Appendix
• If the temperature warning indicator illuminates, and the projector enters standby mode, follow the
possible solutions above and then wait until the projector has cooled down completely before plug-
ging in the power cord and turning the power back on. (At least 10 minutes.)
• If the power is turned off for a brief moment due to power outage or some other cause while using
the projector, and the power supply recovers immediately after that, the lamp indicator will illumi-
nate in red and the lamp may not be lit. In this case, unplug the power cord from the AC outlet,
replace the power cord in the AC outlet and then turn the power on again.
• The cooling fan keeps the internal temperature of the projector constant and this function is con-
trolled automatically. The sound of the cooling fan may change during operation because the fan
speed may change and this is not a malfunction.
• Do not unplug the power cord after the projector has entered standby mode and while the cooling
fan is running. The cooling fan runs for about 90 seconds.
Maintenance indicator
Problem
The internal
temperature is
abnormally
high.
The lamp does
not illuminate.
Time to change
the lamp.
The lamp does
not illuminate.
The power
indicator blinks
in red when the
projector is on.
Cause
• Blocked air intake
• Cooling fan
breakdown
• Internal circuit
failure
• Clogged air intake
• The lamp is shut
down abnormally.
• Remaining lamp life
becomes 5% or
less.
• Burnt-out lamp
• Lamp circuit failure
• The lamp unit cover
is open.
Possible Solution
• Relocate the projector to
an area with proper
ventilation. (see page 
8
)
• Take the projector to your
nearest Sharp Authorized
Projector Dealer or Service
Center (see page 
61
) for
repair.
• Disconnect the power cord
from the AC outlet, and
then connect it again.
• Carefully replace the lamp.
(See page 
51
.)
• Take the projector to your
nearest Sharp Authorized
Projector Dealer or Service
Center (see page 
61
) for
repair.
• Please exercise care when
replacing the lamp.
• Securely install the cover.
• If the power indicator blinks
in red even when the lamp
unit cover is securely
installed, contact your
nearest Sharp Authorized
Projector Dealer or Service
Center (see page 
61
) for
advice.
Abnormal
Red on
(Standby)
Red on
Red on
(Standby)
Red
blinks
Tempera-
ture
warning
indicator
Lamp
indicator
Power
indicator
Normal
Off
Green on
(Green
blinks
when the
lamp is
warming
up or
turning
off.)
Green on/
Red on
Green
blinks
(Cooling)
Info
50
Regarding the Lamp
Lamp
■ It is recommended that the lamp (sold separately) be replaced when the remaining lamp life becomes
5% or less, or when you notice a significant deterioration in the picture and color quality. The lamp life
(percentage) can be checked with the on-screen display. (see page 
44
)
■ Purchase a replacement lamp of type AN-XR20LP/AN-XR10LP from your place of purchase, nearest
Sharp Authorized Projector Dealer or Service Center.
Caution Concerning the Lamp
■ This projector utilizes a pressurized mercury lamp. A loud sound may indicate lamp failure. Lamp
failure can be attributed to numerous sources such as: excessive shock, improper cooling, surface
scratches or deterioration of the lamp due to a lapse of usage time.
The period of time up to failure largely varies depending on the individual lamp and/or the condition
and the frequency of use. It is important to note that failure can often result in the bulb cracking.
■ When the lamp replacement indicator and on-screen display icon are illuminated, it is recommended
that the lamp be replaced with a new one immediately, even if the lamp appears to be operating
normally.
■ Should the lamp break, there is also a possibility that glass particles may spread inside of the
projector. In such a case, it is recommended you contact your nearest Sharp Authorized Projector
Dealer or Service Center to assure safe operation.
■ Should the lamp break, the glass particles may spread inside the lamp cage or gas contained in the
lamp may be vented into the room from the exhaust vent. Because the gas in this lamp includes
mercury, ventilate the room well if the lamp breaks and avoid all exposure to the released gas. In case
of exposure to the gas, consult a doctor as soon as possible.
Replacing the Lamp
• Do not remove the lamp unit from the projector right after use. The lamp will be very hot and may
cause burn or injury.
■ Carefully change the lamp by following the instructions described in this section. * If you wish,
you may have the lamp replaced at your nearest Sharp Authorized Projector Dealer or Service
Center.
* If the new lamp does not light after replacement, take your projector to the nearest Sharp Authorized
Projector Dealer or Service Center for repair.
IMPORTANT NOTE TO U.S. CUSTOMERS:
The lamp included with this projector is backed by a 90-day parts and labor limited
warranty. All service of this projector under warranty, including lamp replacement,
must be obtained through a Sharp Authorized Projector Dealer or Service Center.
For the name of the nearest Sharp Authorized Projector Dealer or Service Center,
please call toll-free: 1-888-GO-SHARP (1-888-467-4277).
Hg LAMP CONTAINS MERCURY For State Lamp Disposal
Information
www.lamprecycle.org or 1-800-BE-SHARP
U.S.A. ONLY
51
Appendix
Removing and Installing the
Lamp Unit
• Make sure that you remove the lamp unit by
the handle. Do not touch the glass surface of
the lamp unit or the inside of the projector.
• To avoid injury to yourself and damage to the
lamp, be sure to carefully follow the steps
below.
• Do not loosen other screws except for the
lamp unit cover and lamp unit.
Press SSTANDBY/ON on the pro-
jector or 
eSTANDBY on the re-
mote control to put the projector
into standby mode.
• Wait until the cooling fan stops.
 Warning!
• Do not remove the lamp unit from the projec-
tor right after use. The lamp and parts around
the lamp will be very hot and may cause burns
or injury.
Disconnect the power cord.
• Unplug the power cord from the AC
socket.
• Leave the lamp until it has fully cooled
down (about 1 hour).
Remove the lamp unit cover.
• Turn the projector over. Loosen the user
service screw (1) that secures the lamp
unit cover. Remove the lamp unit cover
(2).
1
2
Lamp unit
AN-XR20LP
(for XR-20X/XR-20S)
AN-XR10LP
(for XR-10X/XR-10S)
Info
Optional
accessory
AC socket
User service screw
(for lamp unit cover)
1
2
3
STANDBY/ON button
52
Regarding the Lamp (Continued)
Remove the lamp unit.
• Loosen the securing screws from the
lamp unit. Hold the lamp unit by the
handle and pull it in the direction of the
arrow. At this time, keep the lamp unit
horizontal and do not tilt it.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Insert the new lamp unit.
• Press the lamp unit firmly into the lamp
unit compartment. Fasten the securing
screws.
Replace the lamp unit cover.
• Align the tab on the lamp unit cover
(1)and place it while pressing the tab
(2) to close it. Then tighten the user ser-
vice screw to secure the lamp unit cover.
4
5
6
Connect the power cord.
• Plug the power cord into the AC socket
of the projector.
Reset the lamp timer.
• While simultaneously holding down
UMENU/HELP, TENTER and R on the
projector, press SSTANDBY/ON on the
projector.
• “LAMP 0000H” is displayed, indicating
that the lamp timer is reset.
• Make sure to reset the lamp timer only when
replacing the lamp. If you reset the lamp timer
and continue to use the same lamp, this may
cause the lamp to become damaged or ex-
plode.
1
2
Info
AC socket
Securing screws
Handle
ENTER button
MENU/HELP
button
R button
• If the lamp unit and lamp unit cover are
not correctly installed, the power will not
turn on, even if the power cord is con-
nected to the projector.
Info