5.7. ADC Adjustment (Component 15K)
Adjustment Point
Adjustment conditions
 Adjustment procedure
1
Setting
[Signal] (576i/50)
COMP 15K, 50Hz
100% Full Field Color Bar 
[Terminal]
EXT4 [COMPONENT] 
• Feed the COMPONENT 15K 100% full field color bar signal  (100% 
color saturation) to EXT4 COMPONENT IN.
2
Auto adjustment 
performance
Adjustment process page 4.
Bring the cursor on [▪COMP15K  ADJ] and press [OK].
[▪COMP15  ADJ OK] appears when finished.
  ↑  100% white
[EXT 4]
6. White Balance Adjustment
Adjustment procedure Page 7/11 shows the value of adjustment gradation (IN value) and Adjustment procedure Page 
8/11 & 9/11 show adj. offset value (initial value : 0). White balance adjustment is executed adjusting the adj. offset value, 
indicated on Page 8/11 & 9/11.
Condition of the inspection: • Backlight: MAX (+8) [DYNAMIC]
 
 
 
      
  • Colorimeter at screen centre
Adjustment reference device: Minolta CA-210
Tolerance adjustment spec.  ±0.004,     Inspection spec. : ±0.006   (GAMMA 1)
Tolerance adjustment spec.  ±0.002,     Inspection spec. : ±0.004   (GAMMA 2...6)
  
Adjustment: Check that the values on page 7/11 of process adjustment are set as below. If not, change them ac-
cordingly. 
M GAMMA IN 1
160
M GAMMA IN 2
320
M GAMMA IN 3
480
M GAMMA IN 4
640
M GAMMA IN 5 
800
M GAMMA IN 6
960
1- Display the current adjustment status at point 6. (Page 9/11 of process adjustment)
The pattern for checking the adjustment status is toggled by pressing the “6” button on the remote control. (Normal 
OSD display -> “6” -> pattern for check (OSD disappears) -> “6” -> normal OSD display -> …)
2- Read the value of the luminance meter.
3- Change M GAMMA R6/M GAMMA B6 (adjustment offset value) on page 9/11 of process adjustment so that the 
values of the luminance meter approach 
x = 0.272 and y = 0.277.
(Basically, G is not changed. If adjustment fails only with R and B, then G should be reduced. In this case, the weaker 
of R and B must be fixed.)
4- If G is changed in step “3”, change the values of M GAMMA G1 - M GAMMA G5 on pages 8/11 and 9/11 of process 
adjustment as follows. When not changed, go to step “5”.
Offset value of M GAMMA G1 = (Offset value of M GAMMA G6)*(160/960)
   Offset value of M GAMMA G2 = (Offset value of M GAMMA G6)*(320/960)
Offset value of M GAMMA G3 = (Offset value of M GAMMA G6)*(480/960)
Offset value of M GAMMA G4 = (Offset value of M GAMMA G6)*(640/960)
Offset value of M GAMMA G5 = (Offset value of M GAMMA G6)*(800/960)
  ← Black
20
 LC-26GA5E
 LC-32GA5E
LC-32GD9E  
LC-37GD9E
20
 LC-26GA5E
 LC-32GA5E
  LC-32GA8/LC-32BV8
  LC-37GA8/LC-37BV8
���������������
���������������������
��������������������
����������������
��������������������
����������������������������������
����������������������������������������������������
����������������� ����������������������������������������������
���������������������������������������������������������
�������������� ��������������������������������������������������������
������������
����� �����������������������������������������������
����������������������������������������������������������
����������������
��������������������������������������������
����������������
����������������������������������������������������
�������������������������������������������������������������������������������������������������������������
��������������������������������������������������������������������������������������������������������
���������������������������������������������������������������
�������� ����������������������������������������������������������������������������������������������������
����������������������������������������������������������������������������������������������������
��������������������������������������
[FACTORY INIT]
8. Initialization to factory settings
7. QS Temperature NVM Data Confirmation
During servicing of the LCD TV set , by software upgrading or by any cleaning NVM, it’s mandatory select the “Inch 
Setting” in Service Mode, Page 2, according to the size of the TV set.
02/11   [ INIT ]
INPUT 4
PAL
--:--
Factory Init
--
Inch Setting
--
Public Mode
OFF
Center Acutime
00H
RESET
OFF
Backlight Acutime
00H
RESET
OFF
Picture Read Pos X
0
Picture Read Pos Y 
0
Picture Read
OFF
 
Default picture after cleaning NVM.                                        Picture with [Inch Setting] to 32.
02/11   [ INIT ]
INPUT 4
PAL
32:--
Factory Init
--
Inch Setting
32
Public Mode
OFF
Center Acutime
00H
RESET
OFF
Backlight Acutime
00H
RESET
OFF
Picture Read Pos X
0
Picture Read Pos Y 
0
Picture Read
OFF
5- Display the adjustment status of the current point 5. (Each time the “5” button on the remote control is pressed, the 
adjustment status check pattern is toggled.)
(Normal OSD display -> “5” -> Pattern display (OSD disappears) -> “5” -> Normal OSD display ->…)
Change M GAMMA R5/M GAMMA B5 (adjustment offset value) on page 9/11 of process adjustment so that the val-
ues of the luminance meter approach 
x = 0.272 and y = 0.277.
6- Repeat step “5” for GAMMA points 4, 3, 2, and 1.
21
 LC-26GA5E
 LC-32GA5E
LC-32GD9E  
LC-37GD9E
21
 LC-26GA5E
 LC-32GA5E
  LC-32GA8/LC-32BV8
  LC-37GA8/LC-37BV8
9. Lamp error detection
 
9.1. Functional description
This LCD colour television has a function (lamp error detection) to be turned OFF automatically for safety when the
lamp or lamp circuit is abnormal.
If the lamp or lamp circuit is abnormal, or some other errors happen, and the lamp error detection is executed, the
following occur.
1- The main unit of television is turned OFF 5 seconds after it is turned ON. (The power LED on the front side of 
TV turns from green to red.)
2 - If the situation “1” happens 5 times sequentially, television can not be turned ON. (The power LED remains red.)
9.2. Countermeasures
When television is turned OFF by the lamp error detection mentioned above, it enters the adjustment process with
the power LED red. Entering the adjustment process turns OFF the error detection and turns ON TV. This enables 
the operation check to detect errors in the lamp or lamp circuit.
Check whether “L ERROR RESET” on point 7, page 10/11 of the adjustment process is 1 or more. If it is 1 or more, 
it indicates the lamp error detection was executed. After confirming that the lamp or lamp circuit is normal,  reset 
the lamp error counter pushing “OK” in the R/C. After resetting counter the label  “***OK***”  appears on Screen.
9.3. Reset  standby  cause error list
After confirming that the lamp error counter has been erased, select “STAND BY CAUSE RESET” on point 3, page 
10/11 of the adjustment process and select ON using the right cursor. For execute press “OK” in the R/C and the     
label “***OK***” appears on Screen. 
22
 LC-26GA5E
 LC-32GA5E
LC-32GD9E  
LC-37GD9E
10. Public Mode (Hotel Mode)
10.1 How to Enter in the Public Mode (Hotel Mode).
Turn on the power and enter in the Adjustment Process mode (ADJ1 or Service Mode) as usual.
In the [INIT], Page 2/11 of Service, turns ON the Public Mode option.
Turn off TV by pressing Main Power switch.
While pressing “VOL+”and “P^” keys at the same time, press Main Power switch for more than 2 seconds.
After this sequence the TV will turn on showing the Public Mode setting screen as follows:
Is possible to select each item of function by pressing cursor UP/DOWN keys on the remote control or CH(∧)(∨) keys 
on the LCD TV. 
The setting position of each item of functions is made by pressing cursor RIGHT/LEFT keys on the remote control 
or VOL(+)(-) keys on the LCD TV.
Select  ENTER  position  after  you  set  all  function,  and  press  cursor  RIGHT/LEFT  keys  on  the  remote  control  or 
VOL(+)/(-) keys on the LCD TC for confi rmation.
10.2. Public Mode Settings.
1. POWER ON FIXED  [
VARIABLE FIXED]
When it is set to “FIXED”  the TV is impossible to be switch off by Main Switch or  Remote Control.
2. MAXIMUM VOLUME [
0   60]
Is possible to set the maximum volume at limited level.
3. VOLUME FIXED [
VARIABLE  FIXED]
Is possible to fi x the sound volume at limited level. 
When “FIXED” is selected the sound volume before limited is fi xed.
4.VOLUME FIXED LEVEL  [
0   60]
If “FIXED” has been selected, is possible to set a fi xed volume at the level that is choosen.   
5. RC  BUTTON  [
RESPOND  NO RESPOND]
If “NO RESPOND” is selected, the remote control keys are inoperative.
6.  PANEL BUTTON [
RESPOND  NO RESPOND]
If “NO RESPOND” has been selected, the set´s keys remain deactivated (Except POWER  key).
7. MENU BUTTON [
RESPOND  NO RESPOND]
If “NO RESPOND” has been selected, “MENU” keys on the remote control, is inoperative.
8. ON SCREEN DISPLAY [YES 
 NO]
If “NO” has been selected,  the On Screen Display does not appear.
9.  INPUT MODE START [
 NORMALTV (X)DTVINPUT1INPUT2INPUT3INPUT4 INPUT5INPUT6]
When any other item than “NORMAL” has been selected, the sets will start in a selected input mode at the next 
power-on.
10. INPUT MODE FIXED [
VARIABLE FIXED]
If “FIXED” has been selected, any channels and input modes other than those selected at the start mode cannot be 
picked up.
11. RESET
Cancel all Public Mode settings. (It returns to the factory settings)
12. EXECUTE
After select this item, all positions that has been selected will be set.
MAXIMUM  VOLUME                                        [60] 
VOLUME FIXED                    [VARIABLE]
VOLUME FIXED LEVEL                [0]
RC BUTTON                          [RESPOND]
PANEL BUTTON                    [RESPOND]
MENU BUTTON                     [RESPOND]
ON  SCREEN  DISPLAY                              [YES]
INPUT  MODE  START                            [NORMAL]
INPUT MODE FIXED               [VARIABLE]
RESET 
EXECUTE
  POWER ON FIXED           
  [VARIABLE] 
 
 Public Mode 
Page of 9
Display

Click on the first or last page to see other LC-37GD9EK (serv.man8) service manuals if exist.