9
CDP-XE270/XE370
SECTION  4
TEST  MODE
AGING MODE
Procedure:
1. While pressing the both
x
 and 
[CLEAR]
 buttons, turn the
power on.
2. Tray open-close aging is performed.
3. Press the 
[TIME]
 button to display time for open-close on the
fluorescent indicator tube.
4. To release the mode, press the 
[POWER]
 button to turn OFF
the power.
CHECK MODE
Procedure:
1. Press the 
[POWER]
 button to turn ON the power
2. Press the 
[    OPEN/CLOSE]
 button and insert the disc.
3. Press the 
[POWER]
 button to turn OFF the power.
4. While pressing the both 
[PLAY MODE]
 and 
[     ]
 buttons, turn
the power on .
5. CD starts playing, and every time the 
[TIME]
 button is pressed,
RFDC and OFFSET are changed over.
6. To release the mode, press the 
[POWER]
 button to turn OFF
the power.
ADJ MODE
Procedure:
1. Press the 
[POWER]
 button to turn ON the power
2. Press the 
[    OPEN/CLOSE]
 button and insert the disc.
3. Press the 
[POWER]
 button to turn OFF the power.
4. Short-circuit the test TP (ADJ) of the DISPLAY board and
ground with a lead wire.
5. Press the 
[POWER]
 button to turn ON the power and CD plays
the second track.
6. To release the mode, press the 
[POWER]
 button to turn OFF
the power.
7. Open-circuit the test TP (ADJ) of the DISPLAY board and
ground with a lead wire.
AFADJ MODE (KEY AND FLUORESCENT INDICA-
TOR TUBE DISPLAY CHECK MODE)
Procedure:
1. Short-circuit the test TP (AFADJ) of the DISPLAY board and
ground with a lead wire.
2. Press the 
[POWER]
 button to turn ON the power.
The whole fluorescent indicator tube lights up.
3. All buttons have individual button numbers.
When a button is pressed, the button number is counted up
and displayed.
When remote controller signals are received, “RM 
**” will be
displayed.
(
** are the numbers corresponding to the remote controller
buttons.) (CDP-CE370 only)
4. To release the mode, press the 
[POWER]
 button to turn OFF
the power.
5. Open-circuit the test TP (AFADJ) of the DISPLAY board and
ground with a lead wire.
Buttons and Corresponding Button Numbers
Button
Button Number or Display
H (PLAY)
Partical lighting 1
X (PAUSE)
02
x (STOP)
Partical lighting 2
lAMSL (button)
04
m
05
M
06
TIME
07
PLAY MODE
08
CLEAR
09
REPEAT
10
A OPEN/CLOSE
All lit
lAMSL (knob)
When rotated clockwise: The music calendar
numerals light up in ascending order.
When rotated counterclockwise: The music
calendar numerals light up in descending
order.
Count up display
Displays button number
1
0
SEC
MIN
Partial lighting 1
2
4
6
8
10
12
14
16
18
20
Partial lighting 2
[   ]
A
H
A
10
CDP-XE270/XE370
Checking Location:
– DISPLAY BOARD (Conductor Side) –
TP 
(ADJ)
TP 
(AFADJ)
(GND)
11
CDP-XE270/XE370
Ver 1.1  2001.07
Note:
1. CD Block is basically designed to operate without adjustment. There-
fore, check each item in order given.
2. Use PATD-012 disc (4-225-203-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S Curve Check
Connection:
Procedure:
1.
Connect an oscilloscope to test point TP (FE1) and TP (VC)
on the BD board.
2.
Turn the power on and insert the disc (PATD-012).
3.
Turn the power off and enter the ADJ mode. (Refer to 4. Test
Mode)
4.
Turn the power on to playback the second track and press the
x
button to stop playing back.
5.
Press the  
[REPEAT]
 button. (The object lens moves up and
down)
6.
Confirm the oscilloscope waveform (S-curve) is symmetrical
between A and B. And check peak to peak level within 2 ± 1
Vp-p.
S-curve waveform
Note:
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
Checking Location: BD board (See page 12)
RFDC Level Check
Connection:
+
BD board
TP (FE1)
TP (VC)
oscilloscope
A
B
symmetry
within 2 
±
 1 Vp-p
+
BD board
TP (RFDC)
TP (VC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns 
level: 1.15 
±
 0.35 Vp-p
VC
Procedure:
1.
Connect an oscilloscope to test point TP (RFDC) and TP (VC)
on the BD board.
2.
Turn the power on and insert the disc (PATD-012).
3.
Turn the power off and enter the ADJ mode. (Refer to 4. Test
Mode)
4.
Turn the power on to playback the second track.
5.
Confirm that oscilloscope waveform is clear and check RFDC
signal level is correct or not.
Note:
A clear RFDC signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
       RFDC signal waveform
Checking Location: BD board (See page 12)
RFAC Level Check
Connection:
Procedure:
1.
Connect an oscilloscope to test point TP (RFAC) and TP (VC)
on the BD board.
2.
Turn the power on.
3.
Turn the power off and enter the ADJ mode. (Refer to 4. Test
Mode)
4.
Turn the power on to playback the second track.
5.
Confirm that oscilloscope waveform is clear and check RFAC
signal level is correct or not.
Note:
A clear RFAC signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
       RFAC signal waveform
Checking Location: BD board (See page 12)
+
BD board
TP (RFAC)
TP (VC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns 
level: 1.35 
±
 0.4 Vp-p
SECTION  5
ELECTRICAL  CHECKS
12
CDP-XE270/XE370
Ver 1.1 2001.07
E-F Balance Check
Connection:
Procedure:
1.
Connect an oscilloscpe to test point TP (TE1) and TP (VC) on
the BD board.
2.
Turn the power on.
3.
Put the disc (PATD-012) in to playback the number two track.
4.
Press the 
[TIME]
 button.  (The tracking servo and the sledding
servo are turned OFF)
5.
Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
Traverse Waveform
6.
Press the 
[TIME]
 button. (The tracking servo and sledding servo
are turned ON)
Confirm the C (DC voltage) is almost equal to the A (DC
voltage) is step 5.
Traverse Waveform
Checking Location: BD board
+
BD board
TP (TE1)
TP (VC)
oscilloscope
0V
B
level: 1.15 
±
 0.5 Vp-p
Center of 
the waveform
A (DC 
voltage)
0V
Tracking servo
Sled servo
ON
C (DC 
voltage)
Tracking servo
Sled servo
OFF
Checking Location:
– BD BOARD (Conductor Side) –
TP 
(RFDC)
TP
 (FE1)
TP
 (VC)
IC131
IC150
IC101
TP
 (TE1)
TP 
(RFAC)
Page of 35