DOWNLOAD Sony CDP-CX255 / CDP-CX70ES / CDP-CX88ES Service Manual ↓ Size: 1.37 MB | Pages: 50 in PDF or view online for FREE

Model
CDP-CX255 CDP-CX70ES CDP-CX88ES
Pages
50
Size
1.37 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
cdp-cx255-cdp-cx70es-cdp-cx88es.pdf
Date

Sony CDP-CX255 / CDP-CX70ES / CDP-CX88ES Service Manual ▷ View online

— 21 —
GUIDE (DISC T) ALIGNMENT
(2) Check that the state is as shown in the
figure.
(4) Move the holder (guide T) with a tapering screwdriver, and
set the position of the guide (disc T) to A:B=1:1.
(3) Loosen the fixed screw by about 60 
°
.
Guide (disc T)
Cam
Holder (guide T)
Fixed screw
Disc
Guide (disc T)
Disc
Tapering screwdriver
Cam
Guide (disc T)
(1) Rotate the cam and adjust to the posi-
tion shown in the figure.
B
A
Holder
(guide T)
Holder (guide T)
— 22 —
HOLDER (DISC A2) ALIGNMENT
(1) Rotate the cam and adjust to the position
shown in the figure.
(3) After applying suitable locking compound to the         part, rotate the thrust screw until the holder (Disc A2) comes to the center of the disc.
Cam
Thrust
screw
Cam
Disc
Holder (disc A2)
Thrust screw
Holder (disc A2)
(2) Check that the state is as shown in the
figure.
0 – 1 mm
Holder (disc A2)
Disc
1234
1234
— 23 —
Fixed screw
Tapering screwdriver
Luminus board
Bracket (sensor)
Lever (stopper) assembly
Disc table
(2) Check that the lever (stopper) assem-
bly secures the disc table as shown in
the figure.
(1) Rotate the cam and adjust to the position
shown in the figure.
Cam
Bracket (sensor)
Table assembly
Swing
Cam
PAUSE button
PLAY button
(3) Loosen the fixed screw by 60
°
 to 90
°
, and use a tapering screwdriver to adjust the screw as shown in the figure.
Move the bracket (sensor) with the tapering screwdriver little by little, and fix the fixed screw at where the play button's LED (green) is
switched to the pause button's LED (orange) (or its reverse).
SENSOR ALIGNMENT
Perform this adjustment after the “holder (disc A2) adjustment”.
If the disc table swings to the left and right just before the disc is
chucked, perform the following adjustment.
(4) Moving the disc table right and left with a hand after the screw
is fixed, the table will move by the play of a disc table. If the
LEDs light up alternately, the adjustment will be performed cor-
rectly.
LEVER (stopper)
assembly
— 24 —
(1) Rotate the cam and adjust to the position
shown in the figure.
(2) Check that the state is as shown
in the figure.
(3) Remove the Magnet assembly.
Cam
Magnet assembly
PULLY AND DISC CENTER HOLE ALIGNMENT
Base unit
Cam
Bracket
(BU adjustment)
Magnet assembly
Disc pulley
Disc hole
A
B
Disc
Note: The disc should not
be fixed.
Base unit
Holer (disc A2)
Fixed screw
Bracket
(BU adjustment)
Tapering screwdriver
0.5 – 2mm
(4) Loosen the fixed screw by 60
°
 to 90
°
, and move and adjust the
bracket (BU adjustment) up and down using a tapering screw-
driver so that the positions of the disc hole and disc pulley be-
come A=B or between A:B=2:1 and 1:2.