Sharp MX-M282N / MX-M502N (serv.man24) Service Manual / Technical Bulletin ▷ View online
Sharp Electronics (UK) Ltd., Technical Services Group
1. Model Name: MX-M282N/M362N/M452N/M502N
2. Description: Upgrade of ICU and SCU-ROM
From August 2011 Production
ROM control No.
ICU
PCU
SCU
E-MANUAL
B01
0103i3
0101i3
0201j3
0120i3
* ICU above is the version described in the ROM management label. Check that the actual
version is: ICU(MAIN): 01.03.i3/ICU(BOOT): 01.00.i3/LANGUAGE: 01.02.i3/GRAPHIC: 01.0.
j3; by Sim22-5.
version is: ICU(MAIN): 01.03.i3/ICU(BOOT): 01.00.i3/LANGUAGE: 01.02.i3/GRAPHIC: 01.0.
j3; by Sim22-5.
Item of change: See the attached sheet
ROM Version Combination History Table
No.
ROM control No.
ICU
PCU
SCU
E-MANUAL
Action
T/R No.
(4)
B00
0102i3
0101i3
0200j3
0120i3
2011/6
ARE-1041
(3)
A12
0102i3
0101i3
0102j3
0120i3
2010/11
ARE-1020
(2)
A02
0102i3
0101i3
0102j3
0110i3
2010/10
ARE-1013
(1)
A01
0101i3
0100i3
0102j3
0110i3
2010/7
ARE-1003
ROM UPGRADE..... (5).
TECHNICAL BULLETIN
Date:
11
th
August 2009
Model:
MXM282 – M502
Ref.:
Colour:
White
Page:
1 of 1
Sharp Electronics (UK) Ltd., Technical Services Group
[Description]
No.
Item
Details
1 Copier
When the Copy key was pressed after placing the original on the
document feeder, the copy key command would be processed first
before the processing to determine the paper size on the document
feeder, and as the result of it, the original was scanned from the
document glass, which might cause the "blank page" output. This
problem has been corrected.
document feeder, the copy key command would be processed first
before the processing to determine the paper size on the document
feeder, and as the result of it, the original was scanned from the
document glass, which might cause the "blank page" output. This
problem has been corrected.
2 Scanner
As the countermeasure for the lines when scanning the data from the
document feeder, we have added the mode to search the most
uncontaminated scan position on start-up (when power ON) and also
on completion of scanning the job from the document feeder to the
Soft SW so that it becomes possible to scan from the most
uncontaminated scan position from the next scanning of the job from
the document feeder.
document feeder, we have added the mode to search the most
uncontaminated scan position on start-up (when power ON) and also
on completion of scanning the job from the document feeder to the
Soft SW so that it becomes possible to scan from the most
uncontaminated scan position from the next scanning of the job from
the document feeder.
Scanner Control Soft SW (Sim55-2)
SW No. 8 Data 1, 2, 3
SW No. 8 Data 1, 2, 3
0, 0, 0: [ON] both on start-up/on completion of the job (Default)
0, 0, 1: [ON] only on start-up
0, 1, 0: [ON] only on completion of the job
1, 0, 0: [OFF] both on start-up/on completion of the job
0, 0, 1: [ON] only on start-up
0, 1, 0: [ON] only on completion of the job
1, 0, 0: [OFF] both on start-up/on completion of the job
3 Image Send
Sending to a file server using "Scan to SMB" is not possible. This
problem has been corrected.
problem has been corrected.
4 Image Send
If the destination was set to \\servername\folder when using "Scan
to Network Folder", the error (NG800000) occurred. This problem
has been corrected.
to Network Folder", the error (NG800000) occurred. This problem
has been corrected.
5 Image Send
If Windows Live Essentials 2011 is installed on Windows7/Vista,
scan to shared folder was not usable. This problem has been
corrected.
scan to shared folder was not usable. This problem has been
corrected.
6 Files
When printing with specifying the multiple files using the Multi-File
Print function, the "No file is found" error occurred. This problem
has been corrected.
Print function, the "No file is found" error occurred. This problem
has been corrected.
7 Others
"Eup Lot4" that is one of the European environment standards has
now been supported.
now been supported.
Display