SHARP
 
TEST SIMULATION
  
 
57
 
30
 
Sensor Operation & Self-Test 
01  Main unit sensor check 
02  Paper feed sensor check (main body) 
 
40
 
Bypass Tray Operation & Self-Test 
02  Bypass tray width adjustment 
07  Bypass tray width detection manual setting 
12  Tray 4 width detection adjustment 
 
41
 
Original Size Operation & Adjustment 
01  Document sensor operation check 
04  Document sensor output setup 
05  Document sensor output display/check 
 
43
 
Fuser Setting & Adjustment 
01  Fuser temperature setup for each mode 
02  Fusing operation and preheat setting 
20  Fuser temperature. correction for low 
temperature & humidity (L/L) 
21  Fuser temp correction for high temperature 
& humidity (H/H) 
24  Fuser temperature correction setting 
31  Fusing web cleaning motor operation check 
32  Set forcible operation of fusing web cleaning 
at job end 
35  Fusing NIP operation check 
 
44
 
Process Control Data & Execution 
01  Process control mode setting 
02  Process control sensitivity adjustment 
03  OPC drum surface potential detection check 
04  Process control initial density setup  
05  Dark potential adjustment setting 
06  High density process control correction  
09  Process control data display 
12  DM data, patch/base data display 
14  Fuser temp.& humidity output data 
15  OPC drum idle rotation setting 
21  Half tone process control registration 
22  Half tone process control patch result 
24  Half tone correction data result display 
25  Initial half tone correction data display 
26  Half tone process control execution 
27  Half tone process control correction clear 
28  Process control timing (On/Off) setting 
29  Enable/disable half tone correction during 
each job 
 
44
 
Process Control Data & Execution 
33  Half tone potential adjustment correction 
(force) 
35  Half tone potential data display 
37  DV bias correction level setting for 
continuous print mode. 
62  Process control execution condition setting 
 
46
 
Copy/Scanner Image Density Adjustment 
02  B/W copy density adjustment 
04  Image Send Colour scan density adjustment 
05  Image Send B/W scan density adjustment 
08  Colour scanner balance adjustment RGB 
09  Scan image density adjustment 
10  Copy grey balance & gamma manual 
adjustment  
16  B/W copy density & gamma (engine balance) 
adjustment 
19  B/W auto exposure mode setup 
23  Enable/disable maximum density adjustment 
for copy mode 
24  Copy half tone auto adjustment 
32  Document background density adjustment 
37  B/W image reproduction adjustment 
39  Fax Image send sharpness adjustment 
40  Fax mode exposure adjust (All modes) 
41  Fax mode exposure adjust (Normal) 
42  Fax mode exposure adjust (Fine Text) 
43  Fax mode exposure adjust (Super Fine) 
44  Fax mode exposure adjust (Ultra Fine) 
45  Fax mode exposure adjustment (600dpi) 
46  Fax mode exposure adjustment (RGB RIP) 
47  JPEG compression rate setting  
48  Function setting for copy output 
51  Heavy paper mode gamma adjustment 
52  Heavy paper mode gamma default set 
54  Engine half tone density adjustment (dither). 
55  Drop out colour mode adjustment for Image 
Send mode. 
60  Sharpness adjustment (colour auto mode) 
61  Area separation recognition setting 
62  ACS operating condition setting 
63  Copy low density adjustment 
66  Watermark reproduction adjustment for 
Copy/Printer 
68  Auto resolution setting 
74  Copy half tone balance adjustment 
 
 
TEST SIMULATION 
SHARP  
 
58
 
46
 
Copy/Scanner Image Density Adjustment 
90  Set process operation of high compression 
PDF images 
91  Black text reproduction adjustment 
 
48
 
Magnification & Motor Adjustment 
01  Scan image magnification adjust (Main scan) 
05  Scan image magnification adjust (Sub scan) 
06  Motor rotation speed adjustment 
 
49 
ROM Version Upgrade 
01  Firmware Upgrade Program 
03  E Manual (Op manual) Update Program 
05  Watermark Update Program 
06  OCR Dictionary Update Program 
 
50
 
Image Position Adjustment 
01  Lead edge/copy position & image loss 
adjustment 
05  Printer lead edge adjustment (sub scan) 
06  SPF Lead edge/copy position adjustment  
10  Print off-centre deviation adjustment. 
12  Original centre deviation adjustment. 
27  Image loss adjustment (Fax/Scanner) 
28  Service automatic adjustment (OC/SPF 
position & BK magnification etc) 
 
51
 
Resist Roller Adjustment 
01  Secondary transfer voltage ON timing adjust 
02  Resist roller adjustment 
 
53
 
Document Feeder Adjustment 
06  SPF document tray size adjustment 
07  SPF document tray size adjust value set. 
08  SPF scanning position adjustment 
09  SPF dirt detection setting 
10  SPF dirt detection execution 
 
55
 
MFP Data Setting 
01  Engine soft switch setting 
02  Scanner soft switch setting 
03  Controller soft switch setting 
 
SW1-5 
Auto clear function before copy 
job execution:- 
 
 
0 =Disabled, 1 = Enabled 
 
 
 
 
55
 
MFP Data Setting 
03  Controller soft switch setting 
 
SW3-6 
Process mixed original size 
printing for duplex mode:- 
 
 
0 =Disabled, 1 = Enabled 
 
SW3-7 
HP Compatibility Mode:- 
 
 
0 =Disabled, 1 = Enabled 
 
SW4-5 
Paper type simplification 
selection:- 
 
 
0 =Disabled, 1 = Enabled 
 
SW4-7 
Custom paper feed size entry:- 
 
 
0 =Disabled, 1 = Enabled 
 
SW6-1 
Ethernet Speed Auto negotiation:- 
 
 
0 = Enabled, 1 = Disabled 
 
SW6-2 
Ethernet Link Speed:- 
 
 
0 = 100Base TX, 1 = 10Base T 
 
SW6-3 
Ethernet Duplex Mode:- 
 
 
0 = Full, 1 = Half 
 
SW6-4 
Ethernet 100/1000 Link Speed:- 
 
 
0 = 100Base TX, 1 = 1000Base T 
 
 
0 =Disabled, 1 = Enabled 
 
SW9-4 
Offset mode for multiple copies of 
a single original:- 
 
 
0 =No Offset, 1 = Offset 
 
SW9-5 
Maintenance notification setting 
by Printer MIB:- 
 
 
0 = Enabled, 1 = Disabled 
 
SW17-3 
A3 / Postcard Counter Mode 
 
 
0 = Disabled, 1 = Enabled 
 
SW18-6 
Hide Device Counter Clear  
(SIM24-6 to 24-15) 
 
 
0 = Hide [Default], 1 = Display 
 
SW22-5 
 
Display toner remaining (MFP 
Status):- 
 
 
0= Disabled, 1 = Enabled/Display 
 
SW22-7 
How to clear Fusing Web Roller 
counter at life end:- 
 
 
0 = Clear with SIM (Default) 
1 = Clear by initial detection 
 
SW24-7 
Continuous print mode for OSA 
(job queuing for MXAMX3):- 
 
 
0 = Job Queue Disabled 
1 = Job Queue Enabled 
 
SW24-8 
OSA Offline Mode (for external 
accounting):- 
 
 
0 = Disabled, 1 = Enabled 
 
 
SHARP
 
TEST SIMULATION
  
 
59
 
55
 
MFP Data Setting 
03  Controller soft switch setting 
 
SW26-2 
Notification sound for Stop copy 
when no original is present 
 
 
0 = Disabled,  
1 = Enabled 
 
 
0 = CR3 series (Default) 
1 = CR2 series 
 
SW27-8 
Retain Scan to Desktop 
destination for a certain period 
after a scan operation. 
 
 
0 = Disabled (Default) 
1 = Enabled 
 
SW28-3 
Single Email alert notification for 
customer. 
 
 
0 = Disabled (Default) 
1 = Enabled 
 
SW30-5 
Authenticate the User already 
logged in by being authenticated 
with Active Directory or not when 
receiving print data 
 
 
0 = Authenticate 
1 = Not Authenticate (Default) 
 
SW32-2 
Frequency to obtain remaining 
toner information using MIB 
 
 
0 = Every 25% (Default) 
1 = Every 5% 
10 
Special Stamp setting (Taiwan only) 
 
56
 
MFP Data Export & Import 
01  Transfer data execution (MFP/SRAM/ 
EEPROM to HDD) 
02  Backup EEPROM/SSD/HDD operation data to 
USB memory 
03  Document filing data backup to USB memory 
04  Job log data backup to USB memory 
05  Export SIM22-06 (Adjustment & Settings 
data) to USB memory 
06  Output SIM23-02 Jam/Trouble data to USB 
memory 
07  Export Syslog data to USB memory 
08  Export ICC Colour profile to USB memory 
15  Import EEPROM data 
99  Export ALL Log data (SIM56-02/04/05/06/07 
& SIM00-11) to USB memory 
 
60
 
MFP Data Setting 
01  SDRAM read/write test (MFP PWB) 
 
61
 
LSU Writing Adjustment & Self-Test 
01  LSU test (Polygon & BD detection check) 
03  LSU power auto setup 
04  LSU print image skew adjustment 
11  LSU power correction (automatic) 
12  LSU power manual correction 
13  LSU power correction value reset/clear 
14  LSU power setting collective input 
 
62
 
HDD Operation & Self-Test 
01  HDD format  
02  HDD partial read/write check 
03  HDD read/write check (all areas) 
06  Smart (HDD) self-diagnostic test  
07  Smart (HDD) self-diagnostic error log 
08  HDD format (excluding system & operation 
manual area) 
10  Job completion list clear (with job log) 
11  Document filing data clear 
12  Enable/disable auto format for HDD trouble 
13  HDD format (Operation manual & Watermark 
data only) 
14  Delete document filing management data 
20  Check operation of mirroring hard disk 
 
63
 
CCD Operation & Adjustment 
01  Shading correction data display 
02  Shading correction execution (force) 
03  CCD gamma & colour correction adjustment 
04  Scanner test chart patch density list display 
05  CCD colour balance and gamma default 
setting 
06  Set the auto adjustment pattern of engine 
and grey balance. 
07  Register the standard target of copy mode 
auto colour balance adjustment (Service) 
08  Set the standard copy mode auto colour 
balance target to factory default (Service) 
11  Set the standard target colour balance 
adjustment (Factory) 
 
64
 
Self-Test Print 
02  Self-test print (B/W mode) 
03  Self-test print (B/W mode – high speed 
process) 
04  Printer self-print test 
05  Printer self-print test (PCL) 
*
 
06  Printer self-print test (PS) 
*
 
 
 
TEST SIMULATION 
SHARP  
 
60
 
65
 
LCD Operation & Adjustment 
01  LCD touch panel adjustment 
02  LCD touch panel adjustment result display 
05  Operation panel key input test 
 
66
 
Image Send Settings & Adjustments 
01  Image send Soft SW setting 
 
SW24 
Communication Signal sending 
level (bits 1-8): 
Default Value (Australia/NZ) 
00001011
 
 
SW27-4 
V.34 mode function (call arrival): 
0 = V.34 valid, 1 = V.34 invalid. 
 
SW27-5 
V.34 mode function (polling when 
calling): 
0 = V.34 valid, 1 = V.34 invalid. 
 
SW27-6 
V.34 mode function (manual 
communication): 
0 = V.34 valid. 1 = V.34 invalid. 
 
SW33-6, 
SW33-7; 
Transmission cable amplitude 
equaliser:- 
00 = 0dB, 01 = 4dB 
10 = 8dB, 11 = 12dB
 
02  Image send Soft SW clear 
03  Fax PWB controller memory check 
04  Fax signal line check (Max level)  
05  Fax signal line check (Soft SW setting level) 
06  Fax list print (confidential registration) 
07  Fax memory printout (all data) 
08  Fax sound message setup 
09  Fax signal line check (Soft SW setting) 
10  Image data all memory clear 
11  Fax voice signal check (line/speaker 300bps) 
12  Fax voice signal check (line/speaker 300bps) 
13  Fax register dial number for Sim 66-14/15/16 
14  Fax adjust/check the time dial pulse (10bps) 
15  Fax adjust/check the time dial pulse (20bps) 
16  Fax adjust/check the send level DTFM signal 
17  Fax DTFM signal to send to line (Max level) 
18  Fax DTFM signal to send to line (Soft Sw 
level) 
21  Fax print various registration information 
22  Fax sound volume of the handset setting 
24  Fax fast memory data clear 
25  Fax number registration for modem dial in 
26  Fax register external tel. number for Modem 
dial in 
29  Image Send address data clear 
30  Fax Tel/LIU sensor status check 
 
66
 
Image Send Settings & Adjustments 
31  Fax ON/OFF setting of output port (Tel/LIU) 
32  Fax received data check (comparison) 
33  Fax busy tone/CNG/CED/FNET detect check 
34  Fax display time required for sending test 
data 
36  Fax Send/Receive from modem check. 
39  Fax destination saved in Fax EEPROM check 
42  Fax PIC program installed on Fax box. 
43  Write program & adjustment values to PIC 
installed on Fax 
61  Display FAX related soft switch (151-250) 
62  FAX receive data export in PDF format. 
 
67
 
Printer Settings & Adjustments 
17  Printer NVRAM clear 
24  Printer half tone auto adjustment  
25  Printer half tone manual adjustment  
26  Set the target colour balance for printer 
mode auto colour adjustment 
27  Setup target of printer calibration (Service)  
28  Standard target of printer calibration 
(Service)  
31  Printer calibration data clear  
33  Printer screen gamma adjust. (PCL/PS)  
34  Printer maximum density adjustment mode  
36  Adjust the density in printer low density 
areas  
52  Printer default gamma check (PCL/PS)  
54  Printer colour balance adjustment  
 