Sharp LC-37GD8EK Service Manual / Specification ▷ View online

 
 
 
 
 
Pin Assignments 
 
 
 
Version 1.0 
Issue 12/2008
 
 
 
9
 
 
SHARP ELECTRONICS (UK) LTD 
CE TECHNICAL SUPPORT 
TECHNICAL SERVICES GROUP 
 
 
HDMI 
 
 
PIN#   Signal  
PIN#   Signal  
PIN#   Signal  
1  
TMDS Data 2+  
8  
TMDS Data 0 Shield  
15  
DDC Clock  
2  
TMDS Data 2 Shield  
9  
TMDS Data 0 
16  
DDC Data  
3  
TMDS Data 2 
10  
TMDS Clock+  
17  
Ground  
4  
TMDS Data 1+  
11  
TMDS Clock Shield  
18  
+5V Power  
5  
TMDS Data 1 Shield  
12  
TMDS Clock 
19  
Hot Plug Detect  
6  
TMDS Data 1 
13  
CEC  
20  
SHELL  
7  
TMDS Data 0+  
14  
No Connect  
 
 
 
S-VIDEO 
 
 
 
RS-232C Terminal: 9-pin Mini DIN female connector 
 
Pin No. 
Signal 
Name 
I/O 
Reference 
 
 
Output 
Not connected 
RD 
Receive Data 
Input 
Connected to internal circuit 
3  
SD  
Send Data  
Output 
Connected to internal circuit 
4  
 
 
Input  
Not connected 
5  
SG  
Signal Ground  
 
Connected to internal circuit 
6  
 
 
Input  
Not connected 
7  
 
 
Output  
Not connected 
8  
 
 
Input  
Not connected 
9  
 
 
Output  
Not connected
  
 
 
 
 
 
 
Pin Assignments 
 
 
 
Version 1.0 
Issue 12/2008
 
 
 
10
 
 
SHARP ELECTRONICS (UK) LTD 
CE TECHNICAL SUPPORT 
TECHNICAL SERVICES GROUP 
 
 
RS-232C Terminal: 9-pin D-sub male connector of the DIN-D-sub RS-232C adapter 
 
Pin No.  
Signal  
Name  
I/O  
Reference 
1  
CD  
 
 
Not connected 
2  
RD  
Receive Data  
Input 
Connected to internal circuit 
3  
SD  
Send Data  
Output 
Connected to internal circuit 
4  
ER  
 
 
Not connected 
5  
SG  
Signal Ground  
 
Connected to internal circuit 
6  
 
 
 
Not connected 
7  
 
 
 
Not connected 
8  
 
 
 
Not connected 
9  
CI  
 
 
Not connected
 
 
RS-232C Cable recommended connection: 
9-pin D-sub female connector 
 
 
Note 
 
Depending on the controlling device used, it may be necessary to connect Pin 4 and Pin 6 
on the controlling device (e.g. PC).
 
 
 
 
 
 
 
Maintenance Procedure 
 
 
 
Version 1.0 
Issue 12/2008
 
 
 
11
 
 
SHARP ELECTRONICS (UK) LTD 
CE TECHNICAL SUPPORT 
TECHNICAL SERVICES GROUP 
 
 
Cleaning the LCD  
 
Ensure you unplug the power cord before cleaning the LCD.  
 
The cabinet as well as the operation panel is made of plastic. Avoid 
using benzene or thinner, as these can damage the finish on the 
cabinet.  
 
Do not use volatile agents such as insecticides on the LCD. Do not 
attach rubber or plastic items on the LCD for long periods of time. 
The effects of some of the agents in the plastic may cause damage 
to the quality or finish of the LCD.  
 
Wipe off dirt gently with a soft flannel cloth.  
 
When the dirt is hard to remove, soak a cloth in a neutral detergent 
diluted with water, wring the cloth well and then wipe the LCD.  
Strong cleaning detergents may discolour, warp or damage the coating on the LCD. 
Ensure you test on a small, inconspicuous area on the LCD before using.  
 
 
Cleaning the exhaust and intake vents  
 
Use a vacuum cleaner to clean dust from the exhaust vent and the intake vent.
 
 
 
 
 
Firmware Upgrade Procedure 
 
 
 
Version 1.0 
Issue 12/2008
 
 
 
12
 
 
SHARP ELECTRONICS (UK) LTD 
CE TECHNICAL SUPPORT 
TECHNICAL SERVICES GROUP 
 
 
Firmware Upgrade Procedure 
 
There are 3 methods to update software in the VCTp: I2C method, RS-232C HyperTerminal 
and RS-232C Tera Term method. 
 
RS-232C method is allowed when the TV is working properly and the action should be 
only software upgrade. 
 
I2C method is required when the VCTp flash is empty or corrupted (it means, any 
software inside IC running). 
 
RS-232C Method Description (HyperTerminal) 
 
Part Number 
Description 
Price Rank 
QCNWGA015WJPZ 
Connecting Cord 
AK 
 
The hardware tools requirement are: 
1.  A Modem-null (Cross type) DB9 female to DB9 female cable. 
2.  An adapter DB9 male to mini-Din 9 pin male cable (Sharp Code: QCNWGA015WJPZ) 
3.  Make the connections as indicated in the figure: 
 
 
 
Before using RS-232C updating method is necessary to configure Terminal PC software. 
HyperTerminal has been selected as a Terminal software because it’s included in all Windows 
versions as an accessory, and you can find it inside 
“Accessories\Communications” folder 
(Windows XP).  
For this reason, please follow carefully the next steps: 
1. 
First time HyperTerminal is used, it’s necessary to configure some settings. Follows next 
action to configure two connection: low speed (9600bps) and high speed (115200bps). 
2. 
Create a New Connection fi le with name “P55_9600bps”. 
3.  Select a free COM port and select the Port Settings properties as follows: 
Page of 25