Sharp LC-22LE510K (serv.man2) Service Manual ▷ View online
81
LC-19LE510
LC-22LE510
LC-24LE510
26.2.
CI Module Problem
Problem: CI is not working when CI module inserted.
Possible causes: Supply, supply control pin, detect pins, mechanical positions of pins
CI supply should be 5V when CI module inserted. If it is not 5V please check CI_POWER_CTRL, this pin
should be low.
should be low.
Please check mechanical positions of CI module.
Detect ports should be low. If it is not low please check CI connector pins, CI module pins and 3V3_VCC on
MB60.
26.2 CI Module Problem
82
LC-19LE510
LC-22LE510
LC-24LE510
26.3.
Led Blinking Problem
Problem: LED blinking, no other operation
This problem indicates a short on Vcc voltages. Protect pin should be logic high while normal operation.
When there is a short circuit protect pin will be logic low. If you detect logic low on protect pin, unplug
the TV set and control voltage points with a multimeter to find the shorted voltage to ground.
When there is a short circuit protect pin will be logic low. If you detect logic low on protect pin, unplug
the TV set and control voltage points with a multimeter to find the shorted voltage to ground.
83
LC-19LE510
LC-22LE510
LC-24LE510
26.4.
IR Problem
Problem: LED or IR not working
Check LED card supply on MB60 chassis.
84
LC-19LE510
LC-22LE510
LC-24LE510
26.5.
Keypad Touchpad Problems
Problem: Keypad or Touchpad is not working
Check keypad supply and KEYBOARD pin on MB60.