Sony BDV-E370 / BDV-E470 / BDV-E570 / BDV-E870 / BDV-T57 / HBD-E370 / HBD-E470 / HBD-E570 / HBD-E870 / HBD-T57 Service Manual ▷ View online
HBD-E370/E470/E570/E870/T57
17
Ver. 1.1
2-10. MAIN BOARD
2-11. AUDIO BOARD
5 wire (flat type) (27 core)
(CN505)
6 wire (flat type) (15 core)
(CN508)
1 screw
(BV3)
3 bracket R
(MB foot)
2
4 connector
(CN904)
7 wire (flat type) (15 core) (CN504) (except AEP, RU, UK)
wire (flat type) (17 core) (CN502) (AEP, RU, UK)
8 wire (flat type) (15 core)
(CN702)
q; wire (flat type) (16 core)
(CN703)
9 wire (flat type) (18 core)
(CN701)
qa four screws
(BV3)
qd two screws
(BV3)
qd six screws
(BV3)
qf MAIN board
qs heat sink
(S-master DDV)
6 three screws (BV3)
7 AUDIO board
3 bracket L (MB foot)
1 screw (BV3)
2
4 connector
(CN17)
5 wire (flat type) (15 core) (CN13) (except AEP, RU, UK)
wire (flat type) (17 core) (CN15) (AEP, RU, UK)
• Abbreviation
RU : Russian model
RU : Russian model
• Abbreviation
RU
RU
: Russian model
HBD-E370/E470/E570/E870/T57
18
2-12. OPTICAL PICK-UP BLOCK (KEM-460AAA), WIRE (FLAT TYPE)
Note: Please prepare the thin wire (clip etc.).
1 two screws
(BVTP 2.6)
7 two float screws (S)
qa insulator
5 Insert the thin
wire (clip etc.).
qa insulator
qa insulator
qs optical pick-up block
(KEM-460AAA)
qa insulator
qd non-halogene tape
qf wire (flat type) (5 core)
qk wire (flat type)
(45 core)
qj wire (flat type)
(9 core)
loading assy (D)
qh ffc holder (rear)
2 two claws
6
8
9
qg
0
3 two claws
4 chuck holder assy (D)
– Bottom view –
1 wire (flat type) (45 core)
Fold.
Under the guide.
Under the guide.
(Fold area)
(Fold area)
boss
boss
loading assy (D)
terminal face
terminal face
2 Through the hole.
4 Through the hole.
3 wire (flat type) (9 core)
5 ffc holder (rear)
7 two claws
7 three claws
6
,QVWDOODWLRQRIZLUHIODWW\SHFRUHDQGZLUHIODWW\SHFRUH
Note: This illustration sees the loading assy (D) from bottom side.
Note: This illustration sees the loading assy (D) from bottom side.
HBD-E370/E470/E570/E870/T57
19
SECTION 3
TEST MODE
COLD RESET
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the set to
the customers.
Procedure:
1. Press the [
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the set to
the customers.
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [
x
] and [VOLUME –] buttons simultaneously and
hold down (around 5 seconds).
3. The message “COLD RESET” appears on fl uorescent indica-
tor tube, then becomes standby states.
DEMO MODE
This mode let you lock the disc tray. When this mode is activated,
the disc will not eject when the [
This mode let you lock the disc tray. When this mode is activated,
the disc will not eject when the [
Z
] button is pressed. The message
“LOCKED” will be displayed on the fluorescent indicator tube.
Procedure:
1. Press the [
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [FUNCTION] button to select the “BD/DVD”.
3. Press the [
3. Press the [
x
] and [
Z
] buttons simultaneously and hold down
until “DEMO ON” or “DEMO OFF” displayed on the fluores-
cent indicator tube (around 5 seconds).
cent indicator tube (around 5 seconds).
S-AIR ID SETTING CHANGE
Procedure:
1. Press the [
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press the [FUNCTION] and [VOLUME +] buttons simultane-
ously and hold down (around 5 seconds).
3. S-AIR ID setting is changed (A
→ B → C → A...).
PANEL TEST
Procedure:
1. Press the [
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press button in order of the [RETURN]
→ [0] → [0] → [1]
→ [SUBTITLE] on the remote commander (Make the interval
when each button is pressed within two seconds).
when each button is pressed within two seconds).
3. All segments in fl uorescent indicator tube are lighted up. And
half segments in fl uorescent indicator tube are lighted up, oth-
ers half segments in fl uorescent indicator tube are lighted up,
then all segments in fl uorescent indicator tube are lighted up.
This operation is repeated.
ers half segments in fl uorescent indicator tube are lighted up,
then all segments in fl uorescent indicator tube are lighted up.
This operation is repeated.
4. When all segments in fl uorescent indicator tube are lighted up
in the state of step 3, press the [VOLUME +] button on the
remote commander and model information is displayed on the
fl uorescent indicator tube.
remote commander and model information is displayed on the
fl uorescent indicator tube.
Each time the [VOLUME +] button on the remote commander
is pressed, the display changes from destination information,
STR version, SYS version, UI version, BDLIB version, ST
version, TA version, DSP version, TM version, CEC version,
SAIR version, PF version in this order, and returns to the mod-
el information display.
is pressed, the display changes from destination information,
STR version, SYS version, UI version, BDLIB version, ST
version, TA version, DSP version, TM version, CEC version,
SAIR version, PF version in this order, and returns to the mod-
el information display.
Each time the [VOLUME –] button on the remote commander
is pressed, the version and date are switched.
is pressed, the version and date are switched.
5. In the state of step 3, press the [FUNCTION] button on the
remote commander and “K 0” is displayed on the fluorescent
indicator tube.
indicator tube.
“K 0” value increases whenever a button on the set is pressed.
However, once a button has been pressed, it is no longed taken
into account.
However, once a button has been pressed, it is no longed taken
into account.
All buttons on the set are pressed, “OK” and “K 7” are alter-
nately displayed on the fluorescent indicator tube.
nately displayed on the fluorescent indicator tube.
6. To release from this mode, press the [
?/1
] button.
AMP TEST
Procedure:
1. Press the [
Procedure:
1. Press the [
?/1
] button to turn the power on.
2. Press button in order of the [RETURN]
→ [0] → [1] → [1]
→ [SUBTITLE] on the remote commander (Make the interval
when each button is pressed within two seconds).
when each button is pressed within two seconds).
3. The message “MEASURE” appears on the fluorescent indica-
tor tube and enter the AMP test mode.
4. Press the [BLUE] button on the remote commander, the state
of D.C.A.C. microphone is displayed on the fl uorescent indica-
tor tube.
tor tube.
*** @@ $$$
***
: Either of “IN”/“NON” is displayed by the state of
detection of the microphone.
@@ : Either of “OK”/“NG” is displayed by the state of
digital audio data input.
$$$
: Microphone input audio data A/D value (0 – 255).
5. Press the [MUTING] button on the remote commander, “VOL
N” (The change in the volume is usual)/“VOL MSM” (The
change in the volume is a switch of MIN/1/20/MAX) can be
switched.
change in the volume is a switch of MIN/1/20/MAX) can be
switched.
6. Press the [SUBTITLE] button on the remote commander, the
message “VACS ON” or “VACS OFF” appears on the fl uores-
cent indicator tube and thus the VACS on/off are changed.
cent indicator tube and thus the VACS on/off are changed.
7. To release from this mode, press the [
?/1
] button.
BD SERVICE MODE
Note: The operation in this mode must use a remote commander.
Setting method of the BD service mode:
1. Press the [
1. Press the [
?/1
] button to turn the power on.
2. Press button in order of the [RETURN]
→ [0] → [2] → [1] →
[SUBTITLE] on the remote commander. (Make the interval
when each button is pressed within two seconds)
when each button is pressed within two seconds)
3. Enter the BD service mode.
1. Main Functions
•
•
ErrorLog display
Display the error log. Displayed contents can also be saved in
an USB memory device.
an USB memory device.
• Diag
Performs unit test of devices installed on the board.
•
Factory Initialize
Restores the set to its factory settings.
• Network
Checks the wired network connection.
•
Version Up (version update)
Not used.
•
System Information
Displays the system information of the set.
Displays information such as the software version, drive infor-
mation, etc.
mation, etc.
•
EMC Test Mode
Not used.
• Drive
Write drive OP data and check drive.
HBD-E370/E470/E570/E870/T57
20
2. Menu Tree
Service Mode Menu
[1] Diag
[2] Log
[3] Factory Initialize
[4] Network
[5] Version Up
[6] System Information
[1] Diag
[2] Log
[3] Factory Initialize
[4] Network
[5] Version Up
[6] System Information
Service Mode Menu
[1] Diag
[2] Log
[3] Factory Initialize
[4] Network
[5] Version Up
[6] System Information
[7] EMC Test Mode
[8] Drive
[1] Diag
[2] Log
[3] Factory Initialize
[4] Network
[5] Version Up
[6] System Information
[7] EMC Test Mode
[8] Drive
Version Up
Not used
Not used
System Information
Displays system information
Displays system information
Factory Initialize
5Hstores set to factory settings
5Hstores set to factory settings
Log
Displays Error Log
Displays Error Log
Error Log
Displays error log
Diag
Network
1Htwork diagnosis for wired
1Htwork diagnosis for wired
Ping
&RQILUPQHWZRUNFRQQHFWLRQ
Ifconfig
View network status
Device Test
86%'$&,)FRQWHVW
86%'$&,)FRQWHVW
Video Test
Video output test
Video output test
$udio Test
$udio output test
$udio output test
$udio Input Test
$XGLR,QSXW7HVW
$XGLR,QSXW7HVW
:LUHOHVV/$17HVW
Not used
Not used
EMC Test Mode
Not used
Not used
Drive
Write drive OP data and check drive
Write drive OP data and check drive
Start Initialize for TV
1RWXVHG
Start Initialize
,QLWLDOL]HGHIDXOWVHWWLQJIRU%'SOD\HU
'LDJ7HVW
Click on the first or last page to see other BDV-E370 / BDV-E470 / BDV-E570 / BDV-E870 / BDV-T57 / HBD-E370 / HBD-E470 / HBD-E570 / HBD-E870 / HBD-T57 service manuals if exist.