Sharp MX-M232D (serv.man3) Service Manual ▷ View online

MX-M182 SIMULATIONS 7-57
66
31
TEL/LIU setting
The following bit 0/1 is alternatively switched. At the same time, the target signal name is highlighted.
32
Receive data check
Used to check receive data from the line and judge whether the following receive data and the judged data 
number accord together or not. If they accord, "OK" is notified. If not, "NG" is notified. Judgment is made 
from the receive start data and the data must be accorded continuously.
Main 
code
Sub 
code
Contents
Remark
Sim66-31 TEL OUTPUT
Sim66-31 TEL OUTPUT
After selection
with numeric keys
[OK] key
[OK] key
[BACK] key
Sim66-31 TEL OUTPUT
1:CION
 2:150VON
3:EC  
4:S
(1 - 5) 
X
1:CION 5:MSR
 EXEC
1:CION 5:MSR
PRESS BACK TO STOP
 
EXEC
Sim66-31 TEL OUTPUT
5:MSR
(1 - 5) 
X
Selection of two or more items can be made.
(The selected numbers are highlighted.)
Though numeric keys is pressed in the sequence
of "1 and 5" or "5 and 1," the display is made
in the sequence of the normal order
(1 and 5) when OK key is pressed.
After pressing [OK] key,
during execution
[CA] key 
: Simulation cancel
[INTERRUPT] key : Sub code input window
Numeric keys 
: Item selection
[OK] key 
: Input value settlement and execution
[START] key 
: Input value settlement and execution
[BACK] key 
: Returns to the selection window
         keys 
: Page switch
[C] key 
: Input value clear. ON when highlighted.
Sim66-32 RECV DATA
[OK] key
Sim66-32 RECV DATA
Sim66-32 RECV DATA
CHECK RECEIVE DATA
  
EXEC
RESULT XX
 
After pressing 
[OK] key,
during 
execution
RECEIVING
 
EXEC
Simulation code input window
"RECEIVING" is displayed 
only during receive. 
[CA] key 
: Simulation cancel
[INTERRUPT] key : Sub code input window
[OK] key 
: Settlement
[START] key 
: Settlement
[BACK] key  : Simulation code input window
[C] key 
: Disable
XX 
: "OK/NG" is displayed 
Completion of 
execution
(Highlighted 
 during execution)
[BACK] key
MX-M182 SIMULATIONS 7-58
66
33
Signal detection check
Used to detect signals and display the result with ON/OFF.
34
Communication time measurement
Used to perform a send/receive test and measure and display the time required for send/receive of the 
image data in the communication.
37
Speaker sound volume adjustment
Used to adjust the speaker sound volume.
During execution of this simulation, the following test sound is sent to the line and the speaker. 
The send level to the line is set to the soft SW setting value. 
The speaker sound volume can be adjusted by the operation.
The type of sound can be selected among the following:
1.Call sound, 2.Line monitor sound, 3.On-hook, 4.Terminating sound, 5.Communication end sound, 
6.DTMF send sound
For each type of sound, the sound volume can be selected among the following:
No sound, Small, Medium, Large
The set value is written into each soft  SW. 
Main 
code
Sub 
code
Contents
Remark
CI  :     FNET:
 EXEC
Sim66-33 SIGNAL CHK
CNG :     CED :
BT  :     DT  :
 EXEC
Sim66-33 SIGNAL CHK
1:CI FNET
2:CNG CED BT DT
3:Flag SDT DTMF
   (1 - 3) 
X
Sim66-33 SIGNAL CHK
Flag:     SDT :
DTMF:
 EXEC
[OK] key
[OK] key
[BACK] key
[OK] key
[BACK] key
[OK] key
[BACK] key
Sim66-33 SIGNAL CHK
CI  :OFF  FNET:OFF
DETECT 
EXEC
Sim66-33 SIGNAL CHK
CNG :OFF   CED :OFF
BT  :OFF 
DT  :OFF
DETECT 
EXEC
Sim66-33 SIGNAL CHK
Flag:OFF  SDT :OFF
DTMF:OFF
DETECT 
EXEC
Sim66-33 SIGNAL CHK
After selection with numeric key
After pressing [OK] key,
during execution
After pressing [OK] key,
during execution
After pressing [OK] key,
during execution
SIM66-33 initial window
SIM66-33 initial window
SIM66-33 initial window
1:CI FINET
2:CNG CED BT DT
3:Flag SDT DTMF
[CA] key 
: Simulation cancel
[INTERRUPT] key : Sub code input window
[C] key 
: Input clear
Numeric key 
: Item selection
[ON] key 
: Input value settlement and execution
[START] key 
: Similar to OK key
Signal detection
YES/NO is displayed
with ON/OFF.
Signal detection
YES/NO is displayed
with ON/OFF.
Signal detection
YES/NO is displayed
with ON/OFF.
Sim66-34 COMM. TIME
[OK] key
[BACK] key
Sim66-34 COMM. TIME
  
EXEC
COMM. TIME:
 xxx:xx:xx:xxxms
 
Simulation code
input window
[CA] key 
: Simulation cancel
[INTERRUPT] key : Sub code input window
[OK] key 
: Settlement
[BACK] key 
: Simulation code input window
[START] key 
: Settlement
[C] key 
: Disable
Immediately after 
pressing [OK] key, the 
window shifts to the 
next one.
Type of sound
Test sound
Sound volume setting value
0
1
2
3
1.Call sound
Call sound
No Sound
Small
Medium
Large
2.Line monitor sound
Communication signal 
sound (33600bps)
No Sound
Small
Medium
Large
3.On-hook
Communication signal 
sound (33600bps)
Setting 
disable
Small
Medium
Large
4.Terminating sound
Read end sound
No Sound
Small
Medium
Large
5.Communication end sound Communication end 
sound
No Sound
Small
Medium
Large
6.DTMF send sound
DTMF send sound
No Sound
Small
Medium
Large
MX-M182 SIMULATIONS 7-59
66
37
The following soft SW's are newly provided. 
The following soft SW's are not affected
SW55-4 - 5 Send end sound
SW55-6 - 7 Receive end sound
38
Time setting/check
Used to write/read the time (year, month, day, o'clock, minute) into/from the RTC on the FAX PWB.
Main 
code
Sub 
code
Contents
Remark
Type of sound
Soft SW number
1. Sound volume of call sound
SW 53-3 - 4
Sound volume of call sound (Low)
SW131-5 - 8
Sound volume of call sound (Medium)
SW132-1 - 4
Sound volume of call sound (High)
SW132-5 - 8
2. Line monitor speaker sound volume
SW 52-5 - 6
Line monitor speaker sound volume (Low)
SW127-1 - 4
Line monitor speaker sound volume (Medium)
SW127-5 - 8
Line monitor speaker sound volume (High)
SW128-1 - 4
3. On-hook speaker sound volume
SW 53-1 - 2
On-hook speaker sound volume (Low)
SW130-1 - 4
On-hook speaker sound volume (Medium)
SW130-5 - 8
On-hook speaker sound volume (High)
SW131-1 - 4
4. Scan end speaker sound volume
SW 52-1 - 2
Scan end speaker sound volume (Low)
SW124-1 - 4
Scan end speaker sound volume (Medium)
SW124-5 - 8
Scan end speaker sound volume (High)
SW125-1 - 4
5. Communication end speaker sound volume
SW 52-7 - 8
Communication end speaker sound volume (Low)
SW128-5 - 8
Communication end speaker sound volume (Medium)
SW129-1 - 4
Communication end speaker sound volume (High)
SW129-5 - 8
6. DTMF send speaker sound volume
SW 52-3 - 4
DTMF send speaker sound volume (Low)
SW125-5 - 8
DTMF send speaker sound volume (Medium)
SW126-1 - 4
DTMF send speaker sound volume (High)
SW126-5 - 8
[OK] key
After selection 
with numeric keys
[BACK] key
[OK] key
After selection 
with numeric keys
XX: The current set 
value is displayed.
YY: Input in the 
range of 1(Low) - 
15 (High) .
A sound beeps at the 
set sound volume. 
While the speaker is 
sounding, [EXEC] is 
highlighted.
Press [BACK] key to 
stop the sound. 
[OK] key
Sim66-37 SPEAKER
1:RINGER
2:LINE MONITOR
3:ON HOOK
( 1 - 6 ) 
X
Window display
1
ȇRINGER
2
ȇLINE MONITOR
3
ȇON HOOK
4
ȇSCAN FINISH
5
ȇTX/RX FINISH
6
ȇDTMF
Sim66-37 SPEAKER
ON HOOK
1:SMA.2:MED.3:LAR.
( 1 - 3 ) 
X
Sim66-37 SPEAKER
ON HOOK
SMALL -
 XX
( 1 - 15 ) 
YY
Sim66-37 SPEAKER
ON HOOK
SMALL -
 XX
( 1 - 15 ) 
YY
Sim66-37 SPEAKER
ON HOOK
SMALL -
PRESS BACK TO STOP
 
EXEC
Press [BACK] key to 
stop the sound.
After inputting 
with numeric key
While [EXEC] is 
highlighted, a 
sound beeps. 
Sim66-38 DATE & TIME
Sim66-38 DATE & TIME
Sim66-38 DATE & TIME
Sim66-38 DATE & TIME
DATE
MONTH XX
(1-12) YY
DATE
DAY XX
(1-31) YY
YEAR 20YY
MONTH YY
DAY YY
 EXEC
After inputting 
with numeric 
key, press 
[OK] key.
[OK] key
[OK] key
After inputting 
with numeric 
key, press 
[OK] key.
[OK] key
After inputting 
with numeric 
key.
[OK] key
After inputting 
with numeric 
key.
[OK] key
Sim66-38 DATE & TIME
TIME XX:XX
(00-59) YY
xx: The current year/month/day 
      is displayed.
yy: The input value is displayed. 
xx: The current time is displayed.
yy: The input value is displayed.
[CA] key 
: Simulation cancel
[INTERRUPT] key : Sub code input window
Numeric keys 
: Item selection and time input
[OK] key 
: Settlement
[START] key : Settlement
[BACK] key  : Returns to the previous window or
 
  the simulation code input window. 
[C] key 
: Input value clear
After execution, the 
display shifts to the sub 
code input window. 
DATE
YEAR XXXX
(2011-2062) YY
MX-M182 SIMULATIONS 7-60
66
42
PIC program writing
Used to write the program again into the power control which is installed to the FAX BOX.
43
PIC adjustment value writing
Used to write the adjustment value of the program into the power control which is installed to the FAX BOX.
Default:
1: 6
2: 10
3: 142
4: 3
5: 15
6: 240
7: 2
8: 20
52
Pseudo ringer check 
• The pseudo ringer sound is delivered both from the machine (speaker).
• This operation is continued until the interruption command is made by pressing RETURN key.
• The LCD displays the TEL/LIU status and the HOOK status.
• While the pseudo ringer is delivered, the RBT )ring back tone) is delivered to the line. The bell is ON for 
1sec and OFF for 2sec. 
67
50
USB reception speed adjustment
Used to set an limitation on the print data reception speed when the USB transfer speed is at full speed.
* When images are disturbed in printing through USB, change the setting and try again.
[CA] key: Exits from the simulation mode. 
[INTERRUPT] key: Shifts to the sub code entry window. 
Default:
3
Main 
code
Sub 
code
Contents
Remark
[OK] key
[BACK] key
Sim66-42 PIC RELOAD
Sim66-42 PIC RELOAD
ARE YOU SURE?
  
EXEC
Sim66-42 PIC RELOAD
OK
  
EXEC
[CA] key 
: Simulation cancel
[INTERRUPT] key : Sub code input window
[OK] key 
: Settlement
[BACK] key 
: Returns to the simulation 
 
  code input window.
ARE YOU SURE?
 
EXEC
Sub code input window
During execution, [EXEC] is 
highlighted. 
Incase of writing 
error, "NG" is 
displayed. 
After pressing 
[OK] key, during 
execution
Window display
Setting 
range
1:CI_LEVEL_JUDGE
2 - 15
2:CI_CYCLE_MIN
1 - 254
3:CI_CYCLE_MAX
2 - 255
4:CI_COUNT
2 - 15
5:RES_3.3V_LEVEL_JUDGE
2 - 15
6:EXHS_LEVEL_JUDGE
2 - 255
Window display
Setting 
range
7:RHS_LEVEL_JUDGE
2 - 15
8:SON_TIMEOUT
1 - 127
9:WRITE
-
Window display
Setting 
range
[OK] key
[OK] key
After inputting 
with numeric 
key
9. When 
WRITE is 
selected
SIM66-43 initial window
XX: The current set value is displayed.
YY: Input value
Sim66-43 PIC ADJUST
1:CI LEVEL
2:CI CYCLE MIN
3:CI CYCLE MAX
( 1 - 9 ) 
X
Sim66-43 PIC ADJUST
CI LEVEL
 XX
( 2 - 15 ) 
YY
[OK] key
After inputting 
with numeric 
key
Sim66-43 PIC ADJUST
OK
  
EXEC
After execution, the display shifts
to the sub code input window. 
Sim66-43 PIC ADJUST
ARE YOU SURE?
 
EXEC
During execution, [EXEC] is 
highlighted. 
Incase of writing 
error, "NG" is 
displayed. 
[BACK] key
[CA] key 
: Simulation cancel
[INTERRUPT] key : Sub code input window
[OK] key 
: Settlement
[BACK] key 
: Returns to the simulation 
 
  code input window.
Sim66-52 PSEUDO RNG
Sim66-52 PSEUDO RNG
PSEUDO RINGER CHK
  
EXEC
Sim66-52 PSEUDO RNG
PSEUDO RINGER CHK
  
EXEC
After pressing 
[OK] key, during 
execution
PSEUDO RINGER CHK
PRESS BACK TO STOP
 
EXEC
[CA] key 
: Simulation cancel
[INTERRUPT] key : Sub code input window
[OK] key 
: Execution
[BACK] key 
: Returns to the selection window.
[START] key 
: Execution
[C] key 
: Disable
[BACK] key
[OK] key
Sim67-50  USB SPEED
1:FULL SPEED
2
2
Display : 
Setting
1 : 
FAST
: NORMAL 1
: NORMAL 2
4 : 
SAFE
[      1-   4]
Slow
Fast
Page of 127