Page  Line  Item 
Description 
Remarks (Adjustment detail, etc.) 
 
[M GAMMA 4-6] 
  9/11 
(Continued) 
6
7
8
9
10
MGAMMA B 5 
MGAMMA R 6 
MGAMMA G 6 
MGAMMA B 6 
MGAMMA WRITE 
0
0
0
0
OFF/ON 
W/B adjustment, gradation 5B adjustment value 
W/B adjustment, gradation 6R adjustment value 
W/B adjustment, gradation 6G adjustment value 
W/B adjustment, gradation 6B adjustment value 
EEP writing of adjustment values 
 
[ETC] 
10/11
1
2
3
4
5
6
7
8
9
10
EEP CLEAR 
EEP CLEAR B 
STAND BY CAUSE RESET 
AUTO INSTALLATION SW 
OPTION 
COUNTRY 
L ERR RESET 
L ERR STOP 
DTV CLR 
I2C-OFF 
OFF/ON 
OFF/ON 
OFF/ON 
0/1
0
(--/EURO/UK/ITALY/FRANCE/RUSSIA) 
0
0/1
0/1
ENTER
Restore NVM data to default values 
Restore NVM data to default values except 
adjustment data 
Clearing of standby cause error list 
0: unfinished    1:finish (The setting takes effect 
the next time the power is turned on.) 
Selected country                                                     
Lamp error counter 
Stops Lamp Error feature  
Restore Digital Module NVM to default values 
BUS STOP 
 
LCD 
11/11
1
2
3
4
5
6
7
OSC FREQ 50 
OSC FREQ 60 
PWM FREQ 50 
PWM FREQ 60 
PWM FREQ 
PWM DUTY 
PWM CTRL 
144
144
1
1
424
227
0
17
 LC-26GA5E
 LC-32GA5E
  LC-32GA8/LC-32BV8
  LC-37GA8/LC-37BV8
4. Special Features
- ERROR STAND-BY CAUSE (Page 1/11) 
  When the unit enters standby due to operational error, total time before the error and the cause of error is recorded
  on EEPROM, if possible. The values can be used to locate the fault for repair.
- EEP CLEAR (Page 10/11)
  Restore NVM data to default values.  
- EEP CLEAR B (Page 10/11)
  Restore NVM data to default values except adjustment data.
5. Video Signal Adjustment Procedure
The adjustment process mode menu is listed in Section 3.
5.1. Signal check
Signal generator level adjustment check (Adjustment to the specified level).
- Composite signal PAL 
:  0.7Vp-p ± 0.02Vp-p (Pedestal to white level)
- 15K Component signal 
:  Y level 
 
0.7Vp-p ± 0.02Vp-p (Pedestal to white level)
  (50Hz) (576i/50Hz)  
   PB, PR level   
0.7Vp-p ± 0.02Vp-p
5.2. Entering the adjustment process mode
Enter the  adjustment process mode according to Section
 1.
5.3.  RF AGC Adjustment
����� ����� �����
������������
����������������������������������
��������������
�������
������������
��
�����������
�����������
�����������
�����������
�������������
�������
����������������������������������������������
����������������������������������������������
����������������������������������������������
����������������������������������������������
���������������������������������
������
�����
����������
������������
���������������������
���������������������
�������
��������
������������
�����������
��������
�������
�������
�������
���
���������������������������������
���
�����
�����������������������������������
������������������������������������������
����������������
�������������������������������������
����������������������������������������������������
���������������������������������������
������������������������������������������������������������������� �
�������������������
�����������������������������������������
���������
����
�����
������������
������������
������������
������������
���������
���������
���������
���
���
���
���
Adjustment Point
Adjustment conditions
 Adjustment procedure
1
Setting
[Signal]
PAL
Field Color Bar
RF signal 
[Terminal]
TUNER
• Feed the PAL color bar signal (E-12ch) to TUNER.
Signal level: 50 ±1dB µV (75Ω LOAD)
2
Auto adjustment 
performance
Adjustment process page 3.
Bring the cursor on [▪RF AGC ADJ] and press [OK].
[▪RF AGC ADJ OK] appears when finished.
�����������������������������
  
↑  100% white
[TUNER]
18
 LC-26GA5E
 LC-32GA5E
LC-32GD9E  
LC-37GD9E
18
 LC-26GA5E
 LC-32GA5E
  LC-32GA8/LC-32BV8
  LC-37GA8/LC-37BV8
5.5. PAL Signal & Tuner Adjustment
5.4. RF AGC Adjustment (SMPTE RF SIGNAL- Alternative Method)
Adjustment Point
Adjustment conditions
 Adjustment procedure
1
Setting
[Signal]
PAL
SMPTE Field Color Bar
RF signal 
[Terminal]
TUNER
• Feed the PAL SMPTE color bar signal (E-12ch) to TUNER.
Signal level: 50 ±1dB µV (75Ω LOAD)
2
Auto adjustment 
performance
Adjustment process page 6.
Bring the cursor on [▪RF AGC ADJ] and press [OK].
[▪RF AGC ADJ OK] appears when finished.
  ↑  100% white
Adjustment Point
Adjustment conditions
 Adjustment procedure
1
Setting
[Signal]
PAL
FULL Field Color Bar
Composite or RF signal 
[Terminal]
EXT3 VIDEO IN
TUNER
• Feed the PAL full field color bar signal (75% color saturation) to 
EXT3 VIDEO IN.
• Feed the RF signal PAL color bar (E-12) to TUNER.
• Make sure the PAL color bar pattern (E-12) has the sync level of 7:3 
with the picture level.
2
Auto adjustment 
performance
Adjustment process page 3.
Bring the cursor on [▪PAL +TUNER  ADJ] and press [OK].
[▪PAL+ TUNER ADJ OK] appears when finished.
  ↑  100% white
�����������������������������
  
↑  100% white
5.6. PAL Signal & Tuner Adjustment (SMPTE RF SIGNAL-Alternative Method)
Adjustment Point
Adjustment conditions
 Adjustment procedure
1
Setting
[Signal]
PAL
FULL Field Color Bar
Composite or 
RF SMPTE  
signal 
[Terminal]
EXT3 VIDEO IN
TUNER
• Feed the PAL full field color bar signal (75% color saturation) to 
EXT3 VIDEO IN.
• Feed the RF signal SMPTE  color bar (E-12) to TUNER.
• Make sure the SMPTE color bar pattern (E-12) has the sync level of 
7:3 with the picture level.
2
Auto adjustment 
performance
Adjustment process page 6.
Bring the cursor on [▪PAL +TUNER  ADJ] and press [OK].
[▪PAL+ TUNER ADJ OK] appears when finished.
  ↑  100% white
  ↑  100% white
[EXT 3]
[TUNER]
[EXT 3]
[TUNER]
[TUNER]
19
 LC-26GA5E
 LC-32GA5E
LC-32GD9E  
LC-37GD9E
19
 LC-26GA5E
 LC-32GA5E
  LC-32GA8/LC-32BV8
  LC-37GA8/LC-37BV8
5.7. ADC Adjustment (Component 15K)
Adjustment Point
Adjustment conditions
 Adjustment procedure
1
Setting
[Signal] (576i/50)
COMP 15K, 50Hz
100% Full Field Color Bar 
[Terminal]
EXT4 [COMPONENT] 
• Feed the COMPONENT 15K 100% full field color bar signal  (100% 
color saturation) to EXT4 COMPONENT IN.
2
Auto adjustment 
performance
Adjustment process page 4.
Bring the cursor on [▪COMP15K  ADJ] and press [OK].
[▪COMP15  ADJ OK] appears when finished.
  ↑  100% white
[EXT 4]
6. White Balance Adjustment
Adjustment procedure Page 7/11 shows the value of adjustment gradation (IN value) and Adjustment procedure Page 
8/11 & 9/11 show adj. offset value (initial value : 0). White balance adjustment is executed adjusting the adj. offset value, 
indicated on Page 8/11 & 9/11.
Condition of the inspection: • Backlight: MAX (+8) [DYNAMIC]
 
 
 
      
  • Colorimeter at screen centre
Adjustment reference device: Minolta CA-210
Tolerance adjustment spec.  ±0.004,     Inspection spec. : ±0.006   (GAMMA 1)
Tolerance adjustment spec.  ±0.002,     Inspection spec. : ±0.004   (GAMMA 2...6)
  
Adjustment: Check that the values on page 7/11 of process adjustment are set as below. If not, change them ac-
cordingly. 
M GAMMA IN 1
160
M GAMMA IN 2
320
M GAMMA IN 3
480
M GAMMA IN 4
640
M GAMMA IN 5 
800
M GAMMA IN 6
960
1- Display the current adjustment status at point 6. (Page 9/11 of process adjustment)
The pattern for checking the adjustment status is toggled by pressing the “6” button on the remote control. (Normal 
OSD display -> “6” -> pattern for check (OSD disappears) -> “6” -> normal OSD display -> …)
2- Read the value of the luminance meter.
3- Change M GAMMA R6/M GAMMA B6 (adjustment offset value) on page 9/11 of process adjustment so that the 
values of the luminance meter approach 
x = 0.272 and y = 0.277.
(Basically, G is not changed. If adjustment fails only with R and B, then G should be reduced. In this case, the weaker 
of R and B must be fixed.)
4- If G is changed in step “3”, change the values of M GAMMA G1 - M GAMMA G5 on pages 8/11 and 9/11 of process 
adjustment as follows. When not changed, go to step “5”.
Offset value of M GAMMA G1 = (Offset value of M GAMMA G6)*(160/960)
   Offset value of M GAMMA G2 = (Offset value of M GAMMA G6)*(320/960)
Offset value of M GAMMA G3 = (Offset value of M GAMMA G6)*(480/960)
Offset value of M GAMMA G4 = (Offset value of M GAMMA G6)*(640/960)
Offset value of M GAMMA G5 = (Offset value of M GAMMA G6)*(800/960)
  ← Black
20
 LC-26GA5E
 LC-32GA5E
LC-32GD9E  
LC-37GD9E
20
 LC-26GA5E
 LC-32GA5E
  LC-32GA8/LC-32BV8
  LC-37GA8/LC-37BV8
���������������
���������������������
��������������������
����������������
��������������������
����������������������������������
����������������������������������������������������
����������������� ����������������������������������������������
���������������������������������������������������������
�������������� ��������������������������������������������������������
������������
����� �����������������������������������������������
����������������������������������������������������������
����������������
��������������������������������������������
����������������
����������������������������������������������������
�������������������������������������������������������������������������������������������������������������
��������������������������������������������������������������������������������������������������������
���������������������������������������������������������������
�������� ����������������������������������������������������������������������������������������������������
����������������������������������������������������������������������������������������������������
��������������������������������������
[FACTORY INIT]
8. Initialization to factory settings
7. QS Temperature NVM Data Confirmation
During servicing of the LCD TV set , by software upgrading or by any cleaning NVM, it’s mandatory select the “Inch 
Setting” in Service Mode, Page 2, according to the size of the TV set.
02/11   [ INIT ]
INPUT 4
PAL
--:--
Factory Init
--
Inch Setting
--
Public Mode
OFF
Center Acutime
00H
RESET
OFF
Backlight Acutime
00H
RESET
OFF
Picture Read Pos X
0
Picture Read Pos Y 
0
Picture Read
OFF
 
Default picture after cleaning NVM.                                        Picture with [Inch Setting] to 32.
02/11   [ INIT ]
INPUT 4
PAL
32:--
Factory Init
--
Inch Setting
32
Public Mode
OFF
Center Acutime
00H
RESET
OFF
Backlight Acutime
00H
RESET
OFF
Picture Read Pos X
0
Picture Read Pos Y 
0
Picture Read
OFF
5- Display the adjustment status of the current point 5. (Each time the “5” button on the remote control is pressed, the 
adjustment status check pattern is toggled.)
(Normal OSD display -> “5” -> Pattern display (OSD disappears) -> “5” -> Normal OSD display ->…)
Change M GAMMA R5/M GAMMA B5 (adjustment offset value) on page 9/11 of process adjustment so that the val-
ues of the luminance meter approach 
x = 0.272 and y = 0.277.
6- Repeat step “5” for GAMMA points 4, 3, 2, and 1.
Page of 9
Display

Sharp LC-37GD9EK (serv.man8) Service Manual ▷ Download

  • DOWNLOAD Sharp LC-37GD9EK (serv.man8) Service Manual ↓ Size: 608.33 KB | Pages: 9 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp LC-37GD9EK (serv.man8) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp LC-37GD9EK (serv.man8) LCD. Information contained in Sharp LC-37GD9EK (serv.man8) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.