Size
539.77 KB
Type
PDF
Document
Service Manual
Brand
Device
Projector / Service manual part one
File
xv-c2e-sm2.pdf
Date

Sharp XV-C2E (serv.man2) Service Manual ▷ View online

XV-C2E
9
2. Removing the PWBs
2-1. Remove the four screws off the cooling fan.
2-2. Slide out the power unit, ballast unit, signal unit and main/sub units in their directions of arrow.  Disconnect
the connectors.
2-3. Remove the screws off the output unit and operation key unit.  Disconnect the connectors.
3. Removing the LCD module unit
3-1. Remove the screw off the panel cover.  Take out the panel cover.
3-2. Pull up the LCD module unit slowly out of position.
Sub Unit
(LL)
(LF)
2-3
Unit Holder
Top Cabinet
Operation Key Unit
Power Unit
Cooling Fan
(exhaust vent)
Signal Unit
Ballast Unit
Panel Cover
Output Unit
LCD
Module Unit
Main Unit
3-1
2-3
3-2
2-2
2-2
2-1
2-2
XV-C2E
10
4. Removing the optics mechanism assembly
4-1. Remove the two screws off the intake duct assembly.  Detach the intake duct assembly from the bottom
cabinet.
4-2. Remove the five screws off the optics mechanism assembly.  Detach the assembly from the bottom cabinet.
5. Removing the lamp
5-1. Remove the two lock screws off the lamp/cage
module unit.
5-2. Remove the three countersunk lock screws off
the upper and lower lamp cases.
5-3. Remove the lock screw and the nut off the lamp
terminal.
5-4. Release the lamp lock spring off the hook below
the lower lamp case.  Take out the lamp/mirror
assembly.
5-1
5-3
5-3
5-4
5-2
5-2
5-2
Lamp/cage module unit
Spring
Lower
lamp case
Upper
lamp case
Lamp/mirror
Ass'y
4-1
4-2
Optics Mecha Ass'y
Intake Duct
Ass'y
Bottom Cabinet Ass'y
XV-C2E
11
OPTICAL SYSTEM
PCAPH1048CESB
Lens cap
DLCPP0050DE01
LCD
PFiLW0173CEZZ
PFiLW0178CEZZ
PFiLW0161CEZZ
Incident deflection plate
Pre-deflection plate
UV/IR filter
PLNS-0124CEZZ
Projection lens
CLMPF0050DE02
Lamp/Mirror Ass'y
PFiLW0179CEZZ
Incident deflection plate
Optical unit
Cleaning the lenses and reflectors
1. Lens cleaner
• Cleaning liquid:
Change the mixture ratio of alcohol and ether depending on
ambient temperatures.  Make sure that the liquid evaporates
from the lens surface immediately after you rub it:  This is the
best ratio.  The more ether is used, the quicker the liquid
evaporates.
• Method:
Use well-washed bleached cotton cloth or cleaning paper
available on the market.  Damp the bleached cotton cloth with
the liquid, and hold the lens sandwiched in the cloth with your
thumb and the index finger.  Turn the lens and wipe the surface
clean from the center outward to collect dust.  Be careful not to
rub the coated surface too strong.
XV-C2E
12
Ë 
Controlling the total operating hours of the lamp
The following control is carried out when the lamp has been used for 1900 hours and 2000 hours.
1. After 1900-hour use
When the power is turned on, “LAMP” appears in the on-screen display for about 1 minute (flashing in yellow)
and the lamp LED indicator lights up in red.
When the 1900-hour point comes up during use of the unit, the “LAMP” display starts flashing in yellow on the
screen for 1 minute at the very 1900-hour point.
Now the lamp LED indicator changes from green to red.
2. After 2000-hour use
When the power is turned on, “LAMP” appears in the on-screen display for 5 minutes (flashing in red) and the
lamp LED indicator lights up in red. Five minutes thereafter, the power turns itself off and the unit is interrupted.
When the 2000-hour point comes up during use of the unit, the “LAMP” display starts flashing in red on the
screen for 5 minutes at the very 2000-hour point. Five minutes later, the power turns itself off and the unit is
interrupted. (The lamp LED indicator stays red since the 1900-hour point.)
If you try to turn on the power twice after the 2000-hour point, the unit remains off.
3. When the 2000-hour point comes up, take the following steps.
Replace the lamp with new one. While holding down both the "Volume 
"
" and "Select/Adjust 
'
" Keys on the
unit, turn on the main power switch (located on the back of the unit). The lamp operating hourmeter is now reset
to zero. Turn on the unit and make sure the time display shows “0000H”.
4. Displaying the total operating hours of the lamp
Change the STATUS3 data settings: PICTURE at 0, BRIGHT at MAX, COLOR at MIN, TINT at MIN, and
SHARPNESS at MAX. Hold down the SOUND DOWN and ENTER keys for longer than 2 seconds. By doing
this, the total operating hours will be displayed on the screen.
TIME
0000H
TOTAL TIME
0000H