Electrical Adjustments
Version 1.3
Issue 04/2006
45
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
No.
Adjustment Items
Adjustment Conditions
Adjustment Procedures
8
NTSC colour saturation
adjustment
1. Input split colour bar signal.
INPUT 4
2. Select the following group and
subject.
Group: VIDEO1
Subject: N-COLOR
1. Select the VIDEO 1 menu
2. Check the fixed value of N-Color
Fixed value: 100
9
PAL colour saturation
adjustment
1. Input the PAL colour bar.
INPUT 4
2. Select the following group and
subject.
Group: VIDEO1
Subject: P-COLOR
1. Select the VIDEO 1 menu
2. Check the fixed value of P-Color
Fixed value: 94
10
SECAM colour saturation
adjustment
1. Input the SECAM colour bar.
INPUT 4
2. Select the following group and
subject.
Group: VIDEO1
Subject: S-COLOR
1. Select the VIDEO 1 menu
2. Check the fixed value of S-Color
Fixed value: 90
11
Check and readjustment of
white balance
1. Use the adjustment conditions in
the item 4.
Check that there is no deviation of white
balance with the monitor.
12
Colour-related operation
check
1. Input colour bars to INPUT 4.
2. Select the following group and
subject.
Group: Line
Subject: L1
1.Select L1 of the process mode LINE.
Operation check of Colour and Tint.
13
Video-related operation
check
1. Input monoscope to INPUT 4.
2. Select the following group and
subject.
Group: Line
Subject: L2
1.Select L2 of the process mode LINE.
Check of Picture, Bright, and Sharpness.
14
Operation check of RGB
1. Inputa RGB signal to INPUT 5.
2. Select the following group and
subject.
Group: Line
Subject: L4
1.Select L4 of the process mode LINE.
Check of Picture, Bright, Red, Blue, Clock,
Phase, H-POS, V-POS.
15
Off-timer performance
1. Set to no-signal state
2. Select the following group and
subject.
Group: Line
Subject: Off
1. Select OFF from the process mode LINE.
Make sure the off-timer starts with 5 minutes
onscreen and the set turns itself off after
about 6 seconds.
16
Delivery settings
1. Input the colour bar to INPUT 4.
2. Select the following group and
subject.
Group: SSS
Subject: S3 (Europe/Asia/Australia)
              S4 (North America)
1. Make the following settings.
17
Auto sync performance
checking
1. Feed the phase check pattern
signal.
1. In the VGA, SVGA and XGA modes,
make sure the Clock, Phase, H-Pos and V-
Pos settings can be automatically adjusted.
18
Inspection of HTPC720P
At INPUT 5 (DVI-1 connector)
1. Receive the colour bar signal.
2. Receive the grey scale signal.
3. Receive the SMPTERP-133 signal.
Check that there is no abnormality with the
screen.
19
Thermistor performance
checking
1. Heat the thermistor with a hair
dryer.
1. Make sure that the temperature is
indicated.
Electrical Adjustments
Version 1.3
Issue 04/2006
46
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
ADJUSTING THE PC BOARD
1. Initializing the EEPROM
1) Press SW2002 to enter the process mode.
2) Execute the S1 command on the SSS menu. (The S1 command initializes the PC board alone. Do
not execute the S2 command because otherwise the adjustment data other than the PC board will be
initialized.)
2. Adjustment of input signal level
2.1 Setting the oscilloscope
Set the oscilloscope range to DC 1V/div. and 5 ɵsec/div.
2.2 Connecting the PC interface
1) Connect the analogue output (signal generator) and the DVI-I connector (INPUT 5 of the projector)
with the cable (DSUB-DVI).
Set the INPUT SELECT of the projector to INPUT 5 (select the analogue RGB on the menu.)
2) Set the signal generator to the XGA mode (1024x768, 60 Hz, 32 tones). Adjust the output amplitude
to 700 mVp-p between the black and white levels (terminated with a 75-ohm impedance).
3) Turn on the power.
2.3 Adjustment of A/D (RGB)
1) Press SW2002 and enter the process mode.
2) Select AD-AUTO from the A/D (RGB) menu.
3) Press the ENTER key on the remote control. The AUTO adjustment is performed.
4) Exit the A/D (RGB) menu by pressing the UNDO key on the remote control.
2.4 Adjustment of A/D (COMP)
1) Select the A/D (COMP) menu.
2) Set G-BRIGHT to the numeric value of G-BRIGHT of A/D (RGB).
3) Adjust CB-OFFSET to 20.
4) Adjust CR-OFFSET to 20.
5) Exit the A/D (COMP) menu by pressing the UNDO key on the remote control.
2.5 Adjustment of color wheel index
1) Input the pattern for adjusting the color wheel index to INPUT5.
(Refer to "3. Color wheel index adjustment" in the "Adjustment method of each part" section.)
2) Select CW INDEX from the DLP menu.
3) Adjust so that the lamp gradation patterns of R, G and B become smooth without noise.
4) Exit the PLD menu by pressing the UNDO key on the remote control.
2.6 Select S5 from the SSS menu and press the ENTER key on the remote control.
Check that the OSD display of the set 5 appears.
Electrical Adjustments
Version 1.3
Issue 04/2006
47
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Adjusting Background adjustment method
Ι. Adjustment conditions
1) Adjustment item: Process mode: 
DLP menu 
GAMMA, 
R-GAIN, G-GAIN, B-GAIN
2) Input signal: Component video 75% white signal
1. With the component video 100% white signal, adjust the output to 0.7 
± 0.05 Vp-p
(excluding the synchronouspart.) (The sync signal is 0.3 Vp-p.)
2. Next drop the image signal output to 75%.
3. Input the signal to INPUT5 (DVI-I connector).
3) Target adjustment chromaticity
x = 0.290 
± 0.005
y = 0.311 
± 0.005 (Color temperature: 8500K, +6UV)
ΙΙ. Adjustment procedures
1) Select GAMMA from the DLP menu and set the value to “6”. (Initial value = 6)
2) Set R-GAIN, G-GAIN, B-GAIN to “96”. (Initial value = 95)
3) Background adjustment
1. Project on a 40-inch screen, and observe the chromaticity in the center with a
colour meter.
2. Fix G-GAIN to 95.
3. Adjust the x and y values to the target adjustment chromaticity with B-GAIN.
However, the adjusted value is up to 115 at maximum.
4. Adjust the x and y values to the target adjustment chromaticity with R-GAIN.
However, the adjusted value is up to 115 at maximum.
When the R-GAIN value is 115 and the x value cannot be adjusted,
1) Lower the B-GAIN and adjust to x = 0.290.
2) Lower the G-GAIN and adjust to y = 0.331.
5. Check that the middle gradation is not greatly deviated.
4) Exit the DLP menu by pressing the UNDO key on the remote control.
Electrical Adjustments
Version 1.3
Issue 04/2006
48
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Page of 56
Display

Click on the first or last page to see other XV-Z12000 service manuals if exist.