Sharp XG-C50XE (serv.man31) User Manual / Operation Manual ▷ View online

-84
Maintenance Indicators
Info
• If the temperature warning indicator illuminates, and the power turns off, follow the above possible solutions
and then wait until the projector has cooled down completely before plugging in the power cord and  turning
the power back on. (At least 5 minutes.)
• If the power is turned off and then turned on again, as during a brief test, the lamp replacement indicator may
be triggered, preventing the power from going on. Should this occur, take the power cord out of the wall outlet
and plug it back in again.
• If you want to clean the air vents during projector operation, be sure to first press 
 and after the power has
turned off and the cooling fan has stopped, then clean the vents.
• Do not unplug the power cord after the power has been turned off and while the cooling fan is running. The
cooling fan runs for about 90 seconds.
Appendix
-85
Lamp
■ It is recommended that the lamp (sold separately) be replaced when the remaining lamp life be-
comes 6% or less, or when you notice a significant deterioration in the picture and color quality. The
lamp life (percentage) can be checked with the on-screen display. See page 
70
.
■ For lamp replacement, please consult your nearest Sharp Authorized Projector Dealer or Service
Center.
IMPORTANT NOTE TO U.S. CUSTOMERS:
The lamp included with this projector is backed by a 90-day parts and labor limited warranty. All service
of this projector under warranty, including lamp replacement, must be obtained through a Sharp Autho-
rized Projector Dealer or Service Center. For the name of the nearest Sharp Authorized Projector Dealer
or Service Center, please call toll-free: 1-888-GO-SHARP (1-888-467-4277).
U.S.A. ONLY
Caution Concerning the Lamp
■ This projector utilizes a pressurized mercury lamp. A loud sound may indicate lamp failure. Lamp
failure can be attributed to numerous sources such as: excessive shock, improper cooling, surface
scratches or deterioration of the lamp due to a lapse of usage time. The period of time up to failure
largely varies depending on the individual lamp and/or the condition and the frequency of use. It is
important to note that failure can often result in the bulb cracking.
■ When the lamp replacement indicator and on-screen display icon are illuminated or flash, it is rec-
ommended that the lamp be replaced with a new one immediately, even if the lamp appears to be
operating normally.
■ Should the lamp break, the glass particles may spread inside the lamp cage or gas contained in the
lamp may be vented into the room from the exhaust vent. Because the gas in this lamp includes
mercury, ventilate the room well if the lamp breaks and avoid all exposure to the released gas. In
case of exposure to the gas, consult with a doctor as soon as possible.
■ Should the lamp break, there is also a possibility that glass particles may spread inside of the
projector. In such a case, it is recommended you contact your nearest Sharp Authorized Projector
Dealer or Service Center to remove the damaged lamp and assure safe operation.
Replacing the Lamp
Caution
• Do not remove the lamp unit immediately after operation of the projector. The lamp will be hot and touching
it can lead to burn or injury.
• Wait at least one hour after the power cord is disconnected to allow the surface of the lamp unit to fully cool
before removing the lamp unit.
■ If the new lamp does not light after replacement, take your projector to the nearest Sharp Autho-
rized Projector Dealer or Service Center for repair. Purchase a replacement lamp unit of type BQC-
XGC50X//1 from your nearest Sharp Authorized Projector Dealer or Service Center. Then carefully
change the lamp by following the instructions described in this section. If you wish, you may have
the lamp replaced at your nearest Sharp Authorized Projector Dealer or Service Center.
Regarding the Lamp
Power (OFF) button
Lamp
unit
BQC-XGC50X//1
User service screw
Removing and Install-
ing the Lamp Unit
Info
• Be sure to remove the lamp unit by the
handle. Be sure not to touch the glass
surface of the lamp unit or the inside of
the projector.
• To avoid injury to yourself and damage
to the lamp, be sure to carefully follow
the steps below.
• Do not loosen other screws except for the
lamp unit cover and lamp unit.
(Only the silver screws are loosened).
• Please refer to the installation manual
included with the lamp unit.
1
Press 
  on the projector to
turn off the power.
• Wait until the cooling fan stops.
Warning!
• Do not remove the lamp unit from the
projector right after use. The lamp will
be very hot and may cause burn or
injury.
2
Disconnect the power cord.
• Unplug the power cord from the AC
socket.
• Leave the lamp until it has fully cooled
down (about 1 hour).
3
Change the air filter.
• Change the air filter whenever you in-
stall the lamp unit (see pages 
81
 and
82
).
4
Remove the lamp unit cover.
• Loosen the user service screw that
secures the lamp unit cover. Then
open the cover in the direction of the
arrow.
AC socket
-86
Regarding the Lamp
Appendix
-87
Securing
screw
AC socket
INPUT button
ENTER button
User service screw
UNDO buttom
Power (ON)
button
5
Remove the lamp unit.
• Loosen the securing screws from the
lamp unit. Hold the lamp unit by the
handle and pull it in the direction of
the arrow.
6
Insert the new lamp unit.
• Press the lamp unit firmly into the lamp
unit compartment. Fasten the secur-
ing screws.
7
Attach the lamp unit cover.
• Insert the tab of the lamp unit cover
into the opening, and press the cover
until it clicks in place.
Info
• If the lamp unit and lamp cover are not
correctly installed, the power will not turn
on, even if the power cord is connected
to the projector.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
1
Connect the power cord.
• Plug the power cord into the AC socket
of the projector.
2
  Reset the lamp timer.
• While pressing simultaneously 
and 
 on the projector, press 
ON
on the projector.
• “LAMP 100%” is displayed, indicating
that the lamp timer is reset.
Info
• Make sure to reset the lamp timer only
when replacing the lamp. If you reset the
lamp timer and continue to use the same
lamp, this may cause the lamp to become
damaged or explode.
Page of 24