LC-40/46/52LE820E, LC-40/46LU820E
7 – 13
[2] LED flashing specification at the time of the error
Display method
• Refer to Table 1.
• LED that can be used is only one of the central icons.
This expresses the error situation by combining blinking at low speed and blinking at high speed.
• For this model, the blinking pattern displayed first is only a low-speed blinking.
This expresses a rough content of the error.
• For this model, details are displayed by high-speed blinking by pushing remote control MENU key.
This expresses details of the error.
Details are distinguished by the blinking frequency.
• It doesn't return to the outline display again (blink at low speed) by pushing the MENU key (The toggle is not done).
Please confirm “MONITOR ERR CAUSE” of the adjustment Process mode (1/21), when the error doesn't reproduce by having returned from the
error. 
• The process of the upgrade is expressed by the brightness of point LED that smoothness changes.
• The upgrade completion is expressed by the LED brightness that changes in a staircase pattern.
LED flashing method
<Examination for a rough content of the error>
<Examination for details of the error> 
<Upgrade executing> 
<Upgrade completion> 
Central icons
By pushing remote control MENU key.
400ms
400ms
1600ms
OFF
ON
Central icons
1600ms
300ms
100ms
400ms
400ms
1600ms
OFF
ON
Central icons
500ms
500ms
OFF
ON
Central icons
1000ms
1000ms
1000ms
1000ms
OFF
ON
LC-40/46/52LE820E, LC-40/46LU820E
7 – 14
Table 1. Concrete flashing pattern
*2: It depends on the system. The power supply error suitable for the product is defined.
*3: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
*4: If the boot section is abnormal, there is no flashing (flashing disabled).
MONITOR ERR STBY table
Item
Expression for a rough content
Expression for Details
Cause
low-speed
blinking
high-speed 
blinking
low-speed
blinking
high-speed 
blinking
Lamp system failure  Flashes once 
Flashes once 
Flashes once 
Lamp error
Power PWB failure
Flashes twice 
Flashes twice 
Flashes once 
Power Error 1 AC_DET error (*2) 
(Power failure, etc.)
Flashes twice 
Power Error 2 UR+13.5V error (*2) 
Flashes 3 times 
Power Error 3 D3.3V error (*2) 
Flashes 5 times 
Panel power supply error
Main PWB failure 
Flashes 3 times 
Flashes 3 times 
Flashes once 
Initial communication error
(Communication Flashes 
twice 
Start-up confirmation communication error
failure, etc.) 
Flashes 3 times 
Regular communication error
Flashes 5 times 
Other communication error
Others 
Flashes 4 times 
Flashes 4 times 
Flashes once 
Temperature error
Flashes twice 
Sync error
Flashes 3 times 
Notification from the main microprocessor 
(*3)
Upgrade executing 
smoothness 
changes. 
Version upgrading
Upgrade completion
a staircase 
pattern. 
Version upgrade succeeded
Upgrade failed 
Flashing
(Continuous)
Version upgrade failed
ROM data failure 
Flashing
(Continuous)
Start-up after failing version upgrade (*4)
Outline: Communication/Power failure detected by the monitor microprocessor (IC2002) is stored on EEPROM, states can be confirmed in the 
adjustment process mode.
Location: Page 1/21 of the adjustment process mode: MONITOR ERR CAUSE “0” if there is no error. It is cleared to 0 on the page (2/21) of the 
adjustment process mode.
Display Error 
description
02
Start-up communication error 2 
Initial communication from the main CPU is not received.
03
Start-up communication error 3 
Only the initial communication is received.
04
Start-up communication error 4
Until panel information request reception
05
Start-up communication error 5
Until initialization completion reception
06
Start-up communication error 6
Until version notification transmission
07
Start-up communication error 7
Until start-up information notification transmission
08
Start-up communication error 8
Until start-up information response reception
09
Start-up communication error 9
Until time-out setting reception
0A
Communication error A 
REQ time-out
0B
Communication error B 
Restart time-out during the beginning of time acquisition start-up
0C
Communication error C 
Ending sequence time-out
0D
Communication error D 
Preset start-up time-out during completion
0E
Communication error E 
Download start-up time-out
0F
Communication error F 
Time acquisition time-out
11
 Communication error H
Regular communication time-out
16
Panel-related error 
Lamp failure
1A
Other error 2 
Monitor temperature failure
1D
Power supply error 1 
PS_ON (AC_DET) failure
1E
Power supply error 2 
D_POW (DET_13V) failure
1F
Power supply error 3 
D_POW (DET_D3V3) failure
21
Power supply error 5 
Panel power failure
23
Other error 3 
Error standby request from the main CPU
LC-40/46/52LE820E, LC-40/46LU820E
7 – 15
LED flashing timing chart at the time of the error
1) Low-speed blinking
2) Lamp failure details (Low-speed blinking: Flashes once + High-speed blinking)
3) Power failure details (Low-speed blinking: Flashes twice + High-speed blinking)
Error type
Expression of Central Icon LED
Note: Pins are monitor microprocessor pins (IC2002).
Lamp failure
low-speed blinking
Flashes once
H: ON
L: OFF
Refer to “Lamp failure details”.
LOW/High blinking by pressing the [MENU] key on the remote 
control.
Power failure
low-speed blinking
Flashes twice
H: ON
L: OFF
Refer to “Power failure details”.
LOW/High blinking by pressing the [MENU] key on the remote 
control.
Communication 
failure with main CPU
low-speed blinking
Flashes 3 times
H: ON
L: OFF
Refer to “Communication failure details”.
LOW/High blinking by pressing the [MENU] key on the remote 
control.
Communication line failure or main CPU communication failure.
Others
low-speed blinking
Flashes 4 times
H: ON
L: OFF
Refer to “Other failure details”.
LOW/High blinking by pressing the [MENU] key on the remote 
control.
Error type
Expression of Central Icon LED
Note: Pins are monitor microprocessor pins unless otherwise
          specified (IC2002).
Lamp failure
Flashes once
(High speed)
H: ON
L: OFF
ERR_PNL (40pin): Abnormal H.
Confirmed after 8 consecutive detections at 64ms intervals 
(detected only when the backlight is on).
NOTE: After 5 detection counts, the lamp cannot be activated 
except in the monitoring process.
To confirm the problem, “Lamp Error detection off-mode” 
is prepared.
This mode compulsorily starts the set disregarding the 
count.
Please refer to [ADJUSTMENT PROCEDURE - 7. Lamp 
Error detection]
Error type
Expression of Central Icon LED
Note: Pins are monitor microprocessor pins unless otherwise
          specified (IC2002).
PS_ON
AC_DET failure
Flashes once 
(High speed)
H: ON
L: OFF
AC_DET (72pin: Abnormal (L).
If error is detected during start-up or operation, the power is turned 
on again by interrupt handling (instantaneous blackout process-
ing).
SM_POW
Main 13V failure
Flashes twice 
(High speed)
H: ON
L: OFF
DET_13V (38pin): Abnormal (L). Main 13V is not applied.
If error is detected during start-up or operation, the power is turned 
on again by polling.
D_POW
Digital 3.3V failure
Flashes 3 times 
(High speed)
H: ON
L: OFF
DET_D3V3 (36pin): abnormal (L). Digital 3.3V is not applied.
If error is detected during start-up or operation, the power is turned 
on again by polling.
PANEL_POW
Panel 12V failure
Flashes 5 times 
(High speed)
H: ON
L: OFF
DET_PNL12V (35pin): abnormal (L).
DET_PNL12V is not applied.
Detection starts after receiving command from Panel Power ON. 
The power is turned off by polling.
100ms
400ms
1.6sec
LC-40/46/52LE820E, LC-40/46LU820E
7 – 16
4) Communication failure details (Low-speed blinking: Flashes 3 times + High-speed blinking)
5) Other failure details (Low-speed blinking: Flashes 4 times + High-speed blinking)
Error type
Expression of Central Icon LED
Note: Basically, debug print logs are analyzed or 
          communication logs are analyzed by a bus monitor.
Initial communication 
reception failure
Flashes once
(High speed)
H: ON
L: OFF
Initial communication from the main CPU is not received.
(Request for the monitor model No. is not received.)
→ Communication line failure or main CPU start-up failure
Start-up confirmation 
reception failure
Flashes twice 
(High speed)
H: ON
L: OFF
Start-up reason confirmation from the main CPU cannot be 
received.
(Startup communication until start-up reason notification command 
is not received.)
→ Main CPU start-up failure or monitor microprocessor reception
    failure
Regular communica-
tion failure
Flashes 3 times
(High speed)
H: ON
L: OFF
Regular communication that is performed at 1 second intervals in 
the normal operation is interrupted.
→ Main CPU operation failure or monitor microprocessor 
    reception failure
Other communica-
tion failure
Flashes 5 times
(High speed) 
H: ON
L: OFF
When a request (PM_REQ=H) is sent from the main microproces-
sor, the request command is not output from the main CPU, etc.
→ Main CPU operation failure or monitor microprocessor
    reception failure
Error type
Expression of Central Icon LED
Monitor temperature 
failure
Flashes once 
(High speed)
H: ON
L: OFF
If the panel temperature is 60
°C or more for 15s or more in a row, 
CAUTION appears on the OSD (flashes in red in the lower right 
screen).
If the panel temperature is 60
°C or more for 25s or more in a row, 
error standby is activated.
(MONITOR MAX TEMP on page 13/21 of the adjustment process: 
Change AD value for temperature failure): Thermistor
Main failure
Flashes 3 times 
(High speed)
H: ON
L: OFF
Main microprocessor detection error (CPU temperature error, etc.)
Details are displayed on page 1/21 of the adjustment process for 
the main microprocessor.