SECTION 4
TEST MODE
DISPLAY CHECK MODE
With the power turned off (standby state), press the POWER button
while pressing the 
P (pause) button.
All FL segments and grids light up together with the 
· (play),
P (pause), and standby LEDs.
At the same time, the GROUP LEDs are scanned one by one.
Note: To exit this mode, press the POWER button.
ADJ MODE
1. Turn ON the power of the unit, set disc to disc table, and per-
form chucking.
2. Disconnect the power supply plug from the outlet.
3. To set ADJ mode, connect the test point (TP301: ADJ) of the
MAIN board to Ground, and connect the power supply plug to
the outlet.
The power will turn on automatically, and the first track will be
played.
In this mode, table rotation and loading operations are not performed
because it is taken that the disc has already been chucked.
Note: The same operations are also performed in the following when
the test point (TP301: ADJ) is connected to Ground after turn-
ing on the power.
• Direct search (movement of sledding motor) is not performed dur-
ing accessing
• Ignored even when GFS becomes L
• Ignored even when the Q data cannot be read
• Focus gain does not decrease
• Spindle gain does not decrease
• Servo related settings can be set manually and checked (Refer to
ADJ Mode Special Functions Table)
ADJ Mode Special Functions Table
(The buttons shown with (  ) function by using the sup-
plied remote commander only)
Button
Function
GROUP 1 (1)
GROUP 2 (2)
GROUP 3 (3)
GROUP 4 (4)
GROUP 5 (5)
GROUP 6 (6)
GROUP 7 (7)
GROUP 8 (8)
(9)
(10/0)
CHECK
CLEAR
Increases the focus bias in 8 steps.
Sets the focus bias in the middle of aliasing.
Turns off the tracking and sledding servo
Returns the auto gain to the initial value (30)
Turns off the focus servo
Decreases the focus bias in 8 steps.
Re-adjusts the focus bias
Turns on the tracking and sledding servo
Switches the focus servo gain between normal and down
FG. norm: normal, FG. down: down
Sets the focus bias to 0 (no bias)
Next, displays the jitter measured at the focus bias set
S-curve observation mode
Automatic eccentric measurement
The results of measurement is displayed in 
µ
m directly.
Servo average display
Displays VC, FE, RF, TE and traverse in hexadecimal
numbers
Focus bias display
Each time this is pressed, the focus bias is switched
between 1 and 2
(1)
Bias actually set     Optimum bias     Minimum jitter
(2)
U:Upper aliasing bias     L:Lower aliasing bias
Auto gain display
Displays focus, tracking, sledding in hexadecimal
numbers
PROGRAM
SHUFFLE
CONTINUE
KEY AND FLUORESCENT DISPLAY TUBE CHECK
MODE
1. Connect the test point (TP302:AFADJ) of the main board to the
GND, and insert the power plug to the outlet to set this mode.
First, the external SRAM is checked, and if abnormal, “SRAM
NG” is displayed.
If OK, the following steps are performed.
* Fluorescent Display Tube Check Mode
The whole fluorescent display tube lights up when the con-
nection in step 1 is made.
* Key Check Mode
This mode is set when a button is pressed after the whole fluo-
rescent display tube lights.
All buttons have a button number.
When a button is pressed, the counter display is counted up,
and the number of that button is displayed.
However, the counter display will only count up to 24, but the
number of buttons pressed will always be displayed.
24
0
0
Counter display
Button number display
POWER
GROUP 4
GROUP 3
GROUP 2
GROUP 1
GROUP 5
GROUP 6
GROUP 7
ENTER
REPAT
PROGRAM
SHUFFLE
CONTINUE
TIME/TEXT
GROUP 8
MEMO SEARCH
INPUT
±
CHECK
CLEAR
·
P
p
TIMER
Button No. Displayed
Button
0
1
2
3
4
5
6
7
9
10
11
12
13
14
15
21
22
23
24
25
26
All lit (LED lit)
Partial lighting 1 (LED lit)
Partial lighting 2
When the TIMER switch is set to OFF, “0” is dis-
played at the top right of the fluorescent display tube.
When set to ON, “1” is displayed.lit while pressed
(grid check).)
• When the jog dial is rotated to the right, the
GROUP LEDs light up in the order of 1
n2..8n1.
• When the jog dial is rotated to the left, the GROUP
LEDs light up in the order of 8
n7..1n8.
DISC/
CHARACTER
— 18 —
The standby LED lights up when the door switch is shut.
Partial lighting 1
A B C D E F G
0
Partial lighting 2
0
[ MAIN BOARD ] — Component Side —
TP302
AFADJ
TP301
ADJ
IC201
CN302
CN303
CN301
AGING MODE
Aging Mode
• Mode which repeatedly changes and plays back discs automati-
cally in the unit.
• It will repeat aging as long as no errors occur.
• If an error occurs during aging, it will stop all servos, motors, etc.
instantaneously, display the error number, and stop operations.
However, the stopping conditions differ according to whether the
unit is equipped with the “self-protection function during errors”
described later.
The function serves to maintain the state of the unit when errors
occur.
Sequence of Aging Mode
$
$
$
1. Disc change
2. Load in
3. TOC read
4. Access of last track
5. 3 second playback
6. Access of first track
7. 3 second playback
8. Load out
$
$
$
$
$
$
Order of Disc Change
 (1 cycle takes 3 minutes)
$
$
$
1. No. 40
2. No. 120
3. No. 80
4. No. 200
5. No. 160
$
$
$
Special Functions in Aging Mode
1 Disc setting mode:
5 discs are set before setting the aging mode. This mode makes
the setting of these discs more easy.
2 Self protection function during errors:
Function which voluntarily corrects errors which occur during
normal operations by retries.
If this function is not provided, all operations will be stopped
without retiring. It is suitable for checking errors with low re-
producibility.
If this function is provided, and errors can be corrected by re-
tries, aging will be continued without stopping.
3 Aging cycle count function:
Functions which displays the number of agings carried out on
the Fluorescent indicator tube  in numbers. One aging cycle con-
sists of five discs.
number of agings
1DISC
CD1
DISC
2
*
DISC-40
*
— 19 —
Aging Method
1. Change the  COMMAND MODE  switch (S501) on set to
 CD1 .
2. Turn ON the power of the unit. Open the front cover.
3. Press the AGING START button of the remote commander for
aging mode (J-2501-123-A).
4. When the disc set mode is set, the 
· and P LEDs blink.
5. Rotate the JOG dial. The slits (No. 40, 80, 120, 160, 200) for
setting the discs will come forward. Insert the discs into these
slits. Do not set the discs in other slits.
6. Set whether the self-protection function during errors is equipped
with the unit. Press the REPEAT button. If “REPEAT” is dis-
played on the Fluorescent indicator tube, it means the function
is provided. If “REPEAT” is not displayed, it means the func-
tion is not provided.
7. Press the 
· button.
8. The 
· LED blinks, the aging mode is set, and aging is started.
9. The aging cycle lasts 3 minutes. If errors occur during aging, the
error number will be displayed on the Fluorescent indicator tube.
(Refer to the following table for the details of the errors.)
10.Aging will be repeated as long as no errors occur.
11.After each aging cycle, the number displayed on the Fluores-
cent indicator tube will increase.
12.To end aging, press the POWER button
Error Display
1 2 0
E r r 0 1
  
  
Disc number
Error code
Error code
Err 01
Err 02
Err 03
Err 04
Err 05
Err 06
Err *1
Err *2
Err *3
Err *4
Err *5
Err *6
Err *7
Code number
Name
DISC sensor check 1
DISC sensor check 2
Table operation check 1
Table operation check 2
Loading operation check 1
Loading operation check 2
BU related check 1
BU related check 2
BU related check 3
BU related check 4
BU related check 5
BU related check 6
BU related check 7
Contents
No disc in the specified slit
Disc in other slits
Table motor current over
No table sensor input
Load in timeover
Load out timeover
Access timeover
High speed search NG
Q data read error
BU operation (from focus search to until signal can be read) timeover
GFS monitor error
Focus cannot be imposed by focus search
Auto focus bias adjustment cannot be performed
The * numbers mean the following according to the state of the unit during aging
2 : From chucking to end of TOC read
3 : From end of TOC read to end of last track playback
4 : From end of last track playback to end of first track playback
— 20 —
SECTION 5
ADJUSTMENTS
5-1. MECHANICAL ADJUSTMENT
Perform the following steps before carrying out adjustments.
1. Turn ON the power of the unit, set disc to disc table No. 92, and
perform chucking.
2. Turn OFF the power.
3. Remove the case.
4. While pressing the STOP button, turn ON the POWER button.
The test mode is set.
5. The POWER button LED starts blinking.
(Test mode)
POWER button
STOP button
GROUP 1
button
GROUP 5
button
GROUP 1 button
GROUP 5 button
Cam
Pulley
LED
POWER
NOTE 1: The cam will start rotating when the GROUP 1 or
GROUP 5 button is pressed continuously in the test mode.
NOTE 2: If the power cannot be supplied, the cam can be rotated
by rotating the pulley with your finger.