Sharp PG-C30XE Handy Guide ▷ View online

Maintenance Indicators
Version 1.4
Issue 04/2006
9
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Maintenance indicator
Condition
Problem
Possible Solution
• 
Blocked air intake
• 
Relocate the projector to
an area with proper
ventilation.
Temperature warning indicator
The internal
temperature is
abnormally high.
• 
Cooling fan breakdown
• 
Internal circuit failure
• 
Clogged air intake
• 
Take the projector to
your nearest Sharp
Authorised Projector
Dealer or Service Centre
Time to change
the lamp
• 
Remaining lamp life
becomes 6% or under.
Lamp replacement indicator
The lamp does not
illuminate.
• 
Burnt-out lamp
• 
Lamp circuit failure
• 
Carefully replace the
lamp. Take the projector
to your nearest
• 
Sharp Authorised
Projector Dealer or
Service Centre for repair.
• 
Please exercise care
Power Indicator
The power indicator
blinks in red when the
projector is on.
• 
The filter cover, lamp unit
cover or lens cover is
open.
• 
Securely install the
covers.
• 
If the power indicator
blinks even when the
filter cover is securely
installed, contact your
nearest Sharp
Authorised Projector
Dealer or Service Centre
for advice.
Important Information
• 
If the temperature warning indicator illuminates, and the power turns off, follow the above possible
solutions and then wait until the projector has cooled down completely before plugging in the power
cord and turning the power back on. (At least 5 minutes.)
• 
If the power is turned off and then turned on again, as during a brief test, the lamp replacement
indicator may be triggered, preventing the power from going on. Should this occur, take the power
cord out of the wall outlet and plug it back in again.
• 
If you want to clean the air vents during projector operation, be sure to first press “OFF” and after
the power has turned off and the cooling fan has stopped, then clean the vents.
• 
Do not unplug the power cord after the power has been turned off and while the cooling fan is
running. The cooling fan runs for about 90 seconds.
Lamp Replacement Procedure
Version 1.4
Issue 04/2006
10
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Lamp
• 
It is recommended that the lamp be replaced after approximately 1,400 cumulative hours
of use or when you notice a significant deterioration of the picture and colour quality.
Carefully change the lamp by following the steps below.
• 
For lamp replacement, please consult your nearest Sharp Authorised Projector Dealer or Service
Centre.
Caution Concerning the Lamp
• 
This projector utilises a pressurised mercury lamp. A loud sound may indicate lamp failure. Lamp
failure can be attributed to numerous sources such as: excessive shock, improper cooling, surface
scratches or deterioration of the lamp due to a lapse of usage time. The period of time up to failure
largely varies depending on the individual lamp and/or the condition and the frequency of use. It is
important to note that failure can often result in the bulb cracking.
• 
When the lamp replacement indicator and on-screen display icon are illuminated or flash, it is
recommended that the lamp be replaced with a new one immediately, even if the lamp appears to
be operating normally.
• 
Should the lamp break, the glass particles may spread inside the lamp cage or gas contained in the
lamp may be vented into the room from the exhaust vent. Because the gas in this lamp includes
mercury, ventilate the room well if the lamp breaks and avoid all exposure to the released gas. In
case of exposure to the gas, consult with a doctor as soon as possible.
• 
Should the lamp break, there is also a possibility that glass particles may spread inside of the
projector. In such a case, it is recommended you contact your nearest Sharp Authorised Projector
Dealer or Service Centre to remove the damaged lamp and assure safe operation.
Replacing the Lamp
*Caution*
• 
Do not remove the lamp unit immediately after operation of the projector. The lamp will be
hot and touching it can lead to burn or injury.
• 
Wait at least one hour after the power cord is disconnected to allow the surface of the
lamp unit to fully cool before removing the lamp unit.
• 
If the new lamp does not light after replacement, take your projector to the nearest Sharp
Authorised Projector Dealer or Service Centre for repair. Purchase a replacement lamp
unit of type BQC-PGC30XE/1 from your nearest Sharp Authorised Projector Dealer or
Service Centre. Then carefully change the lamp by following the instructions described in
this section. If you wish, you may have the lamp replaced at your nearest Sharp
Authorised Projector Dealer or Service Centre.
Part Number
Description
Price Rank
PFILD0076CEZZ
Air Filter
AE
BQC-PGC30XE/1
Lamp Module
CK
Lamp Replacement Procedure
Version 1.4
Issue 04/2006
11
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Removing and Installing the Lamp Unit
Note
• 
Be sure to remove the lamp unit by the handle. Be sure not to touch the glass surface of
the lamp unit or the inside of the projector.
• 
To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps
below.
• 
Do not loosen other screws except for the lamp unit cover and lamp unit. (Only the silver
screws are loosened).
• 
Please refer to the installation manual included with the lamp unit.
1. 
Press “OFF” on the projector to turn off the
power.
• 
Wait until the cooling fan stops.
Warning!
• 
Do not remove the lamp unit from the projector right after
use. The lamp will be very hot and may cause burn or
injury.
2. 
Disconnect the power cord.
• 
Unplug the power cord from the AC socket.
• 
Leave the lamp until it has fully cooled down (about 1 hour). 
3. 
Change the air filter.
• 
Change the air filter whenever you install the lamp unit.
4. 
Remove the lamp unit cover.
• 
Loosen the user service screw that secures the lamp unit
cover. Then slide the cover in the direction of the arrow.
 
Lamp Replacement Procedure
Version 1.4
Issue 04/2006
12
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
5. 
Remove the lamp unit.
• 
Loosen the securing screws from the lamp unit. Hold
the lamp unit by the handle and pull it in the direction
of the arrow. 
6. 
Insert the new lamp unit.
• 
Press the lamp unit firmly into the lamp unit compartment.
Fasten the securing screws. 
7. 
Attach the lamp unit cover.
• 
Insert the tab of the lamp unit cover into the opening, and
press the cover until it clicks in place. 
Note
• 
If the lamp unit and lamp cover are not correctly installed,
the power will not turn on, even if the power cord is
connected to the projector.