DOWNLOAD Sharp XG-PH70X (serv.man10) Service Manual ↓ Size: 1.15 MB | Pages: 15 in PDF or view online for FREE

Model
XG-PH70X (serv.man10)
Pages
15
Size
1.15 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
Projector
File
xg-ph70x-sm10.pdf
Date

Sharp XG-PH70X (serv.man10) User Manual / Operation Manual ▷ View online

XG-PH70X/XG-PH70X-N
1 – 9
[3] DIMENSIONS
Units: inches (mm)
16
5
/
32
(410)
4
11
/
32
(110.1)
3
3
/
4
(94.9)
7
1
/
16
(179)
7
1
/
16
(179)
3
23
/
64
(85)
9
39
/
64
(243.9)
13
5
/
8
(346)
5
47
/
64
(145.5)
45
/
64
(17.5)
7
3
/
32
(180)
3
55
/
64
(97.8)
3
23
/
32
(94.3)
31
/
64
(12.1)
18
35
/
64
(471)
M4
3
3
/
64
(77.27)
M4
M4
Side View
Side View
Top View
Rear View
Front View
Bottom View
XG-PH70X/XG-PH70X-N
1 – 10
[4] Maintenance Indicators
Power indicator
Lamp indicators 1, 2
Temperature warning indicator
Maintenance Indicators
Maintenance Indicators
The warning lights on the projector indicate problems inside the projector.
If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate
red, and the projector will enter the standby mode. After the projector has entered the standby
mode, follow the procedures given below.
About the temperature warning indicator
If the temperature inside the projector increases, due to blockage of the air vents, or the setting location,
"
" will illuminate in the lower left corner of the picture. If the temperature keeps on rising, the lamp will
turn off and the temperature warning indicator will blink, the cooling fan will run for a further 90 seconds, and
then the projector will enter the standby mode. After "
" appears, ensure you perform the measures
About the lamp indicator
"Change The Lamp. (LAMP 2)" is displayed when the remain-
ing life of the lamp 2 becomes 5% or less.
ı
When the remaining lamp life becomes 5% or less,"
" (yellow) and "Change The Lamp. (LAMP 1/2)"
will be displayed on the screen.
ı
When the percentage becomes 0%, it will change to "
"(red), the lamp will automatically turn off. At
this time, the lamp indicator will illuminate in red.
If you try to turn on the projector a fourth time without replacing the lamp, the lamp whose life is 0%
will not light up.
XG-PH70X/XG-PH70X-N
1 – 11
Maintenance indicator
Problem
Cause
Possible solution
Temperature
warning
indicator
Normal
Off
Red on
(Standby)
The internal
temperature is
abnormally high.
Abnormal
Blocked air intake
Relocate the projector to an area
with proper ventilation.
Cooling fan break-
down
Internal circuit failure
Clogged air intake
Clogged intake vent
cover
Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center for repair.
Clean the air vents and the intake
vent cover.
Lamp
indicators
1, 2
Red on
(Standby)
The lamp does
not illuminate.
Burnt-out lamp
Lamp circuit failure
Carefully replace the lamp.
Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center for repair.
Please exercise care when
replacing the lamp.
Red on
Time to change
the lamp.
Remaining lamp life
becomes 5% or less.
Green on
Green blinks
when the lamp
is warming up.
Info
If the temperature warning indicator blinks and the projector enters the standby mode, the temperature
warning indicator starts to illuminate. Check whether any of the ventilation holes are blocked
and then try turning the power back on. Wait until the projector has cooled down completely before plugging
in the power cord and turning the power back on. (At least 10 minutes.)
If the power is turned off for a brief moment due to power outage or some other cause while using the
projector, and the power supply recovers immediately after that, the lamp indicator will illuminate in red
and the lamp may not be lit. In this case, unplug the power cord from the AC outlet, replace the power
cord in the AC outlet and then turn the power on again.
The cooling fan keeps the internal temperature of the projector constant and this function is controlled
automatically. The sound of the cooling fan may change during operation because the fan speed may
change and this is not a malfunction.
The lamp does
not illuminate.
The lamp is shut
down abnormally.
Disconnect the power cord from
the AC outlet, and then connect it
again.
Power
indicator
Green on/
Red on
Red
blinks
The power
indicator blinks in
red when the
projector is on.
The intake vent
cover is open.
Securely install the cover.
If the power indicator blinks even
when the intake vent cover is
securely installed, contact your
nearest Sharp Authorized Projector
Dealer or Service Center for
advice.
XG-PH70X/XG-PH70X-N
1 – 12
[5] Regarding the Lamp
Lamp
It is recommended that the lamp units (optional: AN-PH7LP1 and AN-PH7LP2) be replaced when the
remaining lamp life becomes 5% or less, or when you notice a significant deterioration in the picture
and color quality. The lamp life (percentage) can be checked with the on-screen display.
Purchase a replacement lamp unit of type AN-PH7LP1 and AN-PH7LP2 from your place of purchase,
nearest Sharp Authorized Projector Dealer or Service Center.
IMPORTANT NOTE TO U.S. CUSTOMERS:
The lamp included with this projector is backed by a 90-day parts and labor limited warranty. All service
of this projector under warranty, including lamp replacement, must be obtained through a Sharp Autho-
rized Projector Dealer or Service Center. For the name of the nearest Sharp Authorized Projector Dealer
or Service Center, please call toll-free: 1-888-GO-SHARP (1-888-467-4277).
Hg LAMP CONTAINS MERCURY For State Lamp Disposal Information
www.lamprecycle.org or 1-800-BE-SHARP
Caution Concerning the Lamp
This projector utilizes a pressurized mercury lamp. A loud sound may indicate lamp failure. Lamp
failure can be attributed to numerous sources such as: excessive shock, improper cooling, surface
scratches or deterioration of the lamp due to a lapse of usage time.
The period of time up to failure largely varies depending on the individual lamp and/or the condition
and the frequency of use. It is important to note that failure can often result in the bulb cracking.
When the lamp indicator and on-screen display icon are illuminated, it is recommended that the
lamp be replaced with a new one immediately, even if the lamp appears to be operating normally.
Should the lamp break, the glass particles may spread inside the lamp cage or gas contained in the
lamp may be vented into the room from the exhaust vent. Because the gas in this lamp includes
mercury, ventilate the room well if the lamp breaks and avoid all exposure to the released gas. In
case of exposure to the gas, consult a doctor as soon as possible.
Should the lamp break, there is also a possibility that glass particles may spread inside of the
projector. In such a case, it is recommended you contact your nearest Sharp Authorized Projector
Dealer or Service Center to assure safe operation.
Replacing the Lamp
Caution
Do not remove the lamp unit from the projector right after use. The lamp will be very hot and may cause burn
or injury.
Wait at least one hour after the power cord is disconnected to allow the surface of the lamp unit to fully cool
before removing the lamp unit.
ı Carefully change the lamp by following the instructions described in this section. *If you wish, you
may have the lamp replaced at your nearest Sharp Authorized Projector Dealer or Service Center.
* If the new lamp does not illuminate after replacement, take your projector to the nearest Sharp Authorized
Projector Dealer or Service Center for repair.
Regarding the Lamp
U.S.A. ONLY
Page of 15
Display

Click on the first or last page to see other XG-PH70X (serv.man10) service manuals if exist.