13
15JF-25H
3.2.3. Select “HTL-VOL” by using channel up/down buttons.
3.2.4. Set the value according to your necessities by using volume up/down buttons.
3.2.5. Change initial value from “0” (off ) to “1” (on).
3.2.6. Note: If you do not need to set up  Hotel Mode  “HTL-PRG” get out from Service Mode (To exit the Service
                  Mode press the stand-by button on the remote control or turn the receiver off with the mains switch).
3.3. Hotel Mode “HTL-PRG” (Fixing start up program when the TV Set is switched on)
3.3.1. Initial value: 255. Range: 0 to 255. Service Mode indication: HTL-PRG.
3.3.2. To activate this Hotel Mode it is necessary activate previously Hotel Mode “HTL”.
3.3.4. Select “HTL-PRG” by using channel up/down buttons.
3.3.3. The initial value to 255, ensures that the TV Set starts up in the same program number that it was been
         displayed before turn it off.
3.3.4 If you want to fix other program number proceed as follows set the value according to your necessities by
        using  volume up / down buttons. Use values between 0 to 99. In this way, the new program number appear
         fixed when you start up the TV set.
Example: If you would like to set starting program number “2”, change from 255 to 2.
    3.3.5. Get out from Service Mode (To exit the Service Mode press the stand-by button on the remote control or turn
       the receiver off with the mains switch).
15JF-25H
14
CHASSIS LAYOUTS
Mother Unit
CRT Unit
15
15JF-25H
LED FLASHING CODES
      PURPOSE:                         The led indicates the power mode,ocurred I
2
C error and On timer
INPUT:
- Current power mode
- I
2
C Errors
- On timer
Processing:
- If in STAND-BY mode and On timer in-active then switch LED off.
- If in STAND-BY and On timer active
     set LED to blinking, (switch on and off at 1 Hz with a 50 % duty cycle).
- If in POWER-ON mode, switch LED on.
- If an I
2
C error occurred, let the LED blink at 1 Hz, 50 % duty cycle.
  For the blinking times see the Table below.
Note:
Only when an I
2
C error occurs for a number of times, or for a number of seconds,
the I
2
C error is handled by the system (that is ,only then the set will go to stand-by,
the led starts blinking).
Table Error LED blinking times
0
1
2
3
4
5
6
Y
X
10
1
2
3
4
5
6
7
8
9
7
 PRINTED WIRING BOARDS
F 7341N0 PWB. Components side.
IC/Module Name
Slave Address
Bus Error LED Remarks
Ref. No.
Blinking Time
M24C04 or M24C08
A0,A2
2
512x8 EEPROM or 1024x8 EEPROM IC1002
TDA935x/6x/8x
8A
3
Address of internal TV processor
IC801
VTST6HD64 or
C0
6
PLL Tuner
TU201
CTF551
C0
6
15JF-25H
16
F7340N6 PWB. Component side
X
22
23
24
25
17
18
19
20
21
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
Y
19
18
17
16
15
14
13
12
25
24
23
22
21
20
Page 17
Page of 44
Display

Click on the first or last page to see other 15FS-25H (serv.man3) service manuals if exist.