LC-32/40/46LE700E/RU/S,LU700E/S,LX700E/RU,LC-52LE700E/RU/S
5 – 9
6. Setting items (* Item names and selective items are expressed in English.)
1) Power ON fixed [POWER ON FIXED]
If the power button is pressed in the ordinary mode in setting to “FIXED_ALL”, the caution is displayed for 5 seconds.
* The OSD display is an example.
  If another ODS is previously displayed, the status is reset (MENU or similar).
2) Instantaneous current shutdown setting in turning off the power [SHUT DOWN MODE]
3) Volume maximum level [MAXIMUM VOLUME]
Option 
“VARIABLE”,”FIXED_ALL”, “FIXED_BODYKEY” or “RCRESPOND” (loop enabled)
Default “VARIABLE”
Function • VARIABLE 
• FIXED_ALL
• FIXED_BODYKEY
• RC RESPOND
: “POWER/RECEPTION” key on TV unit or remote control is enabled
: “POWER/RECEPTION” key on TV unit or remote control is disabled.
: only the “MAIN POWER” key on TV unit is disabled
 (the remote control is enabled).
: the main unit’s POWER switch toggles between ON and Standby
 (the same operation by the remote control).
Key disabled when set 
other than default
• OFF TIMER (SLEEP)
 
• In selecting to “FIXED_ALL”, function related standby factors (see below) doesn't work. and not selecting
OFF TIMER (Sleep)
No operation OFF
No signal OFF (including the power management)
Option 
“NORMAL” or “QUICK”
Default NORMAL
Function 
• This function decides whether scanning digital tuner is enabled or disabled when the power is standby.
NORMAL 
QUICK
: Scanning digital tuner is enabled when the power is standby.
: Scanning digital tuner is disable 
  It is possible to put into the standby state instantaneously due to power off input, when the power is standby.
  Immediately, state is a complete standby. 
Remarks
In selecting “QUICK”, the function does not work for the following items 
(selection impossible.)
• ON TIMER, QUICK START, DIGITAL FIXED, etc.
Option 0~60(loopdisabled)
Default 60
Function 
The volume cannot be increased more than the adjusted value (the main unit’s speaker only).
Remarks
• In setting to 59 or less, only the figure is displayed in the normal mode; the volume bar is not displayed.
• The volume of the headphones or monitor output is limited.
• The setting is impossible when VOLUME FIXED is set other than VARIABLE.
When power button on the main unit is pressed
When power buttonon R/C is pressed
No Power off by power button.
No Power off by remote control.
LC-32/40/46LE700E/RU/S,LU700E/S,LX700E/RU,LC-52LE700E/RU/S
5 – 10
4) Volume fixed [VOLUME FIXED]
5) Volume fixed level [VOLUME FIXED LEVEL]
6) Remote control operation [RC BUTTON]
7) Main Unit Operation [PANEL BUTTON]
Option 
“VARIABLE”, “FIXED”, “ACCTRL” or “AC/RCCTRL” (loop enabled)
Default “VARIABLE”
Function • VARIABLE 
• FIXED
• AC CTRL
• AC/RC CTRL
: The volume is not fixed.
: The volume is fixed to the value adjusted in the volume fixed level.
: The unit starts at the volume specified in the volume fixed level, 
  when power is turned on in the case of the AC-ON only.
: The unit starts at the volume specified in the volume fixed level, 
  when power is turned on in any case.)
  (AC->ON, remote control->ON, main utit's key->ON)
Exception 
• In the adjustment process, the volume can be set to any level regardless of this setting.
Key disabled in setting
to FIXED
• VOLUME UP/DOWN (VOL+/-) [both remote control and main unit]
• MUTE (MUTE) * The main unit’s keys for the menu operation are enabled.
Remarks
• [MAXIMUM VOLUME] has priority to “VOLUME FIXED”
* In setting to FIXED, Maximum volume is fixed.
• The volume of the headphones or monitor output is fixed.
• in setting to “FIXED”, the volume is not displayed in operating Disabled key 
Option 0~60(loop 
disabled)
Default 20
Function 
The volume is fixed to the adjusted value (the main unit’s speaker only). 
Exception 
• In the adjustment process, the volume can be set to any level regardless of this setting.
Remarks
• When “VARIABLE” is selected in VOLUME FIXED, the setting cannot be selected and changed.
• VOLUME can be abbreviated to VOL.
Option 
“RESPOND”, “NORESPOND” or “LIMITED” (loop enabled)
Default “RESPOND”
Function
The operation of the remote control’s keys is set.
 • RESPOND 
• NO RESPOND 
• LIMITED 
: the remote control’s keys in the normal state are enabled.
: the remote control’s keys in the normal state are disabled.
  The POWER key (RECEPTION/STANDBY key) is also disabled. 
: only a part of keys (CHANNEL, etc.) is enabled and other keys are disabled.
(POWER, VOLUME (
/
), CHANNEL (
/
), LIGHT CONTROL (BRIGHT-
NESS SENSOR) BROADCAST SELECT)
Exception 
• In the adjustment process mode, inspection mode or hotel mode keys are enabled regardless of this setting.
• All the keys are enabled regardless of this setting while entering the adjustment process mode, inspection mode or 
hotel mode.
Remarks
The enable keys in setting to “LIMITED” are depended on keys of controller for hotel.
It is different accordinf to region.
Option 
“RESPOND” or “NORESPOND” (loop enabled)
Default “RESPOND”
Function
The operation of the remote control’s keys is set.
 • RESPOND 
• NO RESPOND 
: The main unit’s keys are enabled.
: The main unit’s keys are disabled excluding the POWER key
  (RECEPTION/STANDBY key). 
Exception 
• The start operation in the adjustment process mode, inspection mode or hotel mode are enabled regardless of this 
setting.
• All the keys are enabled regardless of this setting while entering the adjustment process mode, inspection mode or 
hotel mode.
• For the main unit’s MENU key, menu operation is possible regardless of the setting during the initial setting when 
the power is turned on for the first time.
LC-32/40/46LE700E/RU/S,LU700E/S,LX700E/RU,LC-52LE700E/RU/S
5 – 11
8) Menu operation [MENU BUTTON]
9) AV position fixed [AV POSITION FIXED]
10)OSD display [ON SCREEN DISPLAY]
11)Start mode [INPUT MODE START]
Example of option: “NORMAL”
“TVD(002TV)”, “INPUT1”, “INPUT2”, “INPUT3”, “PC”, “HDMI1”, “HDMI2”, “HDMI3”, “INPUT8”
Option 
“RESPOND” or “NO RESPOND” (loop enabled)
Default “RESPOND”
Function
The MENU key on the main unit and remote control is decided whether it is enabled or disabled.
Exception
• RESPOND 
• NO RESPOND 
: The menu key is enabled.
: The menu key is disabled.
: The start operation in the adjustment process mode, inspection mode or hotel mode. 
  is enabled regardless of this setting.
: All the keys are enabled regardless of this setting while entering the process mode,
  inspection mode or hotel mode.
Disabled key excluding 
Menu key
in setting not default
All the direct transition keys to menu display (AUTO PRESET, MANUAL MEMORY and others)
Remarks
In setting to “NO RESPOND”.
• For the models with the MENU key on the main unit, menu operation is possible regardless of the setting during the 
initial setting when the power is turned on for the first time.
Option 
“VARIABLE” or “FIXED” (loop enabled)
Default “VARIABLE”
Function
• VARIABLE 
• FIXED 
: AV position is not fixed.
: AV position is fixed.
: the image adjustment and sound adjustment items in the menu 
  are fixed in the selected state.
: In receiving “AV POSITION” of the remote control, only the actual state is displayed, 
  and no setting is changed.
Exception 
• In receiving the sound select direct keys (AV POSITION key, OPC, DOLBY key, etc.),
only the actual state is displayed; no setting is changed.
• Since the settings for the hotel mode are retained after the personal data is initialized, 
each item for the AV position and image adjustment and each value for the sound adjustment are not initialized.
Option 
“YES”, “NO” or “LIMITED” (loop enabled)
“LIMITED” is looped only in case of need (destination).
Default YES
Function
• YES
• NO
• LIMITED
: OSD is displayed 
: the following OSD is not displayed.
  Registration, setting, adjustment menu, channel call, volume bar, and input select
: only a part of OSD (CH call: "New Information") is not displayed.
Key which may be
enabled 
(Example of the confusing 
key)
• OK if simple input select occurs or the original state returns soon if left. 
Disabled key 
in setting not default
• In setting to “NO”, the keys which is related to visibility of the screen and sound cannot be used.
STILL IMAGE, SCREEN DISPLAY, OFF TIMER, AV POSITION, BRIGHTNESS SENSOR, 
SCREEN SIZE SELECT, AUTO PRESET, MANUAL MEMORY, IMAGE SELECT, SOUND SELECT, 
LANGUAGE, Closed caution
Remarks
In setting to “NO”,
ON TIMER (Watching reservation) is cleared.
OFF TIMER “SLEEP” is cleared.
Option 
“NORMAL” or “Input source 1 (input selection or channel)” 
⋅ ⋅ ⋅ (loop enabled)
Default “NORMAL”
Function
which kinds of input source or channel is decided when the power turning on.
NORMAL: the content of the last memory is followed.
Remarks
• In setting to not Normal,
ON TIMER (Watching reservation) has priority.
• In setting to “NORMAL”, [INPUT MODE FIXED] is set to “VARIABLE”. 
and [INPUT MODE FIXED] is prohibited to select.(selection impossible.)
LC-32/40/46LE700E/RU/S,LU700E/S,LX700E/RU,LC-52LE700E/RU/S
5 – 12
12)Input fixed [INPUT MODE FIXED]
13)Speaker ON/OFF selection [LOUD SPEAKER]
14)Remote control path through [RC PATH THROUGH]
15)232C power ON control [232C POWON]
16)Hotel mode setting [HOTELMODE]
Option 
“VARIABLE” “FIXED”, “ACCTRL” or “AC/RCCTRL” (loop enabled)
Default VARIABLE
Function
• VARIABLE
• FIXED
• AC CTRL
• AC/RC CTRL
: input mode is not fixed. 
: when “INPUT MODESTART” is active, it is impossible to switch to another channel or input
: when “INPUT MODESTART” is active the unit starts at the input mode which is selected
  when power is turned on in the case of the AC-ON only.
: when “INPUT MODESTART” is active
  the unit starts at the input mode which is selected when power is turned on in any case
  (AC->ON, remote control->ON, main utit's key->ON)
Disabled key in setting
to “FIXED” 
CHANNEL (
/
), DIRECT CHANNEL buttons, FLASHBACK, INPUT SELECT,   
TV/VIDEO, AUTO PRESET, MANUAL MEMORY,i.LINK,DIRECTINPUTSELECT,ATV,DTV,EPG,RADIO
Remarks
• If [INPUT MODE START] is Normal, this function cannot be set. Set to “VARIABLE” automatically.
• In setting to “FIXED”
The channel setting and input selection in Menu are not displayed.
ON TIMER (Watching reservation) is not active.
Option 
“ON” or “OFF” (loop enabled)
Default ON
Function
ON
OFF
: The sound from the speakers is output. 
: The sound from the speakers is not output even if the headphones are not used. 
Remarks
• When the VOLUME UP/ DOWN key is pressed, the mute icon is displayed for 4 seconds.
• For the MUTE key and sound-related keys, caution is displayed.
• For the headphones and monitor output sound, normal operation is possible.
Option 
“OFF”, “ON:TVRCE” or “ON:TVRCD” (loop enabled)
Default OFF
Function
The item decide whether the signal received by the remote control’s light-receiving section is output to the blank-
pin(9pin) of RS232C.
OFF
ON:TVRCE
ON:TVRCD
: this function is not active.
: this function is active, and remote control is active, too
: this function is active, but remote control is not active
Exception
• In the case of “ON:TV RCD”, the start operation in the adjustment process mode,
inspection mode or hotel mode are enabled regardless of this setting.
• In the case of “ON: TV RCD", all the keys are enabled regardless of this setting. 
while entering the adjustment process mode, inspection mode or hotel mode.
Remark
There is case that the model can't always output due to the structure of the hardware.
Option 
“ENABLE” or “DISABLE” (loop enabled)
Default DISABLE
Function
The item decide whether Power ON by the 232C command is enabled/disabled in the standby state.
The same function as 232C command “RSPW”.
ENABLE
DISABLE
: POWR0001 is always enabled.
: Start-up may be impossible at POWR0001.
  ( If the 232C command reception module isset to OFF, the command is invalid.)
Exception
• In the case of “ON:TV RCD”, the start operation in the adjustment process mode,
inspection mode or hotel mode are enabled regardless of this setting.
• In the case of “ON: TV RCD", all the keys are enabled regardless of this setting. 
while entering the adjustment process mode, inspection mode or hotel mode.
Remark
There is case that the model can't always output due to the structure of the hardware.
Option 
“OFF” or “ON” (loopen abled)
Default OFF
Function
The item decide whether hotel mode setting menu are enabled or disabled.
The same item as [HOTELMODE] in the adjustment process menu.
OFF
DISABLE
: Hotel mode is not active.
: ON.
Remark
Each operation of the hotel mode is impossible unless this item is set to ON.
Page of 18
Display

Click on the first or last page to see other LC-52LE700E (serv.man7) service manuals if exist.