DOWNLOAD Sharp LC-80LE646E (serv.man4) Service Manual ↓ Size: 2.23 MB | Pages: 64 in PDF or view online for FREE

Model
LC-80LE646E (serv.man4)
Pages
64
Size
2.23 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD / Adjustments
File
lc-80le646e-sm4.pdf
Date

Sharp LC-80LE646E (serv.man4) Service Manual ▷ View online

LC-60/70LE740E/RU,741E/S,743E,60LE840E/RU,841E/S,843E,80LE645E/RU,646E/S,648E
5 – 5
14/21
1
TCON Version EXT.1
xxxxx
2
TCON Version EXT.2
3
TCON Version EXT.3
4
TCON Version EXT.4
15/21
1
3DHDMI FPGA Version
xxxxx
2
2D
→3D FPGA Version
xxxxx
3
3D LED BRIGHTNESS
xxxxx
4
3D IR EMITTER CONTROL
xxxxx
16/21
[FR REGI]
1
CROSSTALK ADJ MODE
Enter
2
CROSSTALK TH1
3
CROSSTALK TH2
4
CROSSTALK TH3
5
CROSSTALK TH4
6
CROSSTALK GAIN1
7
CROSSTALK GAIN2
8
CROSSTALK GAIN3
17/21
1
WIFI SSID 2.4GHz
xxxxx
2
WIFI SSID 5  GHz
xxxxx
3
WIFI RSSI 2.4GHz
xxxxx
4
WIFI RSSI 5  GHz
xxxxx
5
WIFI TIME 5 GHz
xxxxx
6
WIFI RSSI TEST
xxxxx
7
WIFI RSSI RESULT
xxxxx
18/21
1
READ/WRITE
READ
Read/Write
2
SLAVE/ADDRESS
SLAVE0
Slave address
3
REGISTER ADDRESS
0x 0
0x 0
Register address
4
WRITE  DATA
0x  0
0x 0
Writing data
5
READ DATA
0x 0
0x 0
Reading data
19/21
1
RF AGC BG
6
RF-AGC BG adjustment execution
2
RF AGC DK
5
RF-AGC DKG adjustment execution
3
RF AGC I
6
RF-AGC I adjustment execution
4
RF AGC L/L'
4
RF-AGC L/L' adjustment execution
20/21
[ETC]
1
ERROR STANDBY CAUSE1
NO RECORD
ERROR STANDBY CAUSE
2
ERROR STANDBY CAUSE2
NO RECORD
3
ERROR STANDBY CAUSE3
NO RECORD
4
ERROR STANDBY CAUSE4
NO RECORD
5
ERROR STANDBY CAUSE5
NO RECORD
6
STANDBY CAUSE RESET
OFF
Reset stand by cause.
21/21
[ETC]
1
EEP SAVE
OFF
Writing setting values to EEPROM.
2
EEP RECOVER
OFF
Reading setting values from EEPROM.
3
MONITOR ERROR CAUSE RESET
OFF
Reset of monitor error cause
4
MODEL NAME
LE740E
MODEL NAME
5
PANEL SIZE
70
Panel size setting.
6
VERUP FLAG ENABLE
Enter
Verup Flag
7
PANEL LIMIT
ON
PANEL LIMIT
8
PANEL RANGE LIMIT
xxx
PANEL RANGE LIMIT
9
SHORT CHECK MODE
Enter
Check LED Back light
10
SHORT CHECK CURRENT
60
11
CURRENT SW
LOW
12
PRODUCT EEP ADR
0x 0
Don't touch when serving (for producer of factory)
13
PRODUCT EEP DATA
0x 0
Don't touch when serving (for producer of factory)
14
PRODUCT FACTORY
1
Don't touch when serving (for producer of factory)
15
TEST NETWORK UPDATE
No
Page
Line
Item
Description
Remarks (adjustment detail, etc.)
LC-60/70LE740E/RU,741E/S,743E,60LE840E/RU,841E/S,843E,80LE645E/RU,646E/S,648E
5 – 6
6. Special features
1. NORMAL STANDBY CAUSE (Page 1/21)
Display of a cause (code) of the last standby.
The cause of the last standby is recorded in EEPROM whenever it is possible.
Checking this code will be useful in finding a problem when you repair the troubled set.
2. EEP SAVE (Page 21/21)
Storage of EEP adjustment value.
3. EEP RECOVER (Page 21/21)
Retrieval of EEP adjustment value from storage area.
4. MONITOR ERR CAUSE (Page 1/21)
Display of a cause (code) of Error from Monitor microprocessor.
The cause of Error is recorded in EEPROM whenever it is possible.
Checking this code will be useful in finding a problem when you repair the troubled set.
1) This displays Error code and time when the error occurred.
The latest error is displayed on “1)”.
The error that happens ahead of “1)” is displayed on “2)”. 
2) The character depends on the way how to acquire Time Information.
Example)   In this example, it is shown that the error occurred 3 times.
T:
Time is acquired from digital broadcasting
This doesn’t contain “Time offset” which is considered a time difference and Daylight-Saving Time, etc. ...
U: Time is acquired from analog broadcasting (teletext)
B:
Accumulation time of Backlight 
In the case that Time information cannot be acquired, “B” is displayed.
1) 16 T07/01/01 12:03
Error code: 16 (lamp error) 
Time: 07/01/01 12:03
* It is latest Error.
* Time is acquired from digital broadcasting.
* Time is UTC which doesn't have Time offset.
2) 16 U01/01/01 04:07
Error code: 16 (lamp error)
Time: 07/01/01 04:07
* It is Error that happens ahead of “1)”.
* Time is acquired from analogue broadcasting.
3) 16 B00000004:11
Error code: 16 (lamp error) 
Accumulation time: It is displayed that 4:11 have passed after Backlight driving. 
* It is Error that happens ahead of “2)”.
4) 00 0000000000000
No error (“00” shows that the error is not occurred.)
LC-60/70LE740E/RU,741E/S,743E,60LE840E/RU,841E/S,843E,80LE645E/RU,646E/S,648E
5 – 7
7. Lamp Error detection
1. Function
This LCD color TV set incorporates a Lamp error detection feature that automatically turns off the power for safety under abnormal lamp or lamp
circuit conditions. If by any chance anything is wrong with the lamp or lamp circuit or if the lamp error detection feature is activated for some rea-
son, the following will result.
1) The power is interrupted in about 500ms after it is turned on.
(A central icon on the front of the TV flash on and off.: ON for 400ms and OFF for 1600ms.)
2) If the above phenomenon 1) occurs 5 times, it becomes impossible to turn on the power.
(A central icon keep flashing on/off.)
2.  Measures
1) Set the lamp error detection to OFF
Enter the adjustment process mode, referring to “2. Entering and exiting the adjustment process mode”.
The adjustment process mode can ignore “5 times count”, so If the above phenomenon 1) occurs 1~4 times, the lamp will go out.
If Lamp Error detection pin [4pin of PD: P9602/19pin of IC2001] is “High” by a trouble with the lamp and lamp circuit, it can boot-up by the
adjustment process mode.
Please execute “Lamp Error detection off-mode”.
    Unplug the AC power cord of running TV set to force off the power.
    While holding down the “VOL (-)” and “CH (
)” keys on the set at once, plug in the AC power cord to turn on the power.
    After a central icon flash off, separate the fingers from key on the set.
Then, you can check the operation to see if the lamp and lamp circuit are in trouble.
If you fail boot-up, retry the procedure.
2) Resetting the lamp error count
After the lamp and lamp circuit are improved from a trouble, reset the lamp error count. 
(Because the power cannot be turned on, if a lamp error is detected 5 consecutive times.)
a) Enter the adjustment process mode, referring to “2. Entering and exiting the adjustment process mode”.
b) Using the cursor ( /
) key, move to the cursor to [LAMP ERROR RESET], Line 8 on adjustment process mode service page 2/21.
c) With the cursor ( / ) keys, select the [LAMP ERROR RESET] value.
Finally press the cursor (OK)., the count is reset.
Check LAMP ERROR Count on adjustment process mode Page 2/21.
Table of contents of adjustment process mode Page 2/21
INDUSTRY INIT
Enter
INDUSTRY INIT (-Publicl)
OFF
PUBLIC MODE
OFF
Center Acutime
RESET
OFF
Backlight Acutime
RESET
OFF
LAMP ERROR RESET
OFF
Resetting to "0"
ADJ PARAM SET
Enter
VIC XPOS
0
VIC YPOS
0
VIC SIGNAL TYPE
MAIN
VIC READ
OFF
LC-60/70LE740E/RU,741E/S,743E,60LE840E/RU,841E/S,843E,80LE645E/RU,646E/S,648E
5 – 8
8. Public Mode
1. Starting the Public Mode
1)  Method of needing password
a)  While holding down the  “INPUT" and   "Volume UP"  keys on the set at once, plug in the AC power cord to turn on the power.
b) Display the Pass Word input screen.
After a while, value of Enter password appears on the screen.
Operation procedure
• The initial input position is the digit at the left end.
• For the numeric keys “0”  to “9”  of R/C, key input is accepted.
Input of the other keys is prohibited.
• Change “—” to “ ” by inputting the numeric key at the input position, and shift the input position rightward one digit.
• When three digits are completely input, the Pass Word is judged.
c) Check the Pass Word by inputting three digits.
If the Pass Word “0”  “2”  “7”, it shifts to the PUBLIC Mode setting screen.
In another case, the screen is erased, and it operates in the ordinary mode.
2. Exiting the Public Mode Setting screen
• There are two following ways to exit the Public Mode setting screen.
1) Turn off the power.
2) Select “Execution” in the PUBLIC_Mode to execute it.
Activate the restart under the set content.
Here, the START input SOURCE setting is excluded since this item is referred to only when the power is turned on.
3. Set value of the Public Mode
• When the shipment setting is done, a set each value in Public Mode is initialized.
(PUBLIC MODE in the process mode Setting of a flag is also initialized)
• Separately, the shipment beginnings when all except for each set value in Public Mode is initialized are provided for a process mode.
(INDUSTRY INIT (-Public))
• Only when turning on the PUBLIC MODE item, each setting is effective.
• After it decides it with EXECUTE, it AC OFF/ON it to reflect a set value.
Enter password
Enter password
Enter password
Page of 64
Display

Click on the first or last page to see other LC-80LE646E (serv.man4) service manuals if exist.