LC-60LE635E/636E/638E (1st Edition)
4 – 5
5. Removing of R/C, Operation Unit, ICON Unit, 3D IR Emitter Unit, Touch Sensor Unit.
1. Remove the 1 lock screw   and detach the ICON Unit  .
2. Detach the R/C, Operation Unit  .
3. Detach the 3D IR Emitter Unit  .
4. Detach the Touch Sensor Unit  .
NOTE: The Touch Sensor unit   reuse will be impossible, once it is stuck on front cabinet and exfoliates.
Front Cabinet Ass'y
[TK] [RA]
Touch Sensor Unit
2
[IR]
[RA]
[CI]
3
ICON
Unit
5
6
3D IR Emitter
Unit
4 R/C,
Operation
Unit
LC-60LE635E/636E/638E (1st Edition)
4 – 6
[2] The location putting on the heat measure sheet
1. MAIN PWB Unit
The object to cool.
(The sheet is put on the back of the
board.)
The guide line is impressed on the backlight
chassis
PSPAZC702WJKZ
Main PWB Unit
(DUNTKF733WE**)
LC-60LE635E/636E/638E (1st Edition)
4 – 7
2. LCD Control Unit
LCD control unit
(RUNTK4910TP**)
The IC to cool
Please put [PSPAZC0062WJKZ] on the IC
LC-60LE635E/636E/638E (1st Edition)
4 – 8
[3] Precautions for assembly
1. Attaching the touch sensor
1. After removing the release paper, attach the touch sensor keeping out dust and dirt.
2. Press the 3 circular silk positions on the PWB to fix the touch sensor. There is no problem if the pressing positions are slightly misaligned. How-
ever, do not press the connectors directly since they are very easy to break.
2. Points to be checked and precautions when servicing the unit
Mount the main PWB Ass’y on the backlight chassis and check that the EMI-prevention parts are not peeled and twisted from the access holes. (The
EMI-prevention parts, conductive nonwoven fabric gaskets, must be seen from the access holes.)
[Countermeasure]
Attach the conductive nonwoven fabric gaskets on the shielded case on the main PWB.
PSPAZC690WJZZ
PSPAZC691WJZZ x 2 pcs
Attach the conductive nonwoven fabric gasket on the RF terminal angle.
(PSPAZC691WJZZ)