41
XG-C50X
TROUBLE SHOOTING TABLE for PC I/F UNIT (Continued)
No
Yes
Yes
Yes
Checking of R, G and B Signals
Is the signal type set to RGB?
Set the signal type to RGB.
No
No
Set the process mode.
Select R, G and B individually on 
the pattern menu.
Go to "Checking of GA4 and Its 
Periphery".
For checking the input signal, set 
the signal generator to gradation 
signal.
Measure the signals at TL8169, 
TL8170 and TL8180 on the 
oscilloscope. (MSB bit after A/D 
conversion)
Are there the specified signals at 
TL8169, TL8170 and TL8180?
Does the signal come to C8062, 
C8070 and C8078?
Go to "Confirmation of Video Input".
IC8013 or its periphery is defective.
IC8025 or its periphery is defective.
42
XG-C50X
TROUBLE SHOOTING TABLE for PC I/F UNIT (Continued)
No
No
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
Checking of GA4 and Its Periphery
Select R, G and B individually on 
the pattern menu in the process 
mode.
Is picture outputted appropriately 
in R, G and B?
Checking of GA4 and its periphery 
ends.
Measure the signals at pins (54), 
(66) and (78) of SC8001 on the 
oscilloscope. These signals are 
MSB of B/G/R/.
Do the oscilloscope-measured 
signals match with those selected 
on the pattern menu?
The OUTPUT PWB is defective.
Does the clock signal come to pins 
(40) and (42) of SC8001?
Is there the clock (37.5 MHz) 
signal at TL8114?
IC8029 is defective.
Is there the clock (37.5 MHz) 
signal at FL8110?
X8005 is defective.
IC8025 is defective.
Measure the signals at TL8106, 
TL8107, TL8108, TL8110 and 
TL8111 on the oscilloscope.
Do the oscilloscope-measured 
signals match with those selected 
on the pattern menu?
IC8025 is defective.
IC8029 is defective.
43
XG-C50X
TROUBLE SHOOTING TABLE for PC I/F UNIT (Continued)
Yes
No
Yes
Yes
No
No
No
4
4
Checking of Component Input 
(except 480I)
Feed the component signal to 
INPUT1.
Select INPUT1 using the set's key 
or the remote controller.
Does the picture appear?
Go to "Checking of SOG Circuit".
Are the colors normal?
Is the signal type set at 
component?
Set the signal type to component.
Is the contour of picture clear?
IC8013 or IC8025 is defective.
The component is normal. End.
Carry out the process adjustment.
44
XG-C50X
Yes
Yes
No
No
Checking of SOG Circuit
Measure the signal at pin (2) of 
IC8365 on the oscilloscope.
Is the composite sync signal 
reproduced in correct timing?
The SOG circuit is normal. End.
Measure the land of C8070 on the 
oscilloscope.
Is there the Y signal including sync 
signal?
Go to "Confirmation of Input Signal 
Setting".
The SOG sync separation circuit 
(INPUT PWB) is defective.