Sharp MX-M1055 / MX-M1205 (serv.man6) Handy Guide ▷ View online

SHARP
 
FIRMWARE UPDATE
  
 
33
 
 
 
5.  Press Execute to start the firmware update. 
 
Note:   Once the machine has entered “service download mode”, the update will commence and the 
progress will be displayed. 
 
 
 
6.  When the upgrade is complete, click Reboot to execute a remote restart of the machine. 
 
 
 
 
Firmware Upgrade is complete
FIRMWARE RECOVERY 
SHARP  
 
34
 
In the event of a power failure during a firmware update, the device may fail to “reboot” because of 
corrupted firmware. Using the CN Update procedure described below, this function is used to 
update/recover the firmware by transferring data to the MFP PWB, SCU PWB, PCU PWB, FAX PWB, and 
various options by means of a USB memory. 
 
MENU KEY REFERENCE: 
 
The following five keys are used to perform firmware recovery mode. For MX-M904-1205 series, touch the 
LCD panel within the area shown below to select the desired key:- 
 
 
 
 
 
 
 
           [UP]                           [BACK] 
 
 
 
 
 
 
 
 
              
       [DOWN]     
         [OK] 
[MENU] 
 
CN UPDATE - Firmware Recovery Procedure:- 
 
1.  Power off the MFP and remove the Right Rear Cabinet & Screws. 
 
2.  Set the MFP PWB UPDATE DIP-SW to ON:- 
 
 
Note: If a Boot failure has occurred, replace the SD Card. 
 
3.  Install the USB Memory containing the MX-M904/1054/1204 or MX-M1055/1205 firmware into the 
USB slot:- 
 
4.  Power ON the MFP device - the UPDATE PROGRAM INIT PLEASE WAIT boot menu should appear  
after approx 10 seconds, followed by VERSION CHECK CONFIG: information:-. 
 
 
 
 
 
 
Version Check 
  Conf: 00050000 
Update Prog Init 
Please wait
 
SHARP
 
FIRMWARE RECOVERY
 
 
35
 
5.  Select FIRM UPDATE Mode by using the [Menu] & [Back] keys. Using the [UP] and [DOWN] keys, 
navigate and select the required firmware SFU. 
 
 
 
 
Note: 
Use the [OK] key when a directory name is selected to browse through to the sub folder(s) or  
the [BACK] key to return to the parent folder(s). 
 
6.  Press [OK] to commence Firmware Update. – It may take approx. 1-2 minutes to read the SFU file. 
After reading is completed, the firmware update (writing) will commence automatically. 
 
 
 
 
 
Note:   
The abbreviated name/location of the firmware that is being updated will appear in the upper  
right corner. 
 
7.  If the firmware upgrade completes successfully, RESULT OK will be displayed:- 
 
 
 
 
8.  Power off the MFP and return the MFP PWB UPDATE DIP-SW to OFF (Default):- 
 
 
 
9.  Power ON the MFP, and confirm that the machine boots up normally. 
 
10. Power OFF the MFP and refit the Right Rear Cabinet & Screws. 
 
 
CN UPDATE - Firmware Recovery Procedure is now complete. 
 
Firm Update 
> 01010000.sfu
 
Firm Update 
    Reading Data
 
Firm Update              IcuM 
    Writing Data
 
Firm Update           IcuM 
    Result  :  OK
 
Firm Update 
    From USB Memory
 
E-MANUAL UPDATE 
SHARP  
 
36
 
1.  Using a PC, copy the E-Manual Update onto the 
root of a USB memory device (as shown). 
 
Note: 
The E-Manual firmware for MX-M904-MX-M1205 
series consists of 1 file (*.UAR). 
 
 
 
2.  Insert the USB memory device into a USB port on 
the machine and execute Simulation 49-03 [E-
MANUAL UPDATE]:- 
 
 
 
3.  Browse the E Manual Directory (eg MANUAL) and 
select the “*.uar” update file:- 
 
 
 
 
 
 
 
 
 
 
 
 
4.  The current and updated version should then be 
displayed:- 
 
 
 
5.  Press Execute to commence upgrade. Update File 
Checking and a progress of the update will be 
displayed:- 
 
 
 
6.  Once the update is complete, press OK to exit 
simulation mode:- 
 
 
 
 
E-Manual update is complete. 
Page of 82
Display