DOWNLOAD Sharp LC-24LE210E (serv.man14) Service Manual ↓ Size: 535.15 KB | Pages: 12 in PDF or view online for FREE

Model
LC-24LE210E (serv.man14)
Pages
12
Size
535.15 KB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD / Service Adjustments
File
lc-24le210e-sm14.pdf
Date

Sharp LC-24LE210E (serv.man14) Service Manual ▷ View online

20
LC-24LE210 
LC-24LE220
Page
Line
Sub
Page
Item
Description
Remarks (adjustment details, etc.)
01/17
[SHARP FACTORY MENU
7
ETC
EEP, Autoinstallation, Op-
tion, Country, L Error...
Press “OK” to enter to ETC Submenu
09/17
EEP Clear
Press “
” to
 
Clear NVM data
EEP Clear B
Press “
” to Clear NVM data (except adjustments area).
Standby cause reset
“OK“ will be displayed 
Press “
” to Reset of STANDBY CAUSE.
Autoinstallation SW
Off
On: Pending to execute on next power on. Off: Not required.
Pattern
0
Selection of internal pattern from 0 up to 6…
L Error Reset
0
Press “
” to LAMP ERR RESET. Initialization of L_ERR.
L Error Check 
On
L_ERR detection. ON: activated. OFF: deactivated.
I2C OFF
Off
I2C BUS status. On: free BUS. Off: Normal. 
Sharp protocol
On
Remote Control Protocol. On: SHARP Off: MSTAR.
8
PUBLIC MODE (1/2)
PUBLIC MODE Submenu
Press  “OK”  to  enter  to  PUBLIC  MODE  Sub-
menu
10/17
Power On fi xed
Variable
Press “
”  or  “
” to change Variable/Fixed.
Maximum volume
60
Press “
”  or  “
” to change 0/60.
Volume fi xed
Variable
Press “
”  or  “
” to change Variable/Fixed.
Volume fi xed Level
20
 Press “
”  or  “
” to change 0/60.
RC button
Respond
Press “
”  or  “
” to change Respond/No respond.
Panel button
Respond
Press “
”  or “
” to change Respond/No respond.
Menu button
Respond
Press “
”  or  “
” to change Respond/No respond.
On screen display
On
Press “
”  or  “
” to change On/Off.
Input mode start
Normal
Press “
”  or  “
” to change Normal/TV/SCART/…
Input mode fi xed
Variable
Press “
”  or  “
” to change Variable/Fixed.
Input TV mode program 
number
Normal
Press “
”  or  “
” to change Normal → 1 → 2 ...999 
→ Normal).
RC path through
Off
Press “
”  or  “
” to change On/Off (required external 
module)
PUBLIC MODE (2/2)
PUBLIC MODE Submenu
11/17 Hotel 
mode
Off
Press “
”  or  “
” to change On/Off.
Reset
“OK“ will be displayed
Press “
”  or “
” to return to factory settings.
Execute
“OK“ will be displayed
Press “
”  or “
” to confirm.
9
SMART 
LOADER
SMART LOADER Sub-
menu
Press “OK” to enter to SMART LOADER Sub-
menu
12/17
Save settings to USB
(“OK“  or  “NO  USB  drive 
available, please check 
and/or insert USB dri...” 
will be displayed).
Press “
”  or “
” to Save.
(“OK” or “NO USB drive available, please check 
and/or insert USB dri…” will be displayed).
Load settings from USB
(“OK,  reboot  TV  set“  or 
“NO USB drive available, 
please check and/or in-
sert USB dri...” will be dis-
played).
Press “
”  or “
” to Load.
10
ADC ADJUST
ADC ADJUST Submenu
Press “OK” to enter to ADC ADJUST Submenu
13/17
MODE
YPbPr(SD)
Press
 “◄”  or  “►” to change RGB/YPbPr(SD)/ YPbPr(HD)/ PC-RGB.
ADJUST
External signal
Press “
”  or  “
” to change Internal signal/External signal. 
External: factory. Internal: service
R-GAIN
80
Press “
”  or  “
” for manual adjustment.
G-GAIN
70
Press “
”  or  “
” for manual adjustment.
21
LC-24LE210 
LC-24LE220
Page
Line
Sub
Page
Item
Description
Remarks (adjustment details, etc.)
01/17
[SHARP FACTORY MENU
ADC ADJUST (continued)
ADC ADJUST Submenu
Press “OK” to enter to ADC ADJUST Submenu
10
13/17
B-GAIN
80
Press “◄”  or  “►” for manual adjustment.
R-OFFSET
128
Press “◄”  or  “►” for manual adjustment.
G-OFFSET
128
Press “◄”  or  “►” for manual adjustment.
B-OFFSET
128
Press “◄”  or  “►” for manual adjustment.
AUTO ADC
“SUCCESS” or ”Fail will be displayed
Press “◄”  or  “►” for automatic adjustment in each mode.
11
GAMMA (1/3)
GAMMA Submenu
Press “OK” to enter to GAMMA Submenu
14/17
MGAMMA IN1
40
W/B adjustment, gradation 1 input setting.
MGAMMA IN2
80
W/B adjustment, gradation 2 input setting.
MGAMMA IN3
120
W/B adjustment, gradation 3 input setting.
MGAMMA IN4
160
W/B adjustment, gradation 4 input setting.
MGAMMA IN5
200
W/B adjustment, gradation 5 input setting.
MGAMMA IN6
240
W/B adjustment, gradation 6 input setting.
MGAMMA WRITE
“SUCCESS” will be displayed
Press “◄”  or  “►” for EEP writing of adjustment values.
MGAMMA RESET
“SUCCESS” will be displayed
Press “◄”  or  “►” for Initialization of adjustment values.
GAMMA (2/3)
GAMMA Submenu
15/17
MGAMMA R1
132
W/B adjustment, gradation 1R adjustment value.
MGAMMA G1
118
W/B adjustment, gradation 1G adjustment value.
MGAMMA B1
146
W/B adjustment, gradation 1B adjustment value.
MGAMMA R2
276
W/B adjustment, gradation 2R adjustment value.
MGAMMA G2
255
 W/B adjustment, gradation 2G adjustment value.
MGAMMA B2
308
W/B adjustment, gradation 2B adjustment value.
MGAMMA R3
418
W/B adjustment, gradation 3R adjustment value.
MGAMMA G3
385
W/B adjustment, gradation 3G adjustment value.
MGAMMA B3
474
W/B adjustment, gradation 3R adjustment value.
MGAMMA WRITE
“SUCCESS” will be displayed
Press “◄”  or  “►” for EEP writing of adjustment values.
GAMMA (3/3)
W/B ADJUST Submenu
16/17
MGAMMA R4
559
W/B adjustment, gradation 4R adjustment value.
MGAMMA G4
520
W/B adjustment, gradation 4G adjustment value.
MGAMMA B4
643
W/B adjustment, gradation 4B adjustment value.
MGAMMA R5
701
W/B adjustment, gradation 5R adjustment value.
MGAMMA G5
655
W/B adjustment, gradation 5G adjustment value.
MGAMMA B5
807
W/B adjustment, gradation 5B adjustment value.
MGAMMA R6
845
W/B adjustment, gradation 6R adjustment value.
MGAMMA G6
793
W/B adjustment, gradation 6G adjustment value.
MGAMMA B6
998
W/B adjustment, gradation 6R adjustment value.
MGAMMA WRITE
“SUCCESS” will be displayed
 Press “◄”  or  “►” for EEP writing of adjustment values.
12
SYSTEM INFORMATION
SYSTEM INFORMATION 
Submenu
Press “OK” to enter to SYSTEM INFORMATION Sub-
menu (Only for Engineering purpose, don’t use)
17/17
NOISE LEVEL
0
Informative (changing).
GLOBAL MOTION
0
Informative (changing).
BIT RATE
0
 Informative.
Scan name search
2
Changeable between 0 and 255.
VPS code
FFFF
 Informative.
830/1 code
FFFF
 Informative.
830/2 code
FFFF
 Informative.
Top TXT enabled
1
 Press “◄”  or “►” to change 0/1.
CEC
off
 Press “◄”  or “►” to change off/on.
22
LC-24LE210 
LC-24LE220
6. Video Signal Adjustment Procedure
6.1. RGB SCART ADC
1. Enter in Service mode.
2. Press “▼” until selecting “ADC ADJUST” option.
3. Press “OK”.
4. “ADC ADJUST” menu appears. 
5. Press “▼” until selecting “ADJUST” option.
6. Press “►”until selecting “Internal Signal”.
7. Press “▲”until selecting “MODE” option.
8. Press “►”until selecting “RGB”.
9. Press “▼” until selecting “AUTO ADC” option.
10. Press “►”, the adjustment starts.
11. “SUCCESS” appears when the adjustments fi nish.
12. Exit of Service mode.
6.2. COMPONENTS ADC
1. Enter in Service mode.
2. Press “▼” until selecting “ADC ADJUST” option.
3. Press “OK”.
4. “ADC ADJUST” menu appears.
5. Press “▼” until selecting “ADJUST” option.
6. Press “►”until selecting “Internal Signal”.
7. Press “▲”until selecting “MODE” option.
8. Press “►”until selecting “YPbPr(SD)” or “YPbPr(HD)”
9. Press “▼” until selecting “AUTO ADC” option.
10. Press “►”, the adjustment starts.
11. “SUCCESS” appears when the adjustments fi nish.
Note: both SD and HD are adjusted.
12. Exit of Service mode.
6.3. PC IN RGB ADC
1. Enter in Service mode.
2. Press “▼” until selecting “ADC ADJUST” option.
3. Press “OK”.
4. “ADC ADJUST” menu appears. 
5. Press “▼” until selecting “ADJUST” option.
6. Press “►”until selecting “Internal Signal”.
7. Press “▲”until selecting “MODE” option.
8. Press “►”until selecting “PC-RGB”.
9. Press “▼” until selecting “AUTO ADC” option.
10. Press “►”, the adjustment starts.
11. “SUCCESS” appears when the adjustments fi nish.
12. Exit of Service mode.
23
LC-24LE210 
LC-24LE220
7. White Balance Adjustment
Condition: AV MODE= Dynamic (backlight at max.).
•  Adjustments reference device: Minolta CA-210
•  Adjustments target: x=0.300, y=0.310
  High: adjustments spec ±0.001, inspection spec: ±0.002
  Low:  adjustments spec ±0.002, inspection spec: ±0.004
1. Press “▼” until selecting “GAMMA” option.
2. Press “OK”.
3.  “GAMMA” menu appears.
4. Press “▼” until selecting “MGAMMA RESET”.
5. Press “►”, to restore default values.
6.  “MGAMMA RESET SUCCESS” appears.
7.  Press “P+” to increase one page.
8.  Press “1”, appears “Internal Adjustments Pattern 1”.
9.  Hold the default value for “MGAMMA G1”.
(Note: next, try to get the (x, y) adjustments target,
 changing “MGAMMA R1” and “MGAMMA B1” as follow).
10. Press “▼” until selecting “MGAMMA R1”.
11.  Press “◄ ►” until you obtain the desired value.
12. Press “MENU” to return to previous menu.
13. Press “▼” until selecting “MGAMMA B1”.
14. Press “◄ ►” until you obtain the desired value.
15. Press “MENU” to return to previous menu.
(Note: In case of not being possible to achieve the desired 
(x, y) target, try to get it by changing also the “MGAMMA G1”)
16. Press “2”, appears “Internal Adjustments Pattern 2”.
17. Repeat from step 9 to 15 for the “MGAMMA R2” and “MGAMMA B2”.
18. Press “3”, appears “Internal Adjustments Pattern 3”.
19. Repeat from step 9 to 15 for the “MGAMMA R3” and “MGAMMA B3”.
20. Press “4”, appears “Internal Adjustments Pattern 4”.
21. Repeat from step 9 to 15 for the “MGAMMA R4” and “MGAMMA B4”.
22. Press “5”, appears “Internal Adjustments Pattern 5”.
23. Repeat from step 9 to 15 for the “MGAMMA R5” and “MGAMMA B5”.
24. Press “6”, appears “Internal Adjustments Pattern 6”.
25. Repeat from step 9 to 15 for the “MGAMMA R6” and “MGAMMA B6”.
26. Press “▼” until selecting “MGAMMA WRITE”.
27. Press “►”, to save the new values.
28. “MGAMMA WRITE SUCCESS” appears.
NOTE:
For activating the W/B fl ag, only is necessary to send the order MGAMMA WRITE. After this action, the “W” W/B 
fl ag will change to “1”. 
Page of 12
Display