Sharp LC-42XD1EA (serv.man3) Service Manual ▷ View online

LC-42XD1EA/RUA
3 – 9
8/13
[M GAMMA 1-3]
1
M GAMMA R 1
107
W/B adjustment, gradation 1R adjustment value
2
M GAMMA G 1
107
W/B adjustment, gradation 1G adjustment value
3
M GAMMA B 1
107
W/B adjustment, gradation 1B adjustment value
4
275
W/B adjustment, gradation 2R adjustment value
5
275
W/B adjustment, gradation 2G adjustment value
6
275
W/B adjustment, gradation 2B adjustment value
7
446
W/B adjustment, gradation 3R adjustment value
8
446
W/B adjustment, gradation 3G adjustment value
9
446
W/B adjustment, gradation 3B adjustment value
10
off/on
EEP writing of adjustment values
9/13
[M GAMMA 4-6]
1
M GAMMA R 4
660
W/B adjustment, gradation 4R adjustment value
2
M GAMMA G 4
660
W/B adjustment, gradation 4G adjustmnet value
3
M GAMMA B 4
660
W/B adjustment, gradation 4B adjustment value
4
835
W/B adjustment, gradation 5R adjustment value
5
835
W/B adjustment, gradation 5G adjustmnet value
6
835
W/B adjustment, gradation 5B adjustment value
7
960
W/B adjustment, gradation 6R adjustment value
8
960
W/B adjustment, gradation 6G adjustment value
9
960
W/B adjustment, gradation 6B adjustment value
10
off/on
EEP writing of adjustment values
10/13
[ETC]
1
EEP CLEAR
off/on
Clear of process
㵘adjustment EEP value
2
EEP CLEAR B
off/on
Clear of process adjustment value
㵘of B_mode.
3
STANDBYCAUSE RESET
off/on
Reset of STANDBY CAUSE
4
0/1
1
䋺* * * 0䋺* * *
5
OPTION
0
6
AUTO/EURO/UK
Destination setting
7
0
LAMP ERR RESET Initialization of L_ERR
8
0/1
LAMP ERR Inhibit L_ERR detection.
9
DTV CLR
off/on
Clear of DTV unit.
10
off/on
STOP of I2C DATA execution
11/13
[LCD]
1
OSC FREQ50
1279
INVERTER drive frequency setting
2
OSC FREQ60
1279
INVERTER drive frequency setting
3
PWM FREQ50
218
Frequency setting for INVERTER dimmer
4
PWM FREQ60
218
Frequency setting for INVERTER dimmer
5
VCOM ADJ
64
COMMON VIAS adjustment setting
6
QS
off/on
on/off of Quick Shoot Function
12/13
[LCD TESTPATTERN]
1
PATTERN
0
Display LCD test pattern.
13/13
Service B
1
[HDTV]
0-10
Contrast,Bright and Color Adjustment of HDTV
2
[SERVICE B2]
off/on
on/off of Auto Sw Adjustment
3
[BASE GAMMA 1]
0-1023
Base Gamma Adjustment 1
4
[BASE GAMMA 2]
0-1023
Base Gamma Adjustment 2
5
[BASE GAMMA 3]
0-1023
Base Gamma Adjustment 3
6
[BASE GAMMA 4]
0-1023
Base Gamma Adjustment 4
7
[BASE GAMMA 5]
0-1023
Base Gamma Adjustment 5
8
[BASE GAMMA 6]
0-1023
Base Gamma Adjustment 6
9
[QUICK SHOOT]
0-255
QS Sreshuhorld Level Adjustment
M GAMMA R 5
M GAMMA G 5
M GAMMA B 5
M GAMMA R 6
M GAMMA G 6
M GAMMA B 6
M GAMMA WRITE
AUTO INSTALLATION SW
COUNTRY
L ERR RESET
L ERR STOP
I2C-OFF
M GAMMA G 3
M GAMMA B 3
M GAMMA WRITE
M GAMMA R 2
M GAMMA G 2
M GAMMA B 2
M GAMMA R 3
LC-42XD1EA/RUA
3 – 10
6. Special features
* ERROR STANDBY CAUSE (Page 1/13)
The total time when the unit enters the standby due to operational error and cause of error are recorded on EEPROM as much as possible.
The values can be used to locate the fault for repair.
* EEP CLEAR (Page10/13)
Clear of process adjustment EEP value.
7. Video signal adjustment procedure * The adjustment process mode menu is listed in Section 5.
1. Signal check
Signal generator level adjustment check (Adjustment to the specified level)
• Composite signal PAL: 0.7Vp-p 
± 0.02Vp-p (Pedestal to white level)
• 15K component signal: Y level 0.7Vp-p 
± 0.02Vp-p (Pedestal to white level)
 (50 Hz)                              PB, PR level 0.7Vp-p 
± 0.02Vp-p
2. Entering the adjustment process mode
Enter the adjustment process mode according to Section 3. 
3. RF AGC adjustment 1
1
Setting
䊶 Feed the PAL Split Field colour bar signal (E-12ch) to TUNER.
㵘 Signal level: 65dB V㩷± 1dB (75
LOAD)
Split Field Colour Bar
2
Auto adjustment
Adjustment process
Bring the cursor on [
RF AGC BG ADJ] and press [OK]
performance
[PAL+TUNERMAIN] menu
[
RF AGC BG ADJ
㵘OK] appears when finished.
Adjustment Conditions
Adjustment procedure
Adjustment point
㸡100% white
[E-12CH]
[Signal]
PAL
RF signal UV
[Terminal]
TUNER
LC-42XD1EA/RUA
3 – 11
4. Tuner adjustment
8. White Balance Adjustment
Adjustment gradation values (IN) appear on page 7/13 of process adjustment, and adjustment initial values (offset value) appear on pages 8/13 and
9/13. 
For white balance adjustment, adjust the offset values on pages 8/13 and 9/13.
[Condition of the unit for inspection]
 Modulated light: MAX (+8)
[Adjustment reference device]
Minolta CA-210
[Adjustment]
Check that the values on page 7/13 of process adjustment are set as below. If not, change them accordingly.
1. Display the current adjustment status at point 6. (Page 8/13 of process adjustment)
The display for checking the adjustment status is toggled by pressing the “6” button on the remote control.
(Normal OSD display 
→ “6” → display for check (OSD disappears) → “6” →normal OSD display → . . . )
2. Read the value of the luminance meter. x=0.272, y =0.277
3. Change MGAMMA R6/MGAMMA B6 (Adjustment offset value) on page 9/13 of process adjustment so that the values of the luminance meter
approach x=0.272 and y =0.277.
(Basically, G is not changed. If adjustment fails with R and B, change G. When G is lowered, the weaker of R and B must be fixed.)
4. Display the adjustment status of the current point 5. (Each time the “5” button on the remote control is pressed, the adjustment status check dis-
play is toggled.)
(Normal OSD display 
→ “5” → Check display (OSD disappears) → “5” →Normal OSD display → . . . )
Change M GAMMA R5/M GAMMA B5 (adjustment offset value) on page 9/13 of process adjustment so that the values of the luminance meter
approach x = 0.272 and y = 0.277.
5. Repeat step 4) for points 4, 3, 2, and 1.
MGAMMA POS 1
4
MGAMMA POS 2
9
MGAMMA POS 3
14
MGAMMA POS 4
19
MGAMMA POS 5
24
MGAMMA POS 6
29
1 Setting
[Signal]
PAL
PAL split colour bar
䊶Feed the PAL Split colour bar to TUNER.
RF signal
䊶Make sure㵘the PAL colour bar pattern (E-12) has㩷the sync level of
㵘7:3 with the picture level.
[Terminal]
TUNER
㸡100% white
2
Auto adjustment
Adjustment process
Bring the cursor on [
TUNER ADJ]
and press [OK].
performance
Page3.
[
TUNER ADJ
OK] appears when finished.
Adjustment point Adjustment conditions
䈀E-12CH䈁
Adjustment procedure
LC-42XD1EA/RUA
3 – 12
[Adjustment reference standard value]
Adjustment spec 
± 0.004    Inspection spec ± 0.006 (point 1)
Adjustment spec 
± 0.002    Inspection spec ± 0.004 (Excluding the above-mentioned)
9. Initialization to factory settings
Caution: When the factory settings have been made, all user setting data, including the channel settings, are
initialized. (The adjustments done in the adjustment process mode are not initialized.) Keep this in
mind when initializing these settings.
1
Factory settings
[Factory setting with adjustment process mode]
䊶 Enter the adjustment process mode.
(See to below caution)
䊶 Move the cursor to [Factory Init] on page 2/13.
䊶 Use the R/C 㵘㵘key to select a region from
[EURO/UK/ITALY/FRANCE/RUSSIA]and press the [OK]
㵘key.
䊶 “EXECUTING” display appears .
䊶 After a while, "OK" display appears, the setting is completed.
[Factory setting with R/C key]
䊶 Enter the adjustment process mode.
䊶 Push a remote controller code of each destination. (See below )
䊶 It automatically becomes in the process adjustment menu (INIT)
and change FACTORY INIT becomes "EXECUTING" display.
䊶 After a while, "OK" display appears, the setting is completed.
destination
R/C code
42XD1K
䊶䊶䊶
䊶䊶
䊶䊶
䊶䊶
䊶䊶
䊶䊶
A8(Hex)
42XD1I
䊶䊶䊶E8(Hex)
42XD1F
䊶䊶䊶E9(Hex)
42XD1R
䊶䊶䊶EB(Hex)
42XD1E
䊶䊶䊶FE(Hex)
The following items are initialized in the factory setting.
1. User settings
2. Channel data (e.g. broadcast frequencies)
3. Maker option setting
4. Password data
After adjustments, exit the adjustment process mode.
To exit the adjustment process mode, turn off the MAIN power key.
When the power is turned off with the remoto control, unpulug the AC power cord and plug it back in.
ends by turning off the
MAIN POWER key.
Adjustment item
Adjustment conditions
Adjustment procedure
Page of 14
Display

Click on the first or last page to see other LC-42XD1EA (serv.man3) service manuals if exist.