DOWNLOAD Sharp LC-32FH510E (serv.man7) Service Manual ↓ Size: 544.19 KB | Pages: 12 in PDF or view online for FREE

Model
LC-32FH510E (serv.man7)
Pages
12
Size
544.19 KB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD / Service Adjustments
File
lc-32fh510e-sm7.pdf
Date

Sharp LC-32FH510E (serv.man7) Service Manual ▷ View online

22
6. Video Signal Adjustment Procedure
6.1. RGB SCART ADC
1. Enter in Service mode.
2. Press “▼” until selecting “ADC ADJUST” option.
3. Press “OK”.
4. “ADC ADJUST” menu appears. 
5. Press “▼” until selecting “ADJUST” option.
6. Press “►”until selecting “Internal Signal”.
7. Press “▲”until selecting “MODE” option.
8. Press “►”until selecting “RGB”.
9. Press “▼” until selecting “AUTO ADC” option.
10. Press “►”, the adjustment starts.
11. “SUCCESS” appears when the adjustments fi nish.
12. Exit of Service mode.
6.2. COMPONENTS ADC
1. Enter in Service mode.
2. Press “▼” until selecting “ADC ADJUST” option.
3. Press “OK”.
4. “ADC ADJUST” menu appears.
5. Press “▼” until selecting “ADJUST” option.
6. Press “►”until selecting “Internal Signal”.
7. Press “▲”until selecting “MODE” option.
8. Press “►”until selecting “YPbPr(SD)” or “YPbPr(HD)”
9. Press “▼” until selecting “AUTO ADC” option.
10. Press “►”, the adjustment starts.
11. “SUCCESS” appears when the adjustments fi nish.
Note: both SD and HD are adjusted.
12. Exit of Service mode.
LC-32FH500 
LC-32FH510
23
7. White Balance Adjustment
Condition: AV MODE= Dynamic (backlight at max.).
•  Adjustments reference device: Minolta CA-210
•  Adjustments target: x=0.272, y=0.277
  High: adjustments spec ±0.001, inspection spec: ±0.002
  Low:  adjustments spec ±0.002, inspection spec: ±0.004
1. Press “▼” until selecting “GAMMA” option.
2. Press “OK”.
3.  “GAMMA” menu appears.
4. Press “▼” until selecting “MGAMMA RESET”.
5. Press “►”, to restore default values.
6.  “MGAMMA RESET SUCCESS” appears.
7.  Press “P+” to increase one page.
8.  Press “1”, appears “Internal Adjustments Pattern 1”.
9.  Hold the default value for “MGAMMA G1”.
(Note: next, try to get the (x, y) adjustments target,
 changing “MGAMMA R1” and “MGAMMA B1” as follow).
10. Press “▼” until selecting “MGAMMA R1”.
11.  Press “◄ ►” until you obtain the desired value.
12. Press “MENU” to return to previous menu.
13. Press “▼” until selecting “MGAMMA B1”.
14. Press “◄ ►” until you obtain the desired value.
15. Press “MENU” to return to previous menu.
(Note: In case of not being possible to achieve the desired 
(x, y) target, try to get it by changing also the “MGAMMA G1”)
16. Press “2”, appears “Internal Adjustments Pattern 2”.
17. Repeat from step 9 to 15 for the “MGAMMA R2” and “MGAMMA B2”.
18. Press “3”, appears “Internal Adjustments Pattern 3”.
19. Repeat from step 9 to 15 for the “MGAMMA R3” and “MGAMMA B3”.
20. Press “4”, appears “Internal Adjustments Pattern 4”.
21. Repeat from step 9 to 15 for the “MGAMMA R4” and “MGAMMA B4”.
22. Press “5”, appears “Internal Adjustments Pattern 5”.
23. Repeat from step 9 to 15 for the “MGAMMA R5” and “MGAMMA B5”.
24. Press “6”, appears “Internal Adjustments Pattern 6”.
25. Repeat from step 9 to 15 for the “MGAMMA R6” and “MGAMMA B6”.
26. Press “▼” until selecting “MGAMMA WRITE”.
27. Press “►”, to save the new values.
28. “MGAMMA WRITE SUCCESS” appears.
NOTE:
For activating the W/B fl ag, only is necessary to send the order MGAMMA WRITE. After this action, the “W” W/B 
fl ag will change to “1”. 
LC-32FH500 
LC-32FH510
24
8. Initialization to factory setting
Caution: When the factory settings have been made, all user setting data, including the channel settings, are initialized.
(The adjustments done in the adjustment process mode are not initialized.) Keep this in mind when initializing these settings.
1. Enter in Service mode.
2. Press “▼” or “▲” key until selecting INIT.
3. Press OK key.
4. INIT menu appears and “Factory init” option is selected.
5. Press  “◄” or “►” until selecting the option desired (EURO/RUSSIA/SWEDEN/UK/EAST EUROPE).
6. Press OK key and initialization starts.
7. OK, EURO message appears for EURO option when the setting is complete.
OK, RUSSIA message appears for RUSSIA option when the setting is complete.
OK, SWEDEN message appears for SWEDEN option when the setting is complete.
OK, UK message appears for UK option when the setting is complete.
OK, EAST EUROPE message appears for EAST EUROPE option when the setting is complete.
Note: Never turn the power off during initialization.
To exit the adjustment process mode, unplug the AC power cord from the outlet to forcibly turn off the power.
The following settings will be back to their factory ones.
•  User settings
•  Channel data (e.g. broadcast frequencies)
•  Maker option setting
•  Password data
LC-32FH500 
LC-32FH510
25
9. Lamp error detection
1. Function description
This LCD colour television has a function (lamp error detection) to be turned OFF the TV set automatically for 
safety criteria when the lamp or lamp circuit is abnormal.
If the lamp or lamp circuit is abnormal, or some other errors happen, and the lamp error detection is executed, the 
following occurs:
a. The TV set is turned OFF automatically 20 seconds after it is turned ON by the user.
(The power LED on the front side of TV turns from green to red)
b. If the situation “a.” happens 5 times sequentially, it becomes impossible to turn on the power.
(The power LED turns from green to red and keeps blinking in red).
 
LED Flashing timing  
 
 
 
 
 
 
                                                   
260 ms
     1 s 
 
Red → 260 ms
  
 
Off  → 1s
2. Countermeasures
a. Checking with [L Error Check Off]. Repair the problem that produces the LAMP ERROR. The TV remains 
with power LED blinking until K mode is forced by local keyboard, in order to disable the LAMP ERROR detec-
tion. To disable the LAMP ERROR feature is necessary enter in K mode by pressing “VOL DOWN” and “b” 
keys at same time when the AC cord is plugged in.
b. Resetting the LAMP ERROR counter. After the lamp and lamp circuit are found out of trouble, the LAMP 
ERROR counter should be reset. If a LAMP ERROR is detected fi ve consecutive times, the power cannot be 
turned on.
Method 1: Using the cursor (UP/DOWN) key, move to the cursor to [L Error Reset] on Line 6 of ETC Menu Fig 
4. With the cursor (LEFT/RIGHT) keys reset the value to “0”.
Method 2: In the case the TV is not blocked (less than 5 consecutive errors), switch on the Set. After 30 minutes 
working, the LAMP ERROR counter will be reset automatically.
LC-32FH500 
LC-32FH510
Page of 12
Display

Click on the first or last page to see other LC-32FH510E (serv.man7) service manuals if exist.