DOWNLOAD Sharp XG-C68X Service Manual ↓ Size: 1.09 MB | Pages: 60 in PDF or view online for FREE

Model
XG-C68X
Pages
60
Size
1.09 MB
Type
PDF
Document
Handy Guide
Brand
Device
Projector / Version 1.1
File
xg-c68x.pdf
Date

Sharp XG-C68X Handy Guide ▷ View online

Electrical Adjustments
Version 1.1
Issue 04/2006
49
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Group
Sub Group
Subject
CMS-HUE
CMS-HUE-R
CMS-HUE-Y
CMS-HUE-G
CMS-HUE-C
CMS-HUE-B
CMS-HUE-M
CMS-SAT
CMS-SAT-R
CMS-SAT-Y
CMS-SAT-G
CMS-SAT-C
CMS-SAT-B
CMS-SAT-M
Adjust CVIC (cont.)
CVIC
CMS-VAL
CMS-VAL-R
CMS-VAL-Y
CMS-VAL-G
CMS-VAL-C
CMS-VAL-B
CMS-VAL-M
DEGAMMA
Adjust Digital Convergence
CONVER
CC
R-CNV-H
G-CNV-H
B-CNV-H
R-CNV-V
G-CNV-V
B-CNV-V
Version Check etc
SPECIAL
IPL
IPL2
E2PROM
ADR RD/WR
Adjustment of the Mirrors
Version 1.1
Issue 04/2006
50
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Adjusting the mirrors
This adjustment is needed when any of the optical parts of the optical mechanism has been
replaced.
1. Disconnect the flat cables from all the LCD panels.
2. Light up the lamp.
3. Project a white-light image and check to see if there is any colour tint in any direction. If
any, use the M2, M4 and M5 adjusting levers.
4. Loosen the adjusting lever lock screws, make adjustments, and tighten up the lock screws.
Adjustment of the Mirrors
Version 1.1
Issue 04/2006
51
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Adjustment of the Mirrors
Version 1.1
Issue 04/2006
52
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Correcting colour irregularities on white-only screen when replacing the
lamp
If colour irregularities are found at the right and left on a white-only screen after replacing the
lamp, it is necessary to readjust the optical axis of the new lamp. Take the following steps.
1. Open the lamp cover and loosen the screws A and B at the bottom of the lamp.
2. Using a screwdriver or the like, move the U-shaped groove at the window D in the arrow
direction.
3. Temporarily fix the screws A and B, close the lamp cover, and check the white-only screen
again for colour irregularities.
4. Repeat the above steps 1 and 2 until there will be no colour irregularities. Now tighten up
the screws A and B.
5. Finally secure the lamp cover back in position.
Page of 60