Model
BDV-HZ970W BDV-IZ1000W HBD-HZ970W HBD-IZ1000W
Pages
127
Size
10 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
bdv-hz970w-bdv-iz1000w-hbd-hz970w-hbd-iz1000w.pdf
Date

Sony BDV-HZ970W / BDV-IZ1000W / HBD-HZ970W / HBD-IZ1000W Service Manual ▷ View online

HBD-HZ970W/IZ1000W
17
2-13.  BD  DRIVE (BPX-5)
qj MB-135 board block
6 saranet cushion
qh two screws
 (BVTP3 
u 6)
qf two screws (BV3)
qg three screws
 (BVTP3 
u 6)
qs connector (CN602)
1 connector (CN303)
3 LAN connector (CN1201)
qa connector (CN601)
2 connector (CN304)
8 flexible flat cable (45 pin)  
(CN1401)
5 shield flexible flat cable
 (CN701)
9 flexible flat cable (9 pin)  
 (CN2460)
0 flexible flat cable (5 pin)  
 (CN2470)
4 wire (flat type) (7 core)  
 (CN1001)
7 wire (flat type) (18 core)  
 (CN902)
qd wire (flat type) (27 core)  
 (CN504)
w; sound sheet
qk four screws (BV3)
ql
wa BD drive (BPX-5)
HBD-HZ970W/IZ1000W
18
2-14.  OPTICAL  PICK-UP  BLOCK (KEM-460AAA),  WIRE (FLAT TYPE)
1 two screws 
 (BVTP 
2.6)
7 two float screws (S)
qa insulator
5 Insert the thin 
wire (clip etc.).
qa insulator
qa insulator
qs optical pick-up block 
 (KEM-460AAA)
qa insulator
qd two non-halogene tapes
qf wire (flat type) (5 pin)
ql wire (flat type) 
 (45 
pin)
qk wire (flat type) 
 (9 
pin)
loading assy (D)
qj FFC holder (rear)
2 two claws
6
8
9
qh
0
3 two claws
4 chuck holder assy (D)
qg saranet
 cushion 
(LXWXT) 
– Bottom view –
1 wire (flat type)
 (45 
pin)
Under the guide.
Under the guide.
(Fold area)
boss
boss
loading assy (D)
terminal face
terminal face
2 Through the hole.
4 Through the hole.
3 wire (flat type) (9 pin)
5 FFC holder (rear)
7 two claws
7 three
 claws
6
Fold
‡,QVWDOODWLRQRIZLUHIODWW\SHSLQDQGZLUHIODWW\SHSLQ
Note: This illustration sees the loading assy (D) from bottom side.
HBD-HZ970W/IZ1000W
19
SECTION  3
TEST  MODE
COLD  RESET
The cold reset clears data except BD/DVD data stored in the RAM 
to initial conditions. Execute this mode when returning the set to 
the customers.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2. Press the [
x
] and [VOLUME –] buttons simultaneously and 
hold down (around 5 seconds).
3.  The message “COLD RESET” appears on fl uorescent indica-
tor tube, then becomes standby states.
DEMO  MODE
This mode let you lock the disc tray. When this mode is activated, 
the disc will not eject when the [
Z
] button is pressed. The message 
“LOCKED” will be displayed on the fluorescent indicator tube.
Procedure:
1.  Press the [
?/1
] button to turn the power on. 
2.  Press the [FUNCTION] button to select the “BD/DVD”.
3. Press the [
x
] and [
Z
] buttons simultaneously and hold down 
until “DEMO ON” or “DEMO OFF” displayed on the fluores-
cent indicator tube (around 5 seconds).
PANEL TEST
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press button in order of the [RETURN] 
→ [0] → [0] → [1] 
→ [SUBTITLE] on the remote commander (Make the interval 
when each button is pressed within two seconds).
3. All segments in fl uorescent indicator tube are lighted up. And 
half segments in fl uorescent indicator tube are lighted up, oth-
ers half segments in fl uorescent indicator tube are lighted up, 
then all segments in fl uorescent indicator tube are lighted up. 
This operation is repeated.
4.  When all segments in fl uorescent indicator tube are lighted up 
in the state of step 3, press the [VOLUME +] button on the 
remote commander and model information is displayed on the 
fl uorescent indicator tube.
 
Each time the [VOLUME +] button on the remote commander 
is pressed, the display changes from destination information, 
STR version, SYS version, UI version, BDLIB version, ST 
version, TA version, DSP version, DSPF version, TM version, 
CEC version, HDMI version, SAIR version, PF version in this 
order, and returns to the model information display.
 
Each time the [VOLUME –] button on the remote commander 
is pressed, the version and date are switched.
5.  In the state of step 3, press the [FUNCTION] button on the 
remote commander and “K 0” is displayed on the fluorescent 
indicator tube.
 
“K 0” value increases whenever a button on the set is pressed. 
However, once a button has been pressed, it is no longed taken 
into account.
 
All buttons on the set are pressed, “OK” and “K 7” are alter-
nately displayed on the fluorescent indicator tube.
6.  To release from this mode, press the [
?/1
] button.
AMP  TEST
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press button in order of the [RETURN] 
→ [0] → [1] → [1] 
→ [SUBTITLE] on the remote commander (Make the interval 
when each button is pressed within two seconds).
3.  The message “MEASURE” appears on the fluorescent indica-
tor tube and enter the AMP test mode.
4.   Press the [MUTING] button on the remote commander, “VOL 
N” (The change in the volume is usual)/“VOL MSM” (The 
change in the volume is a switch of MIN/1/20/MAX) can be 
switched.
5.   Press the [SUBTITLE] button on the remote commander, the 
message “VACS ON” or “VACS OFF” appears on the fl uores-
cent indicator tube and thus the VACS on/off are changed.
6.   To release from this mode, press the [
?/1
] button.
BD  SERVICE  MODE
Note: The operation in this mode must use a remote commander.
Setting method of the BD service mode:
1.  Press the [
?/1
] button to turn the power on.
2.  Press button in order of the [RETURN] 
→ [0] → [2] → [1] → 
[SUBTITLE] on the remote commander. (Make the interval 
when each button is pressed within two seconds)
3.  Enter the BD service mode.
1. Main Functions
• ErrorLog 
display
 
Display the error log. Displayed contents can also be saved in 
an USB memory device.
• Diag
 
Performs unit test of devices installed on the board.
• Factory 
Initialize
 
Restores the set to its factory settings.
• Network
 
Checks the wired network connection.
•  Version Up (version update)
 Not 
used.
• System 
Information
 
Displays the system information of the set.
 
Displays information such as the software version, drive infor-
mation, etc.
• EMC 
Test 
Mode
 Not 
used.
• Drive
 
Write drive OP data and check drive.
HBD-HZ970W/IZ1000W
20
2. Menu Tree
Service Mode Menu
[1] Diag
[2] Log
[3] Factory Initialize
[4] Network
[5] Version Up
[6] System Information
Service Mode Menu
[1] Diag
[2] Log
[3] Factory Initialize
[4] Network
[5] Version Up
[6] System Information
[7] EMC Test Mode
[8] Drive
Version Up
‡ Not used
System Information
‡ Displays system information
Factory Initialize
‡ 5estores set to factory settings
Log
Displays Error Log
Error Log
‡ Displays error log
Diag
Network
‡ Network diagnosis for wired
Ping
‡ Confirm network connection
Ifconfig
‡ View network status
Device Test
‡ US%D$CIFcon test
Video Test
‡ Video output test
$udio Test
‡ $udio output test
$udio Input Test
‡ $udio Input Test
:ireless L$N Test
‡ Not used
EMC Test Mode
‡ Not used
Drive
‡ Write drive OP data and check drive
Start Initialize for TV
‡ Not used
Start Initialize
‡ Initialize default setting for %Dplayer
‡ Diag Test
Page of 127