumference
= : Optical pick-up moves to the inner circumference
r
 Focus Search Check
1. Press ^ button. (Focus search operation is performed continu-
ously.)
2. Look at the Optical pick-up objective lens and confirm that it moves
up and down smoothly, with no catching or abnormal noises.
3. Press 
π
 button.
Confirm that focus search operation stops. If it does not , press 
π
button again longer.
Note 
: When the malfunction is occurred by mis-passing
other buttons, turn off the power and check again
from making the test mode.
How to put the Set into Test Mode
1. Short-circuit following portion (IC801 @¢ pin) on the MAIN board.
2. Turn the POWER ON.
TEST MODE
terminal
[ MAIN BOARD ]
How to release Test Mode
1. Turn the POWER OFF.
2. Open the short-circuit to release test mode.
– 11 –
6. Adjust RV701 so that the oscilloscope waveform is as shown in
the figure below (eye pattern).
A good eye pattern means that the diamond shape (
) in the center
of the waveform can be clearly distinguished.
7. Release test mode after adjustment is completed.
r
 RF signal reference waveform (eye pattern)
1.1 
±
 0.2V
VOLT/DIV : 0.2V
TIME/DIV : 500ns  
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
 
+
oscilloscope
(DC range)
TP (RFO)
TP (VC)
[ MAIN BOARD ]
Adjustment Location : Main board (page 13)
Focus/Tracking Gain Adjustment
A frequency responce analyzer is necessary in order to perform this
adjustment exactly.
However, this gain has a margin, so even if it is slightly off, there is
no problem. Therefore, do not perform this adjustment.
Focus/tracking gain determines the pick-up follow-up (vertical and
horizontal) relative to mechanical noise and mechanical shock when
the 2-axis device operate.
However, as these reciprocate, the adjustment is at the point where
both are satisfied.
r
 When gain is raised, the noise when the 2-axis device operates
increases.
r
 When gain is lowered, mechanical shock and skipping occurs
more easily.
r
 When gain adjustment is off, the symptoms below appear.
E-F Balance Adjustment
This adjustment is to be done when the optical pick-up block is re-
placed.
Adjustment Procedure :
1. Connect the oscilloscope between TP (VC) and TP (TO) on main
board.
2. Put the set into test mode.
3. optical pick-up setting  to the center by + or = button push-
ing.
4. Insert disc (YEDS-18) and press ^ button.
5. Adjust RV703 so that the oscilloscope traveres waveform is sym-
metrical, as shown in the figure below.
6. Release test mode after adjustment is completed.
   
A          
0V
B
C
VOLT / DIV : 1V
TIME / DIV :1ms
A = B
C = 350mV 
±
 120mV
+
-
oscilloscope
(DC range)
TP (TO)
TP (VC)
[ MAIN BOARD ]
Adjustment Location : Main board (page 13)
Focus Bias Adjustment
This adjustment is to be done when the optical pick-up block is re-
placed.
Adjustment procedure :
1. Connect oscilloscope to test point TP (VC) and TP (RFO) on main
board.
2. Put the set into test mode.
3. Optical pick-up setting to the center by + or = button push-
ing.
4. Insert disc (YEDS-18) and press CD PLAY ^ button.
5. Press the ^ button.  (Tracking servo ON)
– 12 –
5. Connect oscilloscope to TP(TO) and TP(VC) on MAIN board.
6. Adjust RV704 on digital board so that the waveform is as shown
in the figure below. (Tracking Gain Adjustment)
7. Release test mode after adjustment is completed.
0V
low tracking gain
high tracking gain
high fundamental wave
than for low gain
high focus gain
0V
0V
VOLT / DIV : 1V
TIME / DIV : 2ms
VOLT / DIV : 1V
TIME / DIV : 2ms
VOLT / DIV : 1V
TIME / DIV : 2ms
r
 
Incorrect Examples (fundamental wave appears)
+
oscillcope
(DC range)
TP (TO)
TP (FO)
TP (VC)
[ MAIN BOARD ]
Adjustment Location : Main board (page 13)
The time until music starts becomes
 longer for STOP 
→ 
^
 
button or 
automatic selection.
( =, + buttons pressed.)
(Normally takes about 2 seconds.)
r  
Music does not start and disc
 continues to rotate for STOP 
→ 
^
 
button or automatic selection.
(  =, + buttons pressed.)
r    
Sound is interrupted during PLAY. 
Or time counter display stops
 progressing.
r   
More noise during 2-axis device
 operation.
Symptoms
Gain
Focus
Tracking
low   
  low or high
           low
           low
high
            high
The following is a simple adjustment method.
– Primary Adjustment –
Note : 
Since exact adjustment cannot be performed, remember the
positions of the controls before performing the adjustment.If
the positions after the primary adjustment are only a little
different, return the controls to the original position.
Procedure :
1. Keep the set horizontal.
If the set is not horizontal, this adjustment cannot be performed
due to the gravity against the 2-axis device.
2. Insert disc (YEDS-18) and press ^ button.
3. Connect oscilloscope to TP(FO) and TP (VC) on MAIN board.
4. Adjustment RV702 on MAIN board so that the waveform is as
shown in the figure below. (focus gain adjustment)
100mV
0V
200mV
low focus gain
high focus gain
0V
75mV
0V
VOLT / DIV : 100mV
TIME / DIV : 2ms
VOLT / DIV : 100mV
TIME / DIV : 2ms
VOLT / DIV : 100mV
TIME / DIV : 2ms
r
 
Incorrect Examples (DC level changes more than on adjusted
   waveform)
Page of 28
Display

Click on the first or last page to see other CFD-6 service manuals if exist.