DOWNLOAD Sharp XG-C40XE (serv.man3) Service Manual ↓ Size: 6.34 MB | Pages: 33 in PDF or view online for FREE

Model
XG-C40XE (serv.man3)
Pages
33
Size
6.34 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / Service manual section 2 - Additional and amended information
File
xg-c40xe-sm3.pdf
Date

Sharp XG-C40XE (serv.man3) Service Manual ▷ View online

8
XG-C40XU
(
1
)
XG-C40XE
(
1
)
No.
Adjusting point
Adjusting conditions
Adjusting procedure
26
Colour system
performance
check
1. Receive the colour bar sig-
nal.
»
In the process mode and select L1. Check the col-
our and tint.
27
Video system
performance
check
1. Receive the monoscope pat-
tern signal.
»
In the process mode and select L2. Check the pic-
ture, brightness and sharpness.
28
Audio system
performance
check
»
In the process mode nad select L3. Check the bass,
treble.
29
RGB
performance
check
1. Receive the RGB signal.
»
In the process mode and select L4. Check the pic-
ture, brightness, red, blue, clock, phase, horizontal
position, and vertical position.
30
Off-timer
performance
check
»
In the process mode and select OFF. Make sure that
the off-timer starts with “5” (minutes), counts down each
minute in 1 second, and turns off the set at “0”.
31
Thermistor
performance
check
1. Heat the thermistor using a
dryer.
»
Make sure the “TEMP” is displayed.
32
Automatic
synchronization
1. Receive the PHASE check
pattern signal.
»
Call the VGA/SVGA/XGA/SXGA mode and make
sure that the clock, phase, horizontal and vertical
positions can be automatically adjusted.
33
Keystone
correction
performance
check
»
Make sure the keystone correction functions well.
34
Factory settings
»
Make the following settings.
S3
“Factory setting 3”(XG-C40XE1)
S4
“Factory setting 4”(XG-C40XU1)
Process
adjustment
Remote controller setting
9
XG-C40XU
(
1
)
XG-C40XE
(
1
)
Ref.Nr.
Beschreibung
Bestehend
Neu
Bemerkung
   LCD PANELS
XG-C40XU(1) 
/
 XG-C40XE(1)
LCD Module Unit Red
RLCDP141CEZZ
RLCDPA004WJZZ
LCD Module Unit Green
RLCDP142CEZZ
RLCDPA005WJZZ
LCD Module Unit Blue
RLCDP143CEZZ
RLCDPA006WJZZ
   PWB ASSEMBLIES
XG-C40XU(1)
Signal Unit
DUNTKA211DE11
DUNTKB116DE04
Sechs Teile verändert
PC Terminal Unit
DUNTKA212DE11
DUNTKB117DE04
Keine Teile verändert
S-Out/Regulater Unit
DUNTKA693FE01
DUNTKA693FE04
Keine Teile verändert
Output Unit
DUNTKA694FE01
DUNTKB181FE01
Video Unit
DUNTK9769DE24
AC Inlet Unit
RUNTK0677CEZZ
Power Unit
RDENC0334CEZZ
Ballast Unit
RDENC0333CEZZ
PC I/F Unit
CPCi-0047CE15
CPCi-0047CE18
Keine Teile verändert
   PWB ASSEMBLIES
    XG-C40XE(1)
Signal Unit
DUNTKB116DE02
DUNTKB116DE05
Keine Teile verändert
PC Terminal Unit
DUNTKB117DE02
DUNTKB117DE05
Keine Teile verändert
S-Out/Regulater Unit
DUNTKA693FE02
DUNTKA693FE05
Keine Teile verändert
Output Unit
DUNTKA694FE02
DUNTKB181FE02
Video Unit
DUNTK9769DE25
AC Inlet Unit
DUNTK0677CEZZ
Power Unit
RDENC0334CEZZ
Ballast Unit
RDENC0333CEZZ
PC I/F Unit
CPCi-0047CE16
CPCi-0047CE19
Keine Teile verändert
   SIGNAL UNIT
XG-C40XU(1)
   C886
Capacitor 22 16V EL.
VCEAPF1CW226M
   C887
Capacitor 10 16V EL.
VCEAPF1CW106M
   R1010
Resistor 0 1/16W M-Ox.
VRS-CY1JF000J
   R1011
Resistor 0 1/16W M-Ox.
VRS-CY1JF000J
   R1013
Resistor 0 1/16W M-Ox.
VRS-CY1JF000J
   R1814
Resistor 0 1/16W M-Ox.
VRS-CY1JF000J
   OUTPUT UNIT
XG-C40XU(1) 
/
 XG-C40XE(1)
     Beziehen Sie sich auf die Teilliste
   CABINET AND MECHANICAL PARTS
XG-C40XU(1) 
/
 XG-C40XE(1)
   3-2
Bottom Cabinet Ass
y
DBDYU1140CEK1
DBDYU1140CEK2
XG-C40XU1
   3-2
Bottom Cabinet Ass
y
DBDYU1141CEK1
DBDYU1141CEK3
XG-C40XE1
LISTE VON VERÄNDERTEN TEILEN
10
XG-C40XU
(
1
)
XG-C40XE
(
1
)
Ref.Nr.
Beschreibung
Bestehend
Neu
Bemerkung
   OPTICS MECHANISM PARTS
XG-C40XU(1) 
/
 XG-C40XE(1)
   6-37
LCD Module Unit Red
RLCDP0141CEZZ
RLCDPA004WJZZ
   6-38
LCD Module Unit Green
RLCDP0142CEZZ
RLCDPA005WJZZ
   6-39
LCD Module Unit Blue
RLCDP0143CEZZ
RLCDPA006WJZZ
   6-47
Screw M2.6-8, x12
XASSF26P06000
XASSF26P08000
   6-83
Emergent Polarizer B
PFiLW0295CEZZ
PFiLW0300CEZZ
   6-91
Flyeye Lens Aperture
PSLDP3078CEFW
Streichen
   SUPPLIED ACCESSORIES
XG-C40XU(1) 
/
 XG-C40XE(1)
CD-ROM
UDSKA0053CEN1
UDSKA0059CEN1
CD-ROM
UDSKA0057CEN1
UDSKA0059CEN1
   SERVICE JIGS
XG-C40XU(1)    XG-C40XE(1)
Extension Cable 20-pin
QCNW-5058CEZZ
QCNW-5419CEZZ
Extension Cable 32-pin
QCNW-5688CEZZ
QCNW-4852CEZZ
11
XG-C40XU
(
1
)
XG-C40XE
(
1
)
ELEKTRISCHE EINSTELLUNG
Einen Signalgenerator, PC oder Macintosh-Computer am Projektor anschließen, um die in den
Einstellbedingungen spezifizierten Signale zuzuführen.
Nr.
Einstellposition
Einstellbedingung
Einstellverfahren
1
EEPROM-
Initialisierung
1. Den Netzschalter
einschalten und das Gerät
für ca. 15 Minuten
vorwärmen lassen.
(Sicherstellen, daß die
Kontrollampe aufleuchtet.)
»
Folgende Einstellungen vornehmen:
SW5101 drücken, um den Verarbeitungsmodus
abzurufen, und um S2 im SSS-Menü auszuführen.
Das System ist nun initialisiert (PC-Platine nicht
miteingeschlossen). S1 darf nicht ausgeführt
werden, da die PC-Platine sonst initialisiert wird.
Um die Platine einzustellen, die Vorschriften in
"Einstellung der Platine" folgen.
2
3,3 V-
Stromversorgungs-
Einstellung
1. Den Netzschalter
einschalten.
2. Den Digitalvoltmeter an
TP1446 anschließen.
»
R1649 einstellen, bis der Voltmeter 3,43 V 
±
0.03
Vs-s zeigt.
3
2,5 V-
Stromversorgungs-
Einstellung
1. Den Netzschalter
einschalten.
2. Den Digitalvoltmeter an
TP1447 anschließen.
»
R1652 einstellen, bis der Voltmeter 2,60 V 
±
0.05
Vs-s zeigt.
4
R-Antrieb
1. Das Rotsignal (100%)
zuführen und die folgende
Wahl treffen.
Gruppe : Analog/Digital
Gegenstand: R-D
»
Die Regelschalter oder die Tasten auf der
Fernbedienung betätigen und die Daten so
einstellen, daß das Signal "bitlos" (Störung) wird.
5
B-Antrieb
1. Das Blausignal (100%)
zuführen und die folgende
Wahl treffen.
Gruppe : Analog/Digital
Gegenstand : B-D
»
UDie Regelschalter oder die Tasten auf der
Fernbedienung betätigen und die Daten so
einstellen, daß das Signal "bitlos" (Störung) wird.
6
G-Antrieb
1. Das Grünsignal (100%)
zuführen und die folgende
Wahl treffen.
Gruppe : Analog/Digital
Gegenstand : G-D
»
Die Regelschalter oder die Tasten auf der
Fernbedienung betätigen und die Daten so
einstellen, daß das Signal "bitlos" (Störung) wird.
7
Schwarzpegel-
Signalamplitude
für RGB 1-
System
(ungeradzahlig)
1. Die folgende Wahl treffen.
Gruppe : OUTPUT 1
Gegenstand : G1-BLK
G1-GAIN
Für Rot sind die
Gegenstände R1-BLK und
R1-GAIN zu wählen.
Für Blau sind die
Gegenstände B1-BLK und
B1-GAIN zu wählen.
2. Das Oszilloskop
anschließen an
TP1101 für Rot.
TP1201 für Grün.
TP1301 für Blau.
»
Den Gegenstand G1-GAIN wählen und den
Schwarz-Spitzenpegel auf 3,6 
±
0,1 Vs-s
Gleichspannung einstellen. Hierfür die
Regelschalter oder die Tasten auf der
Fernbedienung betätigen.
»
Danach den Gegenstand G1-BLK wählen und die
Weiß-zu-Weiß Pegeldifferenz auf 2,5 
±
0,1 V-
Gleichstrom einstellen.
3,6Vs-s
(F r Rot und Blau auf 
2,5 V einstellen.)
(F r Gr n und Blau
auf 3,6 Vs-s einstellen.)
2.5V
»
Die Signalamplitude auf 2,5 
±
0,1 V-Gleichstrom
und die Weiß-zu-Weiß Pegeldifferenz auf
3,6 
±
0,1Vs-s  für das Rot und Blau einstellen.
Page of 33