Sharp LC-22LE22E Service Manual ▷ View online
5.2. Features
6-W/ch into an 8-Ω Loads at 10% THD+N From a 10-V Supply
12-W into a 4-Ω Mono Load at 10% THD+N From a 10-V Supply
87% Efficient Class-D Operation Eliminates Need for Heat Sinks
Wide Supply Voltage Range Allows Operation from 8 V to 26 V
Filter-Free Operation
SpeakerGuard™ Speaker Protection Includes Adjustable Power Limiter plus DC
Protection
Flow Through Pin Out Facilitates Easy Board Layout
Robust Pin-to-Pin Short Circuit Protection and Thermal Protection with Auto
Recovery Option
Excellent THD+N / Pop-Free Performance
Four Selectable, Fixed Gain Settings
Differential inputs
5.3. Absolute Ratings
5.3.1.
Electrical Characteristics
5.3.2.
Operating Specifications
5.4. Pinning
6. POWER STAGE
The DC voltages required at various parts of the chassis and panel are provided by a
main power supply unit. MB60 chassis can operate with IPS60, IPS16, IPS17, PW26,
PW27 as main power supply and also with 12V adaptor.
main power supply unit. MB60 chassis can operate with IPS60, IPS16, IPS17, PW26,
PW27 as main power supply and also with 12V adaptor.
CN706 is used for IPS60, IPS16 and IPS17 and CN1 is used for PW26 and PW27.
JK9 is used for the adapter option and also CN705 inverter socket or DB32 chassis with
CN706 is used to supply backlight.
CN706 is used to supply backlight.
The power supplies generate 18V, 12V, 5V, 3,3V and 12V, 5V, stand by mode DC
voltages. Power stage which is on-chassis generates 5V, 3V3 stand by voltage and 12V,
8V, 5V, 3V3, 2.5V, 1,8V and 1,2V supplies for other different parts of the chassis. Chassis
block diagram is indicated below.
voltages. Power stage which is on-chassis generates 5V, 3V3 stand by voltage and 12V,
8V, 5V, 3V3, 2.5V, 1,8V and 1,2V supplies for other different parts of the chassis. Chassis
block diagram is indicated below.
The blocks on power block diagram is using dependent to main supply. For PW26 and
PW27 just common blocks are enough for proper operation.
PW27 just common blocks are enough for proper operation.
For IPS16, IPS17, IPS60 below blocks must work properly.
For adopter case also below blocks are necessary.