DOWNLOAD Sharp XG-C40XE (serv.man15) Service Manual ↓ Size: 15.33 MB | Pages: 115 in PDF or view online for FREE

Model
XG-C40XE (serv.man15)
Pages
115
Size
15.33 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / Service Manual Complete
File
xg-c40xe-sm15.pdf
Date

Sharp XG-C40XE (serv.man15) Service Manual ▷ View online

95
94
XG-C40XU/XE
XG-C40XU/XE
8
7
9
6
5
4
3
2
1
A
C
D
E
F
G
H
17
16
19
18
15
14
13
12
11
10
BLOCK DIAGRAM / BLOCKSCHALTBILD
97
96
XG-C40XU/XE
XG-C40XU/XE
8
7
9
6
5
4
3
2
1
A
C
D
E
F
G
H
17
16
19
18
15
14
13
12
11
10
OVERALL WIRING DIAGRAM / GESAMTSCHALTPLAN
98
8
7
10
9
6
5
4
3
2
1
A
C
D
E
F
G
H
XG-C40XU/XE
DESCRIPTION OF SCHEMATIC
DIAGRAM
VOLTAGE MEASUREMENT CONDITION:
1. Voltages at test points are measured at the supply
voltage of AC 230V. Signals are fed by a colour bar
signal generator for servicing purpose and the above
voltages are measured with a 20k ohm/V tester.
WAVEFORM MEASUREMENT CONDI-
TION:
1. Waveforms at test points are observed at the supply
voltage of AC 230V. Signals are fed by a colour bar
signal generator for servicing purpose.
INDICATION OF RESISTOR & CAPACI-
TOR:
RESISTOR
1. The unit of resistance “
” is omitted.
(K=k
=1000 
, M=M
).
2. All resistors are 
±
 5%, unless otherwise noted.
(J= 
±
 5%, F= 
±
 1%, D= 
±
 0.5%)
3. All resistors are 1/16W, unless otherwise noted.
4. All resistors are Carbon type, unless otherwise
noted.
 
C
 : Solid
W
 : Cement
 
S
 : Oxide Film
 
T
 : Special
 
N
 : Metal Coating
CAPACITOR
1. All capacitors are 
µ
F, unless otherwise noted.
(P=pF=
µµ
F).
2. All capacitors are 50V, unless otherwise noted.
3. All capacitors are Ceramic type, unless otherwise
noted.
(ML): Mylar
(TA): Tantalum
(PF): Polypro Film
(ST): Styrol
BESCHREIBUNG DES
SCHEMATISCHEN SCHALTPLANS
SPANNUNGSMESSUNGEN:
1. Spannungen an den Prüfpunkten werden bei einer
Netzspannung von 230V gemessen, Signale werden
für die Wartung mit einem Farbbalken-Signal
generator zugeführt, und Spannungen werden mit
einem Meßinstrument (20 k
/V) ermittelt.
SIGNALFORMMESSUNGEN:
1. Die Wellenformen an den Testpunkten werden bei
einer Netzspannung von 230V verfolgt. Signale
werden für die Wartung mit einem Farbbalken-Signal
generator zugeführt.
BEZEICHNUNG DES WIDERSTANDS UND
KONDENSATORS:
WIDERSTAND
1. Die Widerstandseinheit “
” wird weggelassen.
(K=k
=1000 
, M=M
).
2. Alle Widerstände haben 
±
 5%, sofern nicht anders
angegeben.
(J= 
±
 5%, F= 
±
 1%, D= 
±
 0.5%)
3. Alle Widerstände haben 1/16W, sofern nicht anders
angegeben.
4. Alle Widerstände sind Kohletyp, sofern nicht anders
angegeben.
 
C
 : Fest
W
 : Zement
 
S
 : Oxidefilm
 
T
 : Spezial
 
N
 : Metallüberzug
KONDENSATOR
1. Die Kapazitätseinheit ist 
µ
F, sofern nicht anders
angegeben.
(P=pF=
µµ
F).
2. Alle Kondensatoren haben 50V, sofern nicht anders
angegeben.
3. Alle Kondensatoren sind Keramiktyp, sofern nicht
anders angegeben.
(ML): Mylar
(TA): Tantal
(PF): Polyprofilm
(ST): Styrol
CAUTION:
This circuit diagram is original one, therefore there may be a
slight difference from yours.
SAFETY NOTES:
1. DISCONNECT THE AC PLUG FROM THE AC
OUTLET BEFORE REPLACEING PARTS.
2. SEMICONDUCTOR HEAT SINKS SHOULD BE
REGARDED AS POTENTIAL SHOCK HAZARDS
WHEN THE CHASSIS IS OPERATING.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH “
  å
 (                  ) ARE
IMPORTANT FOR MAINTAINING THE SAFETY OF
THE SET. BE SURE TO REPLACE THESE PARTS
WITH SPECIFIED ONES FOR MAINTAINING THE
SAFETY AND PERFORMANCE OF THE SET.
ACHTUNG:
bei diesem Schaltplan handelt es sich um den ursprünglichen.
Esönnen daher geringfügige Unterschiede zu dem lhrem bestehen.
SICHERHEITSANMERKUNGEN:
1. VOR DEM AUSWECHSELN VON TEILEN MUSS
UNBEDINGT NETZSTECKER AUS DER
NETZSTECKDOSE GEZOGEN WERDEN.
2. DIE WARMEABLEITER DER HALBLEITER SOLLTEN
BEIM BETRIEB DES CHASSIS ALS MÖGLICHE
URSACHEN VON GEFÄHRLICHEN ELEKTRISCHEN
SCHLÄGEN BETRACHTET WERDEN.
WICHTIGE SICHERHEITSANMERKUNGEN:
MIT “
å
 (                    )BEZEICHNETEN TEILE SIND
BESONDERS WICHTIG FÜR DIE AUFRECHTERHALTUNG
DER SICHERHEIT . BEIM WECHDIESER TEILE SOLLTEN
DIE VORGESCHRIEBENEN TEILE IMMER VERWENDET
WERDEN, UM SOWOHL DIE SICHERHEIT ALS AUCH DIE
LEISTUNG DES GERÄTES AUFRECHTZUERHALTEN.
99
17
16
19
18
15
14
13
12
11
10
XG-C40XU/XE
WAVEFORMS / WELLENFORMEN
e
Q6003 Emitter
(CHROMA signal)
H : 10
µ
sec/div
V : 0.2V/div
5
SC1301 18-pin
(BP SIG5)
H : 10
µ
sec/div
V : 2V/div
1
SC1101 18-pin
(RP SIG5)
H : 10
µ
sec/div
V : 2V/div
9
P801 4-pin
(B-Y)
H : 20
µ
sec/div
V : 1V/div
2
SC1101 19-pin
(RP SIG6)
H : 10
µ
sec/div
V : 2V/div
3
SC1201 18-pin
(GP SIG5)
H : 10
µ
sec/div
V : 2V/div
4
SC1201 19-pin
(GP SIG6)
H : 10
µ
sec/div
V : 2V/div
7
P801 1-pin
(R)
H : 10
µ
sec/div
V : 0.5V/div
8
P801 2-pin
(G)
H : 20
µ
sec/div
V : 0.5V/div
6
SC1301 19-pin
(BP SIG6)
H : 10
µ
sec/div
V : 2V/div
w
Q6008 Emitter
(Y-signal)
H : 10
µ
sec/div
V : 0.2V/div
q
Q422 Emitter
(4FSC)
H : 50
µ
sec/div
V : 0.5V/div
0
IC604 6-pin
(H-OUT)
H : 20
µ
sec/div
V : 1V/div
Page of 115
Display

Click on the first or last page to see other XG-C40XE (serv.man15) service manuals if exist.