LC-40/46LE811E, LC-40/46LE821E (1st Edition)
3 – 9
10. Public Mode
1. Starting the Public Mode
• There are two following ways to display the PUBLIC Mode setting screen.
1) Method of needing password
a) Turn off the power, refer to “3. Method of shuts down for Power supply”
b) While holding down the “INPUT” and “Volume (+)” keys on the set at once, touch the power supply key on the set.
Please separate the finger from the power supply key when boot-up is confirmed with lighting of a central icon etc.
After a while, value of Public Mode appears on the screen.
c) Display the Pass Word input screen.
Operation procedure
• The initial input position is the digit at the left end.
• For the numeric keys “0” to “9” of R/C, key input is accepted.
Input of the other keys is prohibited.
• Change “—” to “ * ” by inputting the numeric key at the input position, and shift the input position rightward one digit.
• When three digits are completely input, the Pass Word is judged.
d) Check the Pass Word by inputting three digits.
If the Pass Word “0” “2” “7”, it shifts to the PUBLIC Mode setting screen.
In another case, the screen is erased, and it operates in the ordinary mode.
2. Exiting the Public Mode Setting screen
• There are two following ways to exit the Public Mode setting screen.
1) Turn off the power.
2) Select “Execution” in the PUBLIC_Mode to execute it.
Activate the restart under the set content.
Here, the START input SOURCE setting is excluded since this item is referred to only when the power is turned on.
3. Set value of the Public Mode
• When the shipment setting is done, a set each value in Public Mode is initialized.
(PUBLIC MODE in the process mode Setting of a flag is also initialized)
• Separately, the shipment beginnings when all except for each set value in Public Mode is initialized are provided for a process mode.
(INDUSTRY INIT (-Public))
• Only when turning on the PUBLIC MODE item, each setting is effective.
• After it decides it with EXECUTE, it AC OFF/ON it to reflect a set value.
Public Mode
Public Mode
Public Mode
LC-40/46LE811E, LC-40/46LE821E (1st Edition)
3 – 10
4. Basic operation in the Public Mode
          Public Mode setting screen.
5. Operation after “RESET”
Select “RESET” in the PUBLIC Mode, and it operates as follows when it is executed (refer to the basic operation).
• The set contents in the PUBLIC mode are initialized.
• It does not exit the PUBLIC mode.
• If “EXCUTE” is not executed, the content that does RESET is not reflected.
6. Setting items (* Item names and selective items are expressed in English.)
1) Power ON fixed [POWER ON FIXED]
If the power button is pressed in the ordinary mode in setting to “FIXED_ALL” and “FIXED_BODYKEY”, the caution is displayed for 5 seconds.
* The OSD display is an example.
If another ODS is previously displayed, the status is reset (MENU or similar).
Vol (+/-) or Cursor ( / )
Change or execution of the set value.
CH (
/
) or Cursor ( / )
Movement to the selected item.
Decision (ok)
Execution (Used by the items “Execution” and “RESET”.)
Public Mode
POWER ON FIXED 
[VARIABLE]
SHUT DOWN MODE 
[NORMAL]
MAXIMUM VOLUME 
[60]
VOLUME FIXED 
[VARIABLE]
VOLUME FIXED LEVEL 
[20]
RC BUTTON 
[RESPOND]
PANEL BUTTON 
[RESPOND]
MENU BUTTON 
[RESPOND]
AV POSITION FIXED 
[VARIABLE]
ON SCREEN DISPLAY 
[YES]
INPUT MODE START 
[NORMAL]
INPUT MODE FIXED 
[VARIABLE]
LOUD SPEAKER 
[ON]
RC PATH THROUGH 
[OFF]
232C POWON 
[DISABLE]
PUBLIC MODE 
[ON]
RESET
EXECUTE
Option 
“VARIABLE”, “FIXED_ALL”, “FIXED_BODYKEY” or “RCRESPOND” (loop enabled)
Default “VARIABLE”
Function 
• VARIABLE
: “POWER/RECEPTION” key on TV unit or remote control is enabled.
• FIXED_ALL“
: “POWER/RECEPTION” key on TV unit or remote control is disabled. 
• FIXED_BODYKEY : only the “MAIN POWER” key on TV unit is disabled (the remote control is enabled).
• RC RESPOND
: the main unit’s POWER switch toggles between ON and Standby (the same operation by 
the remote control).
Key disabled when set 
other than default
• OFF TIMER (SLEEP) (* Only when setting to FIXED_ALL)
Remarks 
• When selecting to “FIXED_ALL”, function related standby factors (see below) doesn't work. and not selecting
   OFF TIMER (Sleep)
   No operation OFF
   No signal OFF (including the power management)
* These items does not exist according to the model.
When power button on the main unit is pressed
       When power button on R/C is pressed
No Power off by power button.
No Power off by remote control.
LC-40/46LE811E, LC-40/46LE821E (1st Edition)
3 – 11
2) Instantaneous current shutdown setting in turning off the power [SHUT DOWN MODE]
3) Volume maximum level [MAXIMUM VOLUME]
4) Volume fixed [VOLUME FIXED]
5) Volume fixed level [VOLUME FIXED LEVEL]
6) Remote control operation [RC BUTTON]
Option 
“NORMAL” or “QUICK”
Default NORMAL
Function
• This function decides whether scanning digital tuner is enabled or disabled when the power is standby.
 
NORMAL
: Scanning digital tuner is enabled when the power is standby.
QUICK
: Scanning digital tuner is disable 
It is possible to put into the standby state instantaneously due to power off input, when the 
power is standby.
Immediately, state is a complete standby. 
Remarks 
In selecting “QUICK”, the function does not work for the following items (selection impossible.)
• ON TIMER, QUICK START, DIGITAL FIXED, etc.
* These items does not exist according to the model.
Option
0~60 (loop disabled)
Default
60
Function
The volume cannot be increased more than the adjusted value (the main unit’s speaker only).
Remarks
• When setting to 59 or less, only the figure is displayed in the normal mode; the volume bar is not displayed.
• The volume of the headphones is limited. or monitor output 
• The setting is impossible when VOLUME FIXED is set to FIXED.
Option 
“VARIABLE”, “FIXED”, “ACCTRL” or “AC/RCCTRL” (loop enabled)
Default “VARIABLE”
Function 
• VARIABLE
: The volume is not fixed.
• FIXED
: The volume is fixed to the value adjusted in the volume fixed level.
• AC CTRL
: The unit starts at the volume specified in the volume fixed level, when power is turned on in 
the case of the AC-ON only.
• AC/RC CTRL
: The unit starts at the volume specified in the volume fixed level, when power is turned on in 
any case. (AC
→ON, remote control→ON, main unit's key→ON)
Exception 
• In the adjustment process, the volume can be set to any level regardless of this setting.
Disabled key when setting 
to FIXED
• VOLUME UP/DOWN    [both remote control and main unit]
• MUTE 
Remarks 
• [MAXIMUM VOLUME] has priority to [VOLUME FIXED]
* When setting to FIXED, Maximum volume is fixed.
• The volume of the headphones is fixed.
• When setting to “FIXED”, the volume is not displayed in operating Disabled key 
• In menu operation, the main unit's keys (Vol (+/-)) are enabled.
Option
0~60 (loop disabled)
Default
20
Function
The volume is fixed to the adjusted value (the main unit’s speaker only).
Exception
• In the adjustment process, the volume can be set to any level regardless of this setting.
Remarks
• When [VOLUME FIXED] is set to “VARIABLE”, the setting cannot be changed.
Option 
“RESPOND”, “NORESPOND” or “LIMITED” (loop enabled)
Default “RESPOND”
Function
The operation of the remote control’s keys is set.
 
   RESPOND
: the remote control’s keys in the normal state are enabled.
   NO RESPOND
: the remote control’s keys in the normal state are disabled.
The POWER key (RECEPTION/STANDBY key) is also disabled.
   LIMITED 
: only a part of keys (CHANNEL, etc.) is enabled and other keys are disabled.
Exception 
• In the adjustment process mode, inspection mode are enabled regardless of this setting.
• All the keys are enabled regardless of this setting while entering the adjustment process mode, inspection mode 
or Public Mode setting screen.
Remarks 
The enable keys when setting to “LIMITED” are depended on keys of controler for Public.
It is different according to Model.
LC-40/46LE811E, LC-40/46LE821E (1st Edition)
3 – 12
7) Main Unit Operation [PANEL BUTTON]
8) Menu operation [MENU BUTTON]
9) AV position fixed [AV POSITION FIXED]
Option 
“RESPOND” or “NORESPOND” (loop enabled)
Default “RESPOND”
Function 
• RESPOND 
: The main unit’s keys are enabled.
• NO RESPOND
: The main unit’s keys are disabled excluding the POWER key (RECEPTION/STANDBY 
key).
Exception 
• The start operation in the adjustment process mode, inspection mode are enabled regardless of this setting.
• All the keys are enabled regardless of this setting while entering the adjustment process mode, inspection mode 
or Public Mode setting screen.
• For the models with the MENU key on the main unit, menu operation is possible regardless of the setting during 
the initial setting when the power is turned on for the first time.
Option 
“RESPOND” or “NO RESPOND” (loop enabled)
Default “RESPOND”
Function 
The MENU key on the main unit and remote control is decided whether it is enabled or disabled.
Exception
• RESPOND 
: The menu key is enabled.
• NO RESPOND 
: The menu key is disabled.
: The start operation in the adjustment process mode, inspection mode is enabled regard-
less of this setting.
: All the keys are enabled regardless of this setting while entering the process mode, inspec-
tion mode or Public Mode setting screen.
Disabled key excluding 
Menu key when setting to 
not default
All the direct transition keys to menu display (AUTO PRESET, MANUAL MEMORY and others)
* These keys does not exist according to the model.
Remarks 
When setting to “NO RESPOND”
• For the models with the MENU key on the main unit, menu operation is possible regardless of the setting while 
the initial setting when the power is turned on for the first time
Option 
“VARIABLE” or “FIXED” (loop enabled)
Default “VARIABLE”
Function 
• VARIABLE 
: AV position is not fixed.
• FIXED
: AV position is fixed.
: The image/sound adjustment items in the menu are fixed in the selected state.
: When receiving “AV POSITION” of the remote control, only the actual state is displayed, 
and setting is not changed.
Remarks 
• When receiving the sound select direct keys (AV POSITION key, OPC, DOLBY key, etc.), only the actual state is 
displayed; no setting is changed.
* These keys does not exist according to the model.
• The settings for the Public mode are retained after the personal data is initialized, each item for the AV position 
and image/sound adjustment are not initialized.
Page of 19
Display

Click on the first or last page to see other LC-40LE811E (serv.man10) service manuals if exist.