Sony CDP-XE530 Service Manual ▷ View online

— 9 —
4-3. AGING MODE
This unit is equipped with an aging mode to check operations of the
mechanism deck.
• When faults occur:
Aging stops, and the state when aging stopped is displayed on the
fluorescent display tube.
• When no fault has occurred:
Aging is continued repeatedly.
Aging method 1
(When using the aging mode remote controller (J-2501-123-A)):
1.
Press the  
U  button and turn ON the power.
2.
Set the disc on the tray.
3.
Press the  AGING START  button of the aging remote controller.
4.
Aging starts and the message shown in Fig. 1 is displayed on
the fluorescent display tube.
5.
To end, press the  
U  button.
Aging method 2 (When no aging mode remote controller):
1.
Press the  
U button and turn ON the power.
2.
Set the disc on the tray.
3.
Press the  
§ OPEN/CLOSE  button,  p  button, and  MUSIC
SCAN  button at the same time. (If these buttons are not pressed
at the same time, nothing performs.)
4.
Aging starts and the message shown in Fig. 1 is displayed on
the fluorescent display tube.
5.
To end, press the  
U  button.
Fig. 1 Message in Aging Mode
0
1
2
3
4
5
6
Load in
Access to TOC
Access to last track
Playback of last track
(3 seconds)
Access to first track
Playback of first track
(3 seconds)
Load out
AGING-0
AGING-1
AGING-2
Counter display
AGING-4
Counter display
AGING-6
ERROR-0
ERROR-1
ERROR-2
ERROR-3
ERROR-4
ERROR-5
ERROR-6
Code
No.
State
Display when
normal
Display when
abnormal
[ MAIN BOARD ] – Component Side –
JW613 (ADJ)
CN621
JW617 (AFADJ)
— 10 —
Procedure :
1.
Connect oscilloscpe to test point TP (TE) on BD board.
2.
Turn Power switch on.
3.
Put disc (YEDS-18) in to play the number five track.
4.
Press the  
P  (Pause) button. (Becomes the 1 track jump mode)
5.
Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
SECTION 5
ELECTRICAL BLOCK CHECKING
Note:
1.
CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10M
 impedance.
4.
Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the
following checks.
S Curve Check (With general remote commander)
Procedure :
1.
Connect oscilloscope to test point TP (FE) on BD board.
2.
Connect the test point JW613 (ADJ) on MAIN board to the
ground with a lead wire.
3.
Turn Power switch on.
4.
Put disc (YEDS-18) in press  
·  (play) button.
5.
When the  !¡  button of the remote commander is pressed, the
S curve will be output continuously.
6.
Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 3
Vp-p.
S-curve waveform
7.
After check, remove the lead wire connected in step 2.
Note :
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
oscilloscope
BD board
TP (FE)
TP (VC)
+ 1.5
– 1
symmetry
A
B
Within 3        Vp-p
+ 1.5
– 1
oscilloscope
BD board
TP (FE)
TP (VC)
symmetry
S-curve waveform
A
B
Within 3.8 
±
 1.1 Vp-p
S Curve Check (Without general remote commander)
Procedure :
1.
Connect oscilloscope to test point TP (FE) on BD board.
2.
Connect between test point TP (FEI) and TP (VC) by lead wire.
3.
Connect both ends of TP R151 of the BD board to the lead
wire.
4.
Turn Power switch on.
5.
Put disc (YEDS-18) in and actuate the focus search. (actuate
the focus search when disc table is moving in and out.)
6.
Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 3.8 ±
1 Vp-p.
7.
After check, remove the lead wire connected in step 2 and 3.
Note :
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.2 
±
 0.2 Vp-p
oscilloscope
BD board
TP (TE)
TP (VC)
oscilloscope
BD board
TP (RF)
TP (VC)
Procedure :
1.
Connect oscilloscope to test point TP (RF) on BD board.
2.
Turn Power switch on.
3.
Put disc (YEDS-18) in to play the number five track.
4.
Confirm that oscilloscope waveform is clear and check RF
signal level is correct or not.
Note:
A clear RF signal waveform means that the shape “
” can be clearly
distinguished at the center of the waveform.
       RF signal waveform
E-F Balance (1 Track Jump) Check
(Without general remote commander)
— 11 —
E-F Balance Check (With general remote commander)
Procedure :
1.
Connect the test point JW613 (ADJ) on MAIN board to the
ground with a lead wire on main board.
2.
Connect oscilloscpe to test point TP (TE) on BD board.
3.
Turn the Power switch on to set the ADJ mode.
4.
Put disc (YEDS-18) in to play the number five track.
5.
Press the 4 button. (The tracking servo and the sledding servo
are turned OFF.)
6.
Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
Traverse waveform
oscilloscope
BD board
TP (TE)
TP (VC)
[ BD BOARD ] – Side A –
Adjustment Location :
[ MAIN BOARD ] – Component Side –
0V
level :  1.3 
±
 0.6 Vp-p
A (DC voltage)
Center of the waveform
B
7.
Press the 9 button. (The tracking servo and sledding servo
are turned ON.) Confirm the C (DC voltage) is almost equal to
the A (DC voltage) is step 6.
Traverse waveform
0V
C (DC 
voltage)
Tracking servo
Sledding servo 
OFF
Tracking servo
Sledding servo
        ON
8.
Disconnect the lead wire of JW613 (ADJ) connected in step 1.
CN102
IC101
TP(FEI)
TP(VC)
TP(IOP)
TP(RF)
TP(TE)
TP(FE)
TP
(R151)
0V
level : 1.3       Vp-p
A (DC voltage)
Center of the waveform
B
symmetry
+ 0.7
– 0.6
     1 track jump waveform
JW613 (ADJ)
CN621
JW617 (AFADJ)
— 12 —
SECTION  6
DIAGRAMS
6-1. CIRCUIT BOARDS LOCATION
KEY board
DISPLAY board
HP board
MAIN board
BD board
LOADING board
POWER SW board
Page of 34