Sharp MX-M623U / MX-M753U (serv.man6) Handy Guide ▷ View online

 
 
 
 
Initial Set-up 
 
 
 
 
ENGINE & PRINTER HALF-TONE - CALIBRATION  
 
 
Sim 46-24  
Automatic Half Tone Calibration  
 
 
Select FACTORY Mode.  
Note: Engine & Printer Half Tone Calibration is performed 
together (ie. One scan) and must be completed.  
 
 
 
 
 
 
IMAGE DENSITY  
        
       Sim 46-02   
Copy Exposure Adjust.  
       Sim 46-04   
Scanner Density Adjust (Colour).  
       Sim 46-05   Scanner Density Adjust (Mono).  
Sim 46-09   DSPF Copy Density Adjust.  
 
 
 
 
PRINTER DENSITY  
 
 
Sim 64-05      PCL Density Test Page.  
Sim 64-06      PS Density Test Page.  
                        (when PS option is installed)  
 
 
 
 
 
FAX OPTION (MX-FXX2)  
 
Sim 66-02      Fax SW Setting (Destination).  
Sim 66-10      Fax Memory Clear (For Extended 
                        Memory).  
Sim 66-39      Fax Destination Set.  
 
 
 
 
 
FINISHER OPTION (MX-EBX3)  
 
 
Sim 22-05       
ACRE firmware ver  03.00.j2(or higher)  
 
 
 
 
 
 
 
 
 
 
 
 
Initial Set-up 
 
FINISHER OPTION (MX-FN16)  
 
 
Sim 03-10       
Saddle Fold/Staple Position adjustment.  
 
 
 
 
 
 
EXTERNAL KEYBOARD OPTION 
 
Keyboard Language Setting:-  
System Settings – Default Settings – Keyboard 
Select 
 
Select English (US). 
 
 
 
 
 
USB PORT SETTING 
 
 
Set Active USB Port (MFP Control PWB DIP)  
SW2 OFF (Front - Default), ON (Rear)  
 
Note: Both USB Ports are active when MX-KBX2  
Is installed.  
 
 
 
 
 
MFP STATUS DISPLAY 
 
 
Sim 55-03        Toner Remaining Status Display 
                          SSW 22, Data/Bit 5 
                          (Change from 0 to 1) 
                           
 
 
 
 
 
 
OTHER 
 
 
Sim 22-06        
Data Simulation Print. 
System Settings: Adjust Clock (Set Date, Time & Time Zone). 
Device Clone & Storage Backup:  
                          Backup System Settings,  
                          Scan Destinations, User Control, 
                          OSA Configuration after customer    
                          Installation is complete. 
 
 
 
 
 
 
 
Maintenance 
 
Manual Density & Graduation Adjustment - SERVICE MODE 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Engine 
 
 
 
 
 
Printer 
 
 
Sim 46-24 
Auto Half Tone Calibration 
Service Mode 
 
 
 
 
Sim 67-24 
Auto Harftone image Correction 
Service mode 
 
Sim 46-16 
Manual Half Tone Adjustment 
(Adjust 15 points for engine) 
Sim 67-25 
Manual Half Tone Adjustment:  
Adjust (15 points) for printer.  
 
 
 
 
 
 
Continue Engine Procedure  
 
 
Sim 64-05 & 64-06  
Printer Test Page  
PCL & PS Printer Density Check  
(PS where fitted).
 
 
 
 
 
Sim 44-21 
Register Half Tone Adjustment 
 
 
Continue Printer Procedure  
 
 
Sim 63-07 
Service Target Balance Setup: 
Scan Test Pattern.
 
 
 
 
Sim 67-27  
Service Target Balance Setup:  
Scan Test Pattern
 
 
 
Sim 44-06 
High Density Process Control Correction 
(Forcible Execution) 
 
Sim 44-26  
Half Tone Image Correction:  
Half Tone Correction Forcible Execution  
 
Sim 46-24  
Auto Half Tone Adjustment  
(Engine & Printer)  
Service Mode  
Place printed test pattern onto glass  
 
 
 
 
 
Maintenance 
 
 
 
 
 
 
 
 
Consumable Quick Reference Guide: 
 
Total Maintenance
 
300K 
600K 
900K 
1200K 
1500K 
Process 
Drum 
AR-620DM 
 
 
 
 
 
Developer 
MX-753GV 
 
 
 
 
 
Maintenance Kit 1 
MX-753KA 
 
 
 
 
 
Fuser 
Maintenance Kit 2 
MX-753KB 
 
 
 
 
 
Transfer 
Maintenance Kit 3 
MX-753KC 
 
 
 
 
 
 
Maintenance Indications: 
 
TA 
Black Drum (Counter) has reached  
Specified limit. 
 
 
DK 
Black Drum (Counter) has reached  
Specified life. 
Replace OPC Drum 
Process 
Section 
(Drum) 
VK 
Black Developer (Counter) has reached  
The specified life.  
Replace Developer.  
Process 
Section 
(Developer)  
FK3 
Upper Fuser Web Cleaning Counter has reached 
the specified limit.  
Replace upper Fuser 
Web Cleaning Kit.  
Fuser Section  
FK4 
Lower Fuser Web Cleaning Counter has reached 
the specified limit.  
Replace Lower Fuser 
Web Cleaning Kit.  
Fuser Section  
 
Starting Powder: 
 
The following starting powder should be applied to the relevant consumable item during maintenance:- 
 
Model 
OPC Drum 
MX-M623N 
MX-M753N 
 
UKOG-0312FCZZ 
[Stearic Acid Powder] 
 
Page of 44