PG-M20S
PG-M20X
Checking of Component Input 
(except 480I)
Feed the component signal to 
INPUT 1.
Select INPUT 1 using the set's 
key or the remote controller.
Is the color normal?
Is the signal type set at component?
Set the signal type to component.
Carry out the process adjustment.
Is the picture appear?
IC8013 or IC8025 is defective.
No
Go to "Checking of SOG Circuit".
No
No
Is the contour of picture clear?
Yes
Yes
No
Yes
The component is normal. End.
4
4
» 
PC I/F Unit-8/12
45
PG-M20S
PG-M20X
Checking of SOG Circuit
Check pin (2) of IC8365 by 
oscilloscope.
The SOG sync separation circuit 
(input PWB) is defective.
Is there the Y signal including sync 
signal?
Check the land of C8070 by 
oscilloscope.
Is the composite sync signal 
reproduced in correct timing?
No
Go to "Confirmation of Input 
Signal Setting".
No
The SOG circuit is normal. 
End.
Yes
Yes
» 
PC I/F Unit-9/12
46
PG-M20S
PG-M20X
Feed the composite video signal to 
INPUT 3.
Select INPUT 3 using the set's key 
or the remote controller.
Is there any disturbance in the 
picture?
The video input is normal. End.
Is the color normal?
Is the picture appear?
Go to "Checking of Video 
Sync Signal".
No
Yes
Input PWB is defective.
Q8002 and its periphery are 
defective.
IC8015 is defective.
No
Is there the specified signal 
at R8114?
No
5
5
No
Checking of Video Input
Go to "Checking of Video 
Sync Signal".
Carry out the process 
adjustment.
Yes
No
Yes
Check the clock signal of IC8015 
by FL8114.
Is the clock signal normal?
Yes
IC8025 and its periphery are 
defective.
Yes
Yes
Is the video signal inputted to 
C8141?
No
Go to "Checking of Video Sync 
Signal".
» 
PC I/F Unit-10/12
47
PG-M20S
PG-M20X
Checking of Video Sync Signal
Check pin (10) of IC8363 by 
oscilloscope.
 (Checking of vertical sync signal)
Check pin (6) of IC8363 by 
oscilloscope.
 (Checking of horizontal sync signal)
Are the horizontal sync signal and 
vertical sync signal outputted at 
TL8130 and TL8131?
Is the vertical sync signal normal?
Is the horizontal sync signal 
normal?
Yes
Go to "Confirmation of Input Signal 
Setting".
No
Yes
Is there the specified clock 
(13.5 MHz) signal at FL8114?
Yes
End
Yes
No
IC8015 and its periphery are 
defective.
IC8015 and its periphery are 
defective.
No
No
» 
PC I/F Unit-11/12