13. Removing the Filter Unit
13-1. Disconnect all the connectors from the filter unit. Remove the four screws from the filter unit and then take it
out.
14. Removing the IR(Rear) Unit
14-1 Disconnect all the connectors from the power unit. Remove the six screws from the Plate and then take out
the Plate.
14-2. Remove the screw from the IR(Rear) unit and detach the IR(Rear) unit.
13-1
Filter Unit
Chassis
PR1
PR2
PR3
PR1
PR2
PR3
IR(Rear) Unit
14-1
14-2
Power Unit
Plate
Chassis
30
XG-PH50X
XG-PH50X-NL
XG-PH50X-NL
15. Removing the Power Unit and Audio Unit
15-1. Remove the four screws from the power unit.
15-2. Detach the power air guide from the power channel upper.
15-3. Remove the four screws from the power channel down and then disconnect the two power connector PR.
15-4. Remove the four screws from the power unit and then take out the power unit.
15-5. Remove the four screws from the holders and then disconnect the signal connectors SG.
15-6 Remove the four screws from the audio unit and then take out the audio unit.
15-2. Detach the power air guide from the power channel upper.
15-3. Remove the four screws from the power channel down and then disconnect the two power connector PR.
15-4. Remove the four screws from the power unit and then take out the power unit.
15-5. Remove the four screws from the holders and then disconnect the signal connectors SG.
15-6 Remove the four screws from the audio unit and then take out the audio unit.
Power Unit
15-1
15-2
15-3
15-4
15-5
15-6
Power Channel upper
Audio Unit
Power Air Guide
Holder
Holder
Ballast Unit
Power Unit
Power Unit Insulator
Power Channel Down
SG
Chassis
31
XG-PH50X
XG-PH50X-NL
XG-PH50X-NL
RESETTING THE TOTAL LAMP TIMER
●
Resetting the total lamp timer
When replacing the lamp, reset the total lamp timer in the procedure below.
When replacing the lamp, reset the total lamp timer in the procedure below.
Lamp
■
It is recommended that the lamp units (optional: AN-PH50LP1 and AN-PH50LP2) be replaced when the remaining
lamp life becomes 5% or less, or when you notice a significant deterioration in the picture and color quality. The
lamp life (percentage) can be checked with the on-screen display.
lamp life becomes 5% or less, or when you notice a significant deterioration in the picture and color quality. The
lamp life (percentage) can be checked with the on-screen display.
■
Purchase a replacement lamp unit of type AN-PH50LP1 and AN-PH50LP2 from your place of purchase, nearest
Sharp Authorized Projector Dealer or Service Center.