Sharp LC-80LE646E (serv.man4) Service Manual ▷ View online
LC-60/70LE740E/RU,741E/S,743E,60LE840E/RU,841E/S,843E,80LE645E/RU,646E/S,648E
5 – 9
4. Basic operation in the Public Mode
5. Operation after “RESET”
Select “RESET” in the PUBLIC Mode, and it operates as follows when it is executed (refer to the basic operation).
• The set contents in the PUBLIC mode are initialized.
• It does not exit the PUBLIC mode.
• If “EXCUTE” is not executed, the content that does RESET is not reflected.
6. Setting items. (* Item names and selective items are expressed in English.)
1) Power ON fixed [POWER ON FIXED]
If the power button is pressed in the ordinary mode in setting to “FIXED_ALL” and “FIXED_BODYKEY”, the caution is displayed for 5 seconds.
* The OSD display is an example.
If another ODS is previously displayed, the status is reset (MENU or similar).
2) Instantaneous current shutdown setting in turning off the power [SHUT DOWN MODE]
Option
“VARIABLE”, “FIXED_ALL”, “FIXED_BODYKEY” or “RCRESPOND” (loop enabled)
Default “VARIABLE”
Function • VARIABLE
Function • VARIABLE
• FIXED_ALL
• FIXED_BODYKEY
• RC RESPOND
• FIXED_BODYKEY
• RC RESPOND
: “POWER/RECEPTION” key on TV unit or remote control is enabled.
: “POWER/RECEPTION” key on TV unit or remote control is disabled.
: Only the “MAIN POWER” key on TV unit is disabled (The remote control is enabled).
: The main unit’s POWER switch toggles between ON and Standby (the same operation by the
remote control).
: “POWER/RECEPTION” key on TV unit or remote control is disabled.
: Only the “MAIN POWER” key on TV unit is disabled (The remote control is enabled).
: The main unit’s POWER switch toggles between ON and Standby (the same operation by the
remote control).
Key disabled when set
other than default
other than default
• OFF TIMER (SLEEP) (*Only when setting to FIXED_ALL)
Remarks
• When selecting to “FIXED_ALL”, function related standby factors (see below) doesn’t work. and not selecting.
OFF TIMER (Sleep)
No operation OFF
No signal OFF (including the power management)
* These items does not exist according to the model.
No operation OFF
No signal OFF (including the power management)
* These items does not exist according to the model.
Option
“NORMAL” or “QUICK”
Default NORMAL
Function
Function
• This function decides whether scanning digital tuner is enabled or disabled when the power is standby.
NORMAL
QUICK
NORMAL
QUICK
: Scanning digital tuner is enabled when the power is standby.
: Scanning digital tuner is disable.
It is possible to put into the standby state instantaneously due to power off input, when the
power is standby.
Immediately, state is a complete standby.
: Scanning digital tuner is disable.
It is possible to put into the standby state instantaneously due to power off input, when the
power is standby.
Immediately, state is a complete standby.
Vol (+/-) or Cursor ( / ) Change or execution of the set value.
Public Mode setting screen.
CH (+/-) or Cursor ( / ) Movement to the selected item.
Decision (ok)
Decision (ok)
Excution (Used by the items "Execution" and "RESET".)
Public Mode
POWER ON FIXED
SHUT DOWN MODE
MAXIMUM VOLUME
VOLUME FIXED
VOLUME FIXED LEVEL
RC BUTTON
PANEL BUTTON
MENU BUTTON
AV POSITION FIXED
ON SCREEN DISPLAY
INPUT MODE START
INPUT MODE FIXED
LOUD SPEAKER
RC PATH THROUGH
232C POWON
PUBLIC MODE
RESET
EXECUTE
POWER ON FIXED
SHUT DOWN MODE
MAXIMUM VOLUME
VOLUME FIXED
VOLUME FIXED LEVEL
RC BUTTON
PANEL BUTTON
MENU BUTTON
AV POSITION FIXED
ON SCREEN DISPLAY
INPUT MODE START
INPUT MODE FIXED
LOUD SPEAKER
RC PATH THROUGH
232C POWON
PUBLIC MODE
RESET
EXECUTE
[VARIABLE]
[NORMAL]
[60]
[VARIABLE]
[20]
[RESPOND]
[RESPOND]
[RESPOND]
[RESPOND]
[RESPOND]
[VARIABLE]
[YES]
[NORMAL]
[VARIABLE]
[ON]
[OFF]
[DISABLE]
[ON]
When power button on the main unit is pressed
When power button on R/C is pressed
No Power off by power button.
No Power off by remote control.
LC-60/70LE740E/RU,741E/S,743E,60LE840E/RU,841E/S,843E,80LE645E/RU,646E/S,648E
5 – 10
3) Volume maximum level [MAXIMUM VOLUME]
4) Volume fixed [VOLUME FIXED]
5) Volume fixed level [VOLUME FIXED LEVEL]
6) Remote control operation [RC BUTTON]
7) Main Unit Operation [PANEL BUTTON]
Remarks
In selecting “QUICK”, the function does not work for the following items. (selection impossible.)
• ON TIMER, QUICK START, DIGITAL FIXED, etc.
• ON TIMER, QUICK START, DIGITAL FIXED, etc.
* These items does not exist according to the model.
Option
0~60 (loop disabled)
Default 60
Function
Function
The volume cannot be increased more than the adjusted value (the main unit’s speaker only).
Remarks
• When setting to 59 or less, only the figure is displayed in the normal mode; the volume bar is not displayed.
• The volume of the headphones is limited.
• The setting is impossible when VOLUME FIXED is set to FIXED.
• The volume of the headphones is limited.
• The setting is impossible when VOLUME FIXED is set to FIXED.
Option
“VARIABLE”, “FIXED”, “ACCTRL” or “AC/RCCTRL” (loop enabled)
Default “VARIABLE”
Function • VARIABLE
Function • VARIABLE
• FIXED
• AC CTRL
• AC CTRL
• AC/RC CTRL
: The volume is not fixed.
: The volume is fixed to the value adjusted in the volume fixed level.
: The unit starts at the volume specified in the volume fixed level, when power is turned on in the
case of the AC-ON only.
: The unit starts at the volume specified in the volume fixed level, when power is turned on in
any case.
(AC
: The volume is fixed to the value adjusted in the volume fixed level.
: The unit starts at the volume specified in the volume fixed level, when power is turned on in the
case of the AC-ON only.
: The unit starts at the volume specified in the volume fixed level, when power is turned on in
any case.
(AC
→ON, remote control→ON, main utit's key→ON)
Exception
• In the adjustment process, the volume can be set to any level regardless of this setting.
Disabled key when
setting to FIXED
setting to FIXED
• VOLUME UP/DOWN [both remote control and main unit]
• MUTE
• MUTE
* Main units's key is enabled for operating menu.
Remarks
• [MAXIMUM VOLUME] has priority to [VOLUME FIXED]
* When setting to FIXED, Maximum volume is fixed.
• The volume of the headphones is fixed.
• When setting to “FIXED”, the volume is not displayed in operating Disabled key.
• In menu operation, the main unit’s keys (Vol (+/-)) are enabled.
• Volume level graphic be omitted to volume level number.
• In setting to FIXED, ONVOL of On TIMER is not selected (Eliminate Item)
• In setting to AC/RC CTRL, ONVOL of On TIMER i is not selected (Eliminate Item)
• When setting to “FIXED”, the volume is not displayed in operating Disabled key.
• In menu operation, the main unit’s keys (Vol (+/-)) are enabled.
• Volume level graphic be omitted to volume level number.
• In setting to FIXED, ONVOL of On TIMER is not selected (Eliminate Item)
• In setting to AC/RC CTRL, ONVOL of On TIMER i is not selected (Eliminate Item)
Option
0~60 (loop disabled)
Default 20
Function
Function
The volume is fixed to the adjusted value (the main unit’s speaker only).
Exception
• In the adjustment process, the volume can be set to any level regardless of this setting.
Remarks
• When [VOLUME FIXED] is set to “VARIABLE”, the setting cannot be changed.
• VOLUME can be abbreviated to VOL.
• VOLUME can be abbreviated to VOL.
Option
“RESPOND”, “NORESPOND” or “LIMITED” (loop enabled)
Default “RESPOND”
Function
Function
The operation of the remote control’s keys is set.
RESPOND
NO RESPOND
RESPOND
NO RESPOND
LIMITED
: The remote control’s keys in the normal state are enabled.
: The remote control’s keys in the normal state are disabled.
The POWER key (RECEPTION/STANDBY key) is also disabled.
: Only a part of keys (CHANNEL, etc.) is enabled and other keys are disabled.
: The remote control’s keys in the normal state are disabled.
The POWER key (RECEPTION/STANDBY key) is also disabled.
: Only a part of keys (CHANNEL, etc.) is enabled and other keys are disabled.
Exception
• All the keys are enabled regardless of this setting while entering the adjustment process mode, inspection mode or
Public Mode setting screen.
Remarks
The enable keys when setting to “LIMITED” are depended on Model.
Option
“RESPOND” or “NO RESPOND” (loop enabled)
Default “RESPOND”
Function • RESPOND
Function • RESPOND
• NO RESPOND
: The main unit’s keys are enabled.
: The main unit’s keys are disabled excluding the POWER key (RECEPTION/STANDBY key).
: The main unit’s keys are disabled excluding the POWER key (RECEPTION/STANDBY key).
LC-60/70LE740E/RU,741E/S,743E,60LE840E/RU,841E/S,843E,80LE645E/RU,646E/S,648E
5 – 11
8) Menu operation [MENU BUTTON]
9) AV position fixed [AV POSITION FIXED]
10) OSD display [ON SCREEN DISPLAY]
Exception
• The start operation in the adjustment process mode, inspection mode are enabled regardless of this setting.
• All the keys are enabled regardless of this setting while entering the adjustment process mode, inspection mode or
• All the keys are enabled regardless of this setting while entering the adjustment process mode, inspection mode or
Public Mode setting screen.
• For the models with the MENU key on the main unit, menu operation is possible regardless of the setting during the
initial setting when the power is turned on for the first time.
Option
“RESPOND” or “NO RESPOND” (loop enabled)
Default “RESPOND”
Function
Function
The MENU key on the main unit and remote control is decided whether it is enabled or disabled.
Exception
• RESPOND
• NO RESPOND
• NO RESPOND
: The manu key is enabled.
: The manu key is disabled.
: All the keys are enabled regardless of this setting while entering the process mode, inspection
mode or Public Mode setting screen.
: The manu key is disabled.
: All the keys are enabled regardless of this setting while entering the process mode, inspection
mode or Public Mode setting screen.
Disabled key excluding
Menu key when setting
to not default
Menu key when setting
to not default
All the direct transition keys to menu display. (AUTO PRESET, MANUAL MEMORY and others)
* These keys does not exist according to the model.
* These keys does not exist according to the model.
Remarks
When setting to “NO RESPOND”
• For the models with the MENU key on the main unit, menu operation is possible regardless of the setting while the
• For the models with the MENU key on the main unit, menu operation is possible regardless of the setting while the
initial setting when the power is turned on for the first time.
Option
“VARIABLE” or “FIXED” (loop enabled)
Default “VARIABLE”
Function • VARIABLE
Function • VARIABLE
• FIXED
: AV position is not fixed.
: AV position is fixed.
: The image/sound adjustment items in the menu are fixed in the selected state.
: When receiving “AV POSITION” of the remote control, only the actual state is displayed, and
setting is not changed.
: AV position is fixed.
: The image/sound adjustment items in the menu are fixed in the selected state.
: When receiving “AV POSITION” of the remote control, only the actual state is displayed, and
setting is not changed.
Remarks
• When receiving the sound select direct keys (AV POSITION key, OPC, DOLBY key, etc.), only the actual state is
displayed; no setting is changed.
* These keys does not exist according to the model.
* These keys does not exist according to the model.
• The settings for the Public mode are retained after the personal data is initialized, each item for the AV position and
image/sound adjustment are not initialized.
Option
“YES”, “NO” or “LIMITED” (loop enabled)
“LIMITED” is looped only in case of need (destination).
“LIMITED” is looped only in case of need (destination).
Default “YES”
Function • YES
Function • YES
• NO
• LIMITED
: OSD is displayed.
: The following OSD is not displayed.
Registration, setting, adjustment menu, channel call, volume bar, and input select.
: Only a part of OSD (CH call: “New Information” etc...) is not displayed.
: The following OSD is not displayed.
Registration, setting, adjustment menu, channel call, volume bar, and input select.
: Only a part of OSD (CH call: “New Information” etc...) is not displayed.
Key which may be
enabled
(Example of the confus-
ing key)
enabled
(Example of the confus-
ing key)
• It is OK in the case that simple input select occur or the original state returns soon automatically.
Disabled key when
setting to not default
setting to not default
• When setting to “NO”, the keys which is related to visibility of the screen and sound cannot be used.
STILL IMAGE, SCREEN DISPLAY, OFF TIMER, AV POSITION, BRIGHTNESS SENSOR, SCREEN SIZE SELECT,
AUTO PRESET, MANUAL MEMORY, IMAGE SELECT, SOUND SELECT, LANGUAGE, Closed caution
* Disabled keys dependeds on the models.
AUTO PRESET, MANUAL MEMORY, IMAGE SELECT, SOUND SELECT, LANGUAGE, Closed caution
* Disabled keys dependeds on the models.
Remarks
• When setting to “NO”,
ON TIMER (Watching reservation) is cleared.
OFF TIMER “SLEEP” is cleared.
* These items does not exist according to the model.
OFF TIMER “SLEEP” is cleared.
* These items does not exist according to the model.
• When setting to “NO”,
These Displays (Version-up, Public mode setting screen, Pass Word input screen of Public
Mode, the adjustment process mode, K mark of inspection mode) are enabled regardless of
this setting.
Mode, the adjustment process mode, K mark of inspection mode) are enabled regardless of
this setting.
LC-60/70LE740E/RU,741E/S,743E,60LE840E/RU,841E/S,843E,80LE645E/RU,646E/S,648E
5 – 12
11) Start mode [INPUT MODE START]
Example of option: “NORMAL”, “TVD (002TV)”, “INPUT1”, “INPUT2”, “INPUT3”, “HDMI1”, “HDMI2”, “HDMI3”, “HDMI4”.
12) Input fixed [INPUT MODE FIXED]
13) Speaker ON/OFF selection [LOUD SPEAKER]
14) Remote control path through [RC PATH THROUGH]
15) 232C power ON control [232C POWON]
Option
“NORMAL” or “Input source 1 (input selection or channel)” ... (loop enabled)
Default “NORMAL”
Function
Function
Which kinds of input source or channel is decided when the power turning on.
NORMAL
NORMAL
: The content of the last memory is followed.
Remarks
• When setting to not Normal, ON TIMER (Watching reservation) has priority.
• When setting to “NORMAL”, [INPUT MODE FIXED] is set to “VARIABLE” and [INPUT MODE FIXED] is prohibited to
• When setting to “NORMAL”, [INPUT MODE FIXED] is set to “VARIABLE” and [INPUT MODE FIXED] is prohibited to
select. (selection impossible.)
Option
“VARIABLE”, “FIXED”, “ACCTRL” or “AC/RCCTRL” (loop enabled)
Default VARIABLE
Function
Function
VARIABLE
FIXED
FIXED
AC CTRL
AC/RC CTRL
: If [INPUT MODE START] is set to Normal, input mode is not fixed.
: When “INPUT MODESTART” is active, it is impossible to switch to another channel or input
source.
: When “INPUT MODESTART” is active the unit starts at the input mode which is selected when
power is turned on in the case of the AC-ON only.
: When “INPUT MODESTART” is active the unit starts at the input mode which is selected
when power is turned on in any case.
(AC
: When “INPUT MODESTART” is active, it is impossible to switch to another channel or input
source.
: When “INPUT MODESTART” is active the unit starts at the input mode which is selected when
power is turned on in the case of the AC-ON only.
: When “INPUT MODESTART” is active the unit starts at the input mode which is selected
when power is turned on in any case.
(AC
→ON, remote control→ON, main utit's key→ON)
Disabled key when
setting to “FIXED”
setting to “FIXED”
CHANNEL (+/-), DIRECT CHANNEL buttons, FLASHBACK, INPUT SELECT, TV/VIDEO, AUTO PRESET,
MANUAL MEMORY, i.LINK, DIRECTINPUTSELECT, ATV, DTV, EPG, RADIO etc...
MANUAL MEMORY, i.LINK, DIRECTINPUTSELECT, ATV, DTV, EPG, RADIO etc...
Remarks
• If [INPUT MODE START] is Normal, this function cannot be set.
Set to “VARIABLE” automatically.
• When setting to “FIXED”,
The item related to the channel setting and input selection in Menu are not displayed.
ON TIMER (Watching reservation) is not active.
* These items does not exist according to the model.
ON TIMER (Watching reservation) is not active.
* These items does not exist according to the model.
Option
“ON” or “OFF” (loop enabled)
Default ON
Function
Function
ON
OFF
OFF
: The sound from the speakers is output.
: The sound from the speakers is not output even if the headphones are not used.
: The sound from the speakers is not output even if the headphones are not used.
Remarks
• When the VOL (+/-) key is pressed, the mute icon is displayed for 4 seconds.
• For the MUTE key and sound-related keys, caution is displayed.
• For the headphones, normal operation is possible.
• For the MUTE key and sound-related keys, caution is displayed.
• For the headphones, normal operation is possible.
Option
“OFF”, “ON: TVRCE” or “ON: TVRCD” (loop enabled)
Default OFF
Function
Function
The item decide whether the signal received by the remote control’s light-receiving section is output to the blankpin (9pin)
of RS232C.
OFF
ON: TVRCE
ON: TVRCD
of RS232C.
OFF
ON: TVRCE
ON: TVRCD
: This function is not active.
: This function is active, and remote control is active, too.
: This function is active, but remote control is not active.
: This function is active, and remote control is active, too.
: This function is active, but remote control is not active.
Exception
• In the case of “ON: TV RCD”, the start operation in the adjustment process mode, inspection mod are enabled
regardless of this setting.
• In the case of “ON: TV RCD”, all the keys are enabled regardless of this setting while entering the adjustment process
mode, inspection mode or Public mode setting screen.
Remarks
* Remote control path through does not exist according to the model.
Option
“ENABLE” or “DISABLE” (loop enabled)
Default DISABLE
Function
Function
The item decide whether Power ON by the 232C command is enabled/disabled in the standby state.
The same function as 232C command “RSPW”.
ENABLE
DISABLE
The same function as 232C command “RSPW”.
ENABLE
DISABLE
: POWR0001 is always enabled.
: Start-up may be impossible at POWR0001.
(If the 232C command reception module is set to OFF, the command is invalid.)
: Start-up may be impossible at POWR0001.
(If the 232C command reception module is set to OFF, the command is invalid.)
Click on the first or last page to see other LC-80LE646E (serv.man4) service manuals if exist.