DOWNLOAD Sharp MX-M310 / MX-M310N (serv.man3) Service Manual ↓ Size: 10.65 MB | Pages: 127 in PDF or view online for FREE

Model
MX-M310 MX-M310N (serv.man3)
Pages
127
Size
10.65 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual (Revised November 2014).
File
mx-m310-mx-m310n-sm3.pdf
Date

Sharp MX-M310 / MX-M310N (serv.man3) Service Manual ▷ View online

MX-M260/M310/M260N/M310N  SIMULATION 6 - 16
Operation/procedure
Used to clear each paper feed counter individually.
1.
Select the counter to be cleared with the 10-key. 
2.
Press the [START] key. The confirmation menu is shown. 
3.
Select “1: YES.”
1: YES (Cleared)
2: NO (Not cleared) (Default)
Operation/procedure
Used to clear the original and staple counters individually. 
1.
Select the counter to be cleared with the 10-key. 
2.
Press the [START] key.
The confirmation menu is shown. 
3.
Select “1: YES.”
1: YES (Cleared)
2: NO (Not cleared) (Default)
Operation/procedure
1.
Press the [START] key. The confirmation menu is shown.
2.
Select “1: YES.”
1: YES (Cleared)
2: NO (Not cleared) (Default)
Operation/procedure
1.
Press the [START] key.
The confirmation menu is shown. 
2.
Select “1: YES.”
1: YES (Cleared)
2: NO (Not cleared) (Default)
Operation/procedure
1.
Press the [START] key.
The confirmation menu is shown.
2.
Select “1: YES.”
1: YES (Cleared)
2: NO (Not cleared) (Default)
Operation/procedure
1.
Press the [START] key.
The confirmation menu is shown. 
2.
Select “1: YES.”
1: YES (Cleared)
2: NO (Not cleared) (Default)
Operation/procedure
1.
Select the counter to be cleared with the 10-key.
2.
Press the [START] key.
The confirmation menu is shown. 
3.
Select “1: YES.”
1: YES (Cleared)
2: NO (Not cleared) (Default)
24-2
Purpose
Data clear
Function 
(Purpose)
Used to clear the number of use (the number of prints) 
of each paper feed section.
Section
Paper feed
Item
Counter
Item
Content
1
BYPASS
Manual feed counter
2
TRAY1
Tray 1 counter
3
TRAY2
Tray 2 counter
4
TRAY3
Tray 3 counter
5
TRAY4
Tray 4 counter
24-3
Purpose
Data clear
Function 
(Purpose)
Used to clear the number usage data of the stapler, 
RSPF, and scanning.
Section
Transport/Finisher
Item
Counter
Item
Content
1
SPF
RSPF counter
2
SCAN
Scan counter
3
STAPLE
Stapler counter
24-4
Purpose
Data clear
Function (Purpose)
Used to reset the maintenance counter.
Item
Counter
24-5
Purpose
Data clear
Function 
(Purpose)
Used to reset the developer counter. (The developer 
counter of the DV unit which is installed is reset.)
Section
Image process 
(Photoconductor/Developing/Transfer/Cleaning)
Developer/Toner hopper
Item
Counter
Developer
24-6
Purpose
Data clear
Function (Purpose)
Used to clear the copy counter.
Item
Counter
Copier
24-7
Purpose
Data clear
Function 
(Purpose)
Used to clear the OPC drum (membrane decrease) 
correction counter. (This simulation is executed when 
the OPC drum is replaced.)
Section
Image process 
(Photoconductor/Developing/Transfer/Cleaning)
Photo conductor
Item
Counter
24-9
Purpose
Data clear
Function 
(Purpose)
Used to clear the printer counter and other counters. 
Section
Printer
Item
Counter
Printer
Item
Content
1
PRINTER
Printer counter
2
IMC
IMC counter
3
DUPLEX
DUPLEX counter
4
OTHERS
The other counters
MX-M260/M310/M260N/M310N  SIMULATION 6 - 17
Operation/procedure
1.  Select the “3: NUMBER OF PRINTS”, and press the [START] key.
The confirmation menu is shown. 
2.
Select “1: YES.”
1: YES (Cleared)
2: NO (Not cleared) (Default)
Note: Executable only when the FAX is installed.
Operation/procedure
1.
Press the [START] key.
The confirmation menu is shown. 
2.
Select “1: YES.”
1: YES (Cleared)
2: NO (Not cleared) (Default)
The scanner mode counter and the number of send of the scanner are
cleared.
* The simulation to perform communication with the PCL is inhibited
until Notice Page storing is completed. (Only when the serviceman
call error occurs.)
* When in other than the serviceman call error, entering the simulation
is not allowed from the system check display. 
Operation/procedure
1.
Press the [START] key.
The main motor rotates to start monitoring the toner density control
sensor. (3min operation)
* Even in toner end error, if there is no other error (including cover
open) after turning on the power, this simulation can be performed.
Operation/procedure
1) Open the cover with the power OFF.
2) Turn on the power. (Since the cover is open, the machine does not
perform initializing.)
3) Execute the simulation. 
4) Enter SIM 25-2. ([25] 
 [START] key 
 [2] 
 [START] key)
5) Close the cover just before starting the simulation. 
6) Press the [START] key. 
The main motor rotates. After stirring for 3 min, the toner density
control sensor value is sampled 16 times, and the average value is
stored. 
When “EE-EU” or “EE-EL” after completion, an error display is shown.
Note: After completion of execution, be sure to press the [CA] key to
cancel the simulation.
Operation/procedure
1.
Select the set value with the 10-key.
2.
Press the [START] key.
Operation/procedure
1.
Select the item with the 10-key and press the [START] key.
Used to set the automatic size detection.
2.
Set whether automatic detection of paper size is made or not with
the 10-key.
8.5” x 13” detection valid/invalid setup
24-10
Purpose
Data clear
Function (Purpose)
FAX counter data clear
Section
FAX
Item
Counter
Item
Content
1
FAX SEND 
(PAGE & TIME)
FAX send page and time
2
FAX RECEIVE 
(PAGE & TIME)
FAX receive page and time
3
FAX OUTPUT
FAX output (number of prints)
24-15
Purpose
Data clear
Function 
(Purpose)
Used to clear the scanner counter in the network 
scanner mode.
Section
Scanner section
Item
Counter
25
25-1
Purpose
Operation test/check
Function 
(Purpose)
Used to check the operation of the main drive 
(excluding the scanner section) and to check the 
operation of the toner concentration sensor. (The toner 
concentration sensor output can be monitored.) 
Section
DRIVE
Item
Operation
25-2
Purpose
Setting
Function 
(Purpose)
Used to make the initial setting of toner concentration 
when replacing developer.
Section
Image process 
(Photoconductor/Developing/Transfer/Cleaning)
Developer/Toner hopper
26
26-1
Purpose
Setting
Function 
(Purpose)
Used to set whether the job separator is installed or 
not. (Since this cannot be detected by hardware 
detection, it is set in this simulation.)
Item
Specifications
Option
Set value
Connection option
0
None (default)
1
Job separator provided.
26-2
Purpose
Setting
Function 
(Purpose)
Used to set whether the automatic detection of paper 
size is made or not.
Section
Paper feed
Item
Specifications
1:B4/LG,FC
Setting to detect B4/Legal as FC
0 : B4 legal is detected as B4 legal. (Default)
1 : B4 legal is detected as FC.
2:A4<->LT
This setup detects Letter as A4 in the inch series and 
A4 as Letter in the AB series.
0 : Detection disable (Default)
1 : Detection valid
Set value
Setup
Remarks
0
Detection invalid
Default
1
Detection valid
MX-M260/M310/M260N/M310N  SIMULATION 6 - 18
Detection size when 8.5” x 13” document/paper is used.
A4/LT (8.5” x 11”) detection enable/disable setup
In the inch series, Letter is detected as A4; in the AB series, A4 is
detected as Letter.
Detection size when A4/LT (8.5” x 11”) document/paper is used.
Operation/procedure
Select the mode corresponding to the auditor specification mode with
the 10-key.
When “1: VENDOR (Coin vendor mode)” is set, the following three
items of key operation setting are changed. 
1) Set the LCD backlight change inhibit to “1: OFF (Enable).”
2) When SIM 26-6 destination setting is set to “0: Japan,” duplex copy
inhibit setting must be set to “0: ON (Inhibit).”
3) Set the sort automatic selection to “0: OFF (Disable).”
Operation/procedure
Used to set the count up number (1 or 2) when an A3/WLT paper 
passes through.
For the drum counter and the developer counter, double count is 
employed unconditionally.
(Target counter selection)
Used to set the count up number of the selected counter.
Operation/procedure
Select the destination with the 10-key.
By changing the destination, some other setting items may be changed.
Employed 
unit
Destina
tion
Document 
size
Set value
0
(Invalid)
1
(Valid)
Docu
ment
Document 
table/
RSPF
AB 
series
FC 
(8.5” x 13”)
B4
FC 
(8.5” x 13”)
LG 
(8.5” x 14”)
B4
FC 
(8.5” x 13”)
B4
B4
FC 
(8.5” x 13”)
Inch 
series
FC 
(8.5” x 13”)
LG 
(8.5” x 14”)
FC 
(8.5” x 13”)
LG 
(8.5” x 14”)
LG 
(8.5” x 14”)
FC 
(8.5” x 13”)
B4
WLT 
(11” x 17”)
WLT 
(11” x 17”)
Paper
Machine 
paper feed 
tray
All 
destina
tions
Set with key operations.
Manual 
paper feed 
tray
AB 
series
FC 
(8.5” x 13”)
LG 
(8.5” x 14”)
FC 
(8.5” x 13”)
LG 
(8.5” x 14”)
LG 
(8.5” x 14”)
FC 
(8.5” x 13”)
B4
B4
B4
Inch 
series
FC 
(8.5” x 13”)
LG 
(8.5” x 14”)
FC 
(8.5” x 13”)
LG 
(8.5” x 14”)
LG 
(8.5” x 14”)
FC 
(8.5” x 13”)
B4
B4
B4
Set value
Setup
Remarks
0
Detection invalid
Default
1
Detection valid
Employed 
unit
Destina
tion
Document 
size
Set value
0
(Invalid)
1
(Valid)
Docu
ment
Document 
table/
RSPF
AB 
series
A4
A4
LT 
(8.5” x 11”)
LT 
(8.5” x 11”)
A4
LT 
(8.5” x 11”)
Inch 
series
A4
LT 
(8.5” x 11”)
A4
LT 
(8.5” x 11”)
LT 
(8.5” x 11”)
A4
Paper
Machine 
paper feed 
tray
All 
destina
tions
Set with key 
operations.
Manual 
paper feed 
tray
All 
destina
tions
Regardless of the 
simulation setup.
26-3
Purpose
Setting
Function 
(Purpose)
Used to set the specifications of the auditor. 
Setting must be made depending on the use condition 
of the auditor.
Section
Auditor
Item
Specifications
Item
Content
Setting 
range
Default
0
P10
Built-in auditor mode
0-2
0
1
VENDOR
Coin vendor mode
2
OTHER
Others
26-5
Purpose
Setting
Function 
(Purpose)
Used to set the count mode of the total counter and the 
maintenance counter.
Item
Specifications
Counter
Item
Content
1
TOTAL COUNTER
Total counter
2
MAINTENANCE COUNTER
Maintenance counter
Item
Content
Setting range
Default
1
SINGLE COUNT
Single count
1-2
2
2
DOUBLE COUNT
Double count
26-6
Purpose
Setting
Function 
(Purpose)
Used to set the specifications depending on the 
destination.
Item
Specifications
Destination
Item
Content
Setting 
range
Default
0
JAPAN
Japan
0-14
0
1
SEC
SEC
2
SECL
SECL
3
SEEG
SEEG
4
SUK
SUK
5
SCA
SCA
6
SEF
SEF
7
INEG
EX inch series
8
ABEG
EX AB series
9
INEF
EX inch series (FC)
10
ABEF
EX AB series (FC)
11
CHINESE
China
12
TAIWAN
Taiwan AB
13
SEEG2
SEEG2
14
TAIWAN2
Taiwan China
MX-M260/M310/M260N/M310N  SIMULATION 6 - 19
Operation/procedure
Enter the set value with the 10-key and press the [START] key.
If the trial scanner counter value is less than 500, the trial mode setting 
can be repeatedly made. If the scanner trial counter value is 500 or 
more, the trial mode setting cannot be made. 
When the scanner is not set and the scanner trial counter value is less 
than 500, if “1” is entered in SIM26-10, the trial mode setting is started. 
If “0” is entered in SIM26-10, the trial mode setting is canceled. 
After recognition of the scanner, the trial mode setting cannot be made. 
(Entering “1” is invalid and a beep sound is produced.)
When this setting is made, the machine must be reset after canceling 
the simulation. When “1: Trial mode start” is selected, the scanner 
function is valid. If “0: Trial mode cancel” is selected, the scanner func-
tion is invalid. 
When setting is invalid (when the scanner is recognized or the scanner 
trial counter value is 500 or more) in the key operations of the trail 
mode setting, an invalid sound (beep sound) is made. In the other 
case, a valid sound is made.
* When the scanner trial counter value is changed from 500 or more to
less than 500, the trail setting is changed from “END” to “SETTING
START.”
Note: Executable only when the PCL/SCANNER is installed.
Operation/procedure
The current setup is displayed with ON or OFF.
Enter an input (20 digits) of the E-MAIL RIC soft key with the 10-key
and press the [START] key, and the collating result is displayed with OK
or NG.
After canceling the simulation, if OK, the E-MAIL RIC function is
enable; if NG, the E-MAIL RIC function is disabled.
This setting must be reset after the simulation cancel.
* If recognition is OK, the E-Mail RIC can be set to Enable. If the FAX
is installed, however, the operation cannot be made actually.
Note: Executable only when the PCL/NIC is installed.
Operation/procedure
The current setup is displayed with ON or OFF.
Enter an input (20 digits) of the PS expansion kit soft key with the 10-
key and press the [START] key, and the collating result is displayed
with OK or NG.
After canceling the simulation, if OK, the PS expansion kit function is
enable; if NG, the PS expansion kit function is disabled.
This setting must be reset after the simulation cancel.
Note: Executable only when the PCL/PS3 is installed.
Operation/procedure
Input the set value with the 10-key and press the [START] key.
Note: Setup is allowed only for Japan and UK.
 
Operation/procedure
Select the display language with the 10-key, and press the [START]
key.
This setup varies in connection with SIM 26-6 (Destination setup).
26-10
Purpose
Setting
Function (Purpose)
Network scanner trial mode setting
Section
Scanner
Item
Content
Default
0
END
Trail mode cancel
0
1
START 
Trial mode start
26-12
Purpose
Setting
Function 
(Purpose)
Used to input the Software Key for E-MAIL RIC.
Section
E-MAIL RIC
Item
Specifications
26-14
Purpose
Setting
Function 
(Purpose)
Used to input the Software Key for the PS extention kit.
Section
Printer
Item
Specifications
26-18
Purpose
Setting
Function 
(Purpose)
Used to set enable/disable of toner save operation.
Item
Specifications
Operation mode (Common)
Item
Content
Setting 
range
Default
0
OFF
Disable
0-1
0
1
ON
Enable
26-22
Purpose
Setting
Function 
(Purpose)
Used to set the specification (language display) for the 
destination.
Item
Specifications
Item
Remarks
0
JAPANESE
1
ENG.US
2
ENG.UK
3
FRENCH
4
GERMAN
5
ITALY
6
DUTCH
7
SWEDISH
8
SPANISH
9
PORTUGUESE
10 TURKISH 
11 GREEK
12 POLISH
13 HUNGARIAN
14 CZECH
15 RUSSIAN
16 FINNISH
17 NORWEGIAN
18 DANISH
19 CHINESE
20 TAIWANESE
Traditional Chinese supported locally
21 SLOVAK
22 HEBREW
Supported locally
23
BRAZILIAN 
PORTUGUESE
24 ARABIC
25 FARSI
Page of 127
Display

Click on the first or last page to see other MX-M310 / MX-M310N (serv.man3) service manuals if exist.