28
XG-C55X
Creation of correction value by straight-line
correction coefficient:
No (not checked)
Number of image captures (when adjustment,
measurement):
2 times
Number of image captures (when teaching):
4 times
(2) Teaching
Basically only one time measurement is necessary for each model for teaching, however when the optical
characteristics, etc. of the set are greatly changed, set the conditions again and measurement is neces-
sary again according to the changes.
Measurement method of the correction coefficient
(1) Determines the standard set of C55. 1 unit (n units)
(2) Set settings are RGB mode INPUT 1.
(3) Execute teaching in the following condition setting in that standard set.
Condition setting
Model name:
Newly input the model name and optical characteris-
tics Var.
Resolution:
(Not related)
Correction value X direction:
29
Correction value Y direction:
22
Correction bits number:
8
Minimum adjustment value:
0
Center adjustment value:
36
Maximum adjustment value:
73
Teaching number:
5
Teaching interval:
18
Brightness change direction by adjustment value: Brightness up with adjustment value + (checked)
Adjusting points:
3-dimension (checked)
Gradation 4 (checked)
Gradation 5 (checked)
Gradation 6 (checked)
Do not check the gradations other than these.
Adjusting point (Test pattern display level)
Gradation 7:
91%
Gradation 6:
78%
Gradation 5:
65%
Gradation 4:
52%
Gradation 3:
40%
Gradation 2:
25%
Gradation 1:
13%
Gradation 0:
0%
Adjustment color:
Adjustment with WHITE (checked)
(3) Color irregularity correction
Conditions setup
Correction procedure settings
Gradation 7:
2. Lower-gradation correction value to be used.
Gradation 6:
0. Correction with correction coefficient.
Gradation 5:
0. Correction with correction coefficient.
Gradation 4:
0. Correction with correction coefficient.
Gradation 3:
1. Upper-gradation correction value to be used.
29
XG-C55X
21
Checking and
readjustment of
white balance
1. The adjusting conditions for each
item are as follows:
For RGB input, see Item 7.
For video input, see Item 14.
For COMPO input, see Item 17.
No.
Adjustment Items
Adjustment Conditions
Adjustment Procedures
1. Make sure the white balance is as
specified on the standard monitor.
For readjustment, proceed in the or-
der of RGB input, video input and
COMPO input.
22
Checking color-
related perfor-
mance
1. Receive the color bar signal.
1. Select L1 in the process mode.
Check the performance of Color and
Tint.
23
Checking of
picture-related
performance
1. Receive the monoscope pattern sig-
nal.
1. Select L2 in the process mode.
Check Picture, Brightness and Sharp-
ness.
24
Checking of RGB
performance
1. Receive the RGB signal.
1. Select L4 on the process mode.
Check Picture, Brightness, Red, Blue,
Clock, Phase, H-POS and V-POS.
25
Checking of off-
timer performance
1. Select OFF in the process mode.
Make sure that the off-timer starts
with 5-minute display, counts down
1 minute for 1 second, and turns off
when 0 minute is displayed.
26
Checking of
thermistor perfor-
mance
1. Heat the thermistor with a hair dryer.
1. Make sure the temperature is dis-
played.
27
Automatic sync
operation
1. Receive the phase checking pattern
signal.
1. Make sure that Clock, Phase, H-POS
and V-POS can be automatically
adjusted in the VGA/S-VGA/XGA
mode.
29
Factory settings
1. Make the following settings.
Process
Remote
Destination
adjustment
controller
settings
North-
      S4
Factory
American
Setting 4
Other
      S3
Factory
Setting 3
28
Vertical line level
check
1. Receive the RGB signal. 10-step
gray-scale
1. Compare with the vertical line bound-
ary sample, and it must be at the
boundary sample or less. In case that
it is bad, adjust the PSIG-L of the
item 3.
However, it must be within the range
of 190 - 200.
Gradation 2:
1. Upper-gradation correction value to be used.
Gradation 1:
1. Upper-gradation correction value to be used.
Gradation 0:
1. Upper-gradation correction value to be used.
For the model in question, select the name entered in (2) to start the color irregularity correction. If the
set has its optical characteristics rather different from the standard ones or if the set has some color
irregularity lines missing, do the teaching for that set in particular. Use its specified correction coeffi-
cients in making the adjustment.
30
XG-C55X
How to Adjust the PC I/F unit
1. Initialization of EEPROM
1) Press SW2601 to enter the process mode.
2) Execute S1 on the SSS menu. (By S1, the PC board alone is initialized. Do not execute S2, or all the
adjustment data, except for the PC I/F unit, is initialized.)
3) Make sure that the program version "VER. XXX" on the SPECIAL menu is the latest one.
2. Level adjustments
2-1. Setting the oscilloscope
Set the oscilloscope's range to DC1V/div and 5µ S/div.
2-2. Connecting the PC interface
1) Connect the specified cable between ANALOG OUTPUT (on the signal generator) and DSUB connector
(INPUT1 on the projector).
2) Set the projector's input selector to INPUT1.
3) Set the signal generator to XGA mode (1024x768, 60Hz, 32-step gradation). Also adjust the output
amplitude (between black and white) to 700 mVp-p (terminated with a 75-ohm impedance).
4) Turn on the power.
2-3. Adjusting items
1) Adjustment of RGB drive/gain
(1) Feed the window pattern signal that has 100% and 0% signals.
(2) Select AUTO among the A/D items in the process mode and make the adjustments.
31
XG-C55X
Group
Sub Group
Subject
Adjust PC Image
A/D
R-BRIGHT
G-BRIGHT
B-BRIGHT
R-D
B-D
G-D
AD-AUTO
Adjust RGB Image
OUTPUT1
R1-BLK
R1-GAIN
G1-BLK
G1-GAIN
B1-BLK
B1-GAIN
S-R1-BLK
S-R1-GAIN
S-G1-BLK
S-G1-GAIN
S-B1-BLK
S-B1-GAIN
Adjust Panel Drive
OUTPUT2
PSIG-H
PSIG-L
LC-SW
LC-R-SIG
LC-G-SIG
LC-B-SIG
LC-R-LV
LC-G-LV
LC-B-LV
Adjust Commn Voltage
OUTPUT3
RC
GC
BC
RCK-PHASE
GCK-PHASE
BCK-PHASE
ENBX-WIDTH
ENBXR-PH
ENBXG-PH
ENBXB-PH
DGC-SW
DGCJ-R
DGCJ-G
DGCJ-B
» Adjustment mode process menu
» Entering the adjustment process mode
 
  There are following two methods.
   
»
 Press the SW2601 on the Output unit.
  
 »
 Press the follwing keys in this order.
      ON→Adj up→Adj down→Adj up→Adj down→ENTER→ENTER→MENU
Page of 10
Display