DOWNLOAD Sony CDP-CA70ES Service Manual ↓ Size: 3.5 MB | Pages: 44 in PDF or view online for FREE

Model
CDP-CA70ES
Pages
44
Size
3.5 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio / S/M CDP-CA70ES 99 US CAN
File
cdp-ca70es.pdf
Date

Sony CDP-CA70ES Service Manual ▷ View online

— 13 —
All lit
1
2 3
4
5
6
7 8
9 10
11 12 13 14 15
16 17 18 19 20
Partial lighting 1
Partial lighting 2
˜
Light alternately
˜
Light alternately
˜
Light alternately
— 14 —
AGING MODE
This unit is equipped with an aging mode to check operations
of the mechanism deck.
• When faults occur:
Aging stops, and the state when aging stopped is displayed on the
fluorescent display tube.
• When no fault has occurred:
Aging is continued repeatedly.
Note: Do not use the test disc when performing aging.
Aging will not be performed properly if discs with tracks
shorter than 4 seconds are used.
Aging method 1
(When using the aging mode remote controller (J-2501-123-A):
1. Set the COMMAND MODE switch to CD1.
2. Press the  
1/u  button and turn ON the power.
3. Set discs on all trays.
(More than two discs if five are not available.)
4. Press the AGING START button of the aging remote controller.
5. Aging starts and the message shown in Fig. 1 is displayed on the
fluorescent display tube.
6. To end, press the  
1/u  button.
Aging method 2
(When no aging mode remote controller):
1. Press the  
1/u  button and turn ON the power.
2. Set discs on all trays.
(More than two discs if five are not available.)
3. Press the  4 button, 0 button, and  DISC SKIP  button in this
order together.
4. Aging starts and the message shown in Fig. 1 is displayed on the
fluorescent display tube.
5. To end, press the  
1/u  button.
Fig. 1 Aging Operations and Their Messages
The discs are selected in the order of DISC 1 n DISC 2 n DISC 3 n DISC 4 n DISC 5 n DISC 1 n .... Empty trays are skipped.
Code No.
State
1
2
3
4
5
6
7
8
9
A
0
TOC reading
Accessing last track
Playing back last track (3 seconds)
EX-CHANGE (Tray opened while chucking)
DISC SKIP (Disc tray rotated)
CLOSE (Tray closed)
Accessing first track
Playing back first track (3 seconds)
OPEN (Tray opened)
DISC SKIP (Disc tray rotated, and next disc was selected)
CLOSE (Tray closed)
Display when Normal
AGING 1
AGING 2
Counter display
AGING 4
AGING 5
AGING 6
AGING 7
Counter display
AGING 9
AGING A
AGING 0
Display when Abnormal
AGING NG1
AGING NG2
AGING NG3
AGING NG4
AGING NG5
AGING NG6
AGING NG7
AGING NG8
AGING NG9
AGING NGA
AGING NG0
— 15 —
SECTION 5
ELECTRICAL BLOCK CHECKING
Note:
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent when
the signal level is low than specified value with the following
checks.
S Curve Check
Procedure :
1. Connect oscilloscope to test point TP (FE1) on BD board.
2. Connect between test point TP (FE1) and TP (VC) by lead wire.
3. Connect both ends of TP R151 of the BD board to the lead wire.
4. Turn ON the power.
5. Put disc (YEDS-18) in and actuate the focus search. (actuate the
focus search when disc table is moving in and out.)
6. Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 4.5 ± 1
Vp-p.
S-curve waveform
7. After check, remove the lead wire connected in step 2 and 3.
Note :
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
Procedure :
1. Connect oscilloscope to test point TP (RF) on BD board.
2. Turn ON the power.
3. Put disc (YEDS-18) in to play the number five track.
4. Confirm that oscilloscope waveform is clear and check RF signal
level is correct or not.
Note:
A clear RF signal waveform means that the shape “
” can be clearly
distinguished at the center of the waveform.
       RF signal waveform
E-F Balance (1 Track Jump) Check
(without general remote commander)
Procedure :
1. Connect oscilloscpe to test point TP (TE) on BD board.
2. Turn ON the power.
3. Put disc (YEDS-18) in to play the number five track.
4. Press the  
P  (Pause) button. (Becomes the 1 track jump mode)
5. Check the level B of the oscilliscope's waveform and the A (DC
voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
     1 track jump waveform
E-F Balance Check (With general remote commander)
Procedure :
1. Turn ON the power, put disc (YEDS-18), turn OFF the power.
2. Connect the test point TP2 (ADJ) on MAIN board to the ground
with a lead wire.
3. Connect oscilloscope to test point TP (TE) on BD board.
4. Turn the Power switch on to set the ADJ mode, automaticaly
play the number five track.
5. Press the 3 button. (The tracking servo and the sledding servo
are turned OFF.)
oscilloscope
BD board
TP (FE1)
TP (VC)
symmetry
A
B
Within 4.5 
±
 1 Vp-p
oscilloscope
BD board
TP (RF)
TP (VC)
oscilloscope
BD board
TP (TE)
TP (VC)
0V
level : 1.3         Vp-p
A (DC voltage)
Center of the waveform
B
symmetry
+ 0.7
– 0.6
oscilloscope
BD board
TP (TE)
TP (VC)
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 1.2 
±
 0.2 Vp-p
— 16 —
6.
Check the level B of the oscilliscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
Traverse waveform
7.
Press the 8 button. (The tracking servo and sledding servo
are turned ON.) Confirm the C (DC voltage) is almost equal to
the A (DC voltage) is step 6.
Traverse waveform
8.
Disconnect the lead wire of TP2 (ADJ) connected in step 2.
Adjustment Location :
[BD BOARD] – SIDE A –
[MAIN BOARD] – CONDUCTOR SIDE –
0V
level : 1.3         mVp-p
A (DC voltage)
Center of the waveform
B
+ 0.7
– 0.6
0V
C (DC 
voltage)
Tracking servo
Sledding servo
        OFF
Tracking servo
Sledding servo
        ON
CN102
IC101
TP(FE2)
TP(VC)
TP(IOP)
TP(RF)
TP(TE)
TP(FE1)
IC501