Sharp MX-M950 / MX-MM1100 (serv.man15) Service Manual ▷ View online

MX-M1100  DSPF SECTION  C – 17
5)
Remove the screw (a), and remove the fulcrum plate (b).
Remove the lower door (c).
6)
Remove the E-ring (a), and remove the paper guide (b).
7)
Remove the screw (a) and the step screw (b), and remove the
paper guide (c).
8)
Remove the screw (a), and disconnect the connector (b), and
remove the DSPF paper pass sensor 7 (c).
* When installing the sensor, check to confirm that the sensor
boss (d) is securely engaged and fix it with the screw.
9)
Remove the E-ring (a), the belt (b), the pulley (c), and the pin
(d). Remove the E-ring (e), and slide the bearing (f) and
remove the transport roller 3 unit (g).
10) Remove the bearing (a) and the E-ring (b) from the transport
roller 3 (c).
a
b
c
a
b
a
a
c
b
a
b
c
d
a
b
c
d
e
f
g
a
c
b
a
MX-M1100  DSPF SECTION  C – 18
E. Scanner section
(1) Scanner lamp/ CCD unit
1)
Remove the front cabinet and the rear cabinet.
2)
Remove the screw (a), and remove the back surface scanning
section glass upper unit (b).
3)
Disconnect the connector (a). Remove the screw (b), and 
remove the lamp unit (c).
* When installing the lamp unit, wind the harness (a) around
the lamp unit and insert it so that the harness can be easily
pulled out from the rear side.
4)
Remove the screw (a), and remove the scanner lamp (b).
5)
Remove the spring (a). Remove the holder (b), and remove
the arm (c).
Parts
Page
A
Scanner lamp
C - 18/ (1)
B
CCD unit
C
DSPF CL inverter PWB
C - 19/ (2)
B
A
C
a
b
a
c
b
a
a
b
a
b
c
MX-M1100  DSPF SECTION  C – 19
6)
Remove the screw (a), and remove the cover (b). Disconnect
the connector (c).
7)
Remove the step screw (a).
8)
Remove the screw (a), and remove the fulcrum plate (b). 
Remove the scanner unit (c).
9)
Remove the screw (a). Remove the dark box (b) and the cover
(c).
10) Remove the screw (a), and remove the CCD unit (b).
(2) DSPF CL inverter PWB
1)
Remove the rear cabinet.
2)
Disconnect the connector (a), and remove the screw (b). 
Remove the holder (c).
c
a
b
a
a
b
c
a
a
b
c
a
a
a
a
b
a
b
c
MX-M1100  DSPF SECTION  C – 20
3)
Remove the screw (a) and the plate (b), and remove the DSPF
CL inverter PWB (c).
F. Paper exit section
(1) DSPF paper exit detection sensor
1)
Remove the front cabinet and the rear cabinet.
2)
Remove the document tray unit.
3)
Remove the paper feed unit.
4)
Remove the screw (a), and remove the double feed detection
unit (b).
* The harness is connected, be careful not to disconnect it.
5)
Remove the E-ring (a), and remove the No. 1 resist roller (idle)
(b).
6)
Remove the screw (a) and the step screw (b), and remove the
paper guide (c).
7)
Remove the screw (a), and remove the mounting plate (b). 
Disconnect the connector, and remove the screw (d). Remove
the DSPF paper exit sensor (e).
* When installing the sensor, check to confirm that the sensor
boss (f) is securely engaged and fix it with the screw.
Parts
Page
A
DSPF paper exit detection sensor
C - 20/ (1)
B
Transport roller 5
C - 21/ (2)
C
Paper exit roller
a
a
c
b
B
C
A
a
a
b
b
a
c
a
b
a
a
b
c
d
e
f
Page of 27
Display

Click on the first or last page to see other MX-M950 / MX-MM1100 (serv.man15) service manuals if exist.