Sharp MX-M1055 / MX-M1205 (serv.man6) Handy Guide ▷ View online
SHARP
FIRMWARE UPDATE
33
5. Press Execute to start the firmware update.
Note: Once the machine has entered “service download mode”, the update will commence and the
progress will be displayed.
6. When the upgrade is complete, click Reboot to execute a remote restart of the machine.
Firmware Upgrade is complete
FIRMWARE RECOVERY
SHARP
34
In the event of a power failure during a firmware update, the device may fail to “reboot” because of
corrupted firmware. Using the CN Update procedure described below, this function is used to
update/recover the firmware by transferring data to the MFP PWB, SCU PWB, PCU PWB, FAX PWB, and
various options by means of a USB memory.
corrupted firmware. Using the CN Update procedure described below, this function is used to
update/recover the firmware by transferring data to the MFP PWB, SCU PWB, PCU PWB, FAX PWB, and
various options by means of a USB memory.
MENU KEY REFERENCE:
The following five keys are used to perform firmware recovery mode. For MX-M904-1205 series, touch the
LCD panel within the area shown below to select the desired key:-
LCD panel within the area shown below to select the desired key:-
[UP] [BACK]
[DOWN]
[OK]
[MENU]
CN UPDATE - Firmware Recovery Procedure:-
1. Power off the MFP and remove the Right Rear Cabinet & Screws.
2. Set the MFP PWB UPDATE DIP-SW to ON:-
Note: If a Boot failure has occurred, replace the SD Card.
3. Install the USB Memory containing the MX-M904/1054/1204 or MX-M1055/1205 firmware into the
USB slot:-
4. Power ON the MFP device - the UPDATE PROGRAM INIT PLEASE WAIT boot menu should appear
after approx 10 seconds, followed by VERSION CHECK CONFIG: information:-.
Version Check
Conf: 00050000
Conf: 00050000
Update Prog Init
Please wait
Please wait
SHARP
FIRMWARE RECOVERY
35
5. Select FIRM UPDATE Mode by using the [Menu] & [Back] keys. Using the [UP] and [DOWN] keys,
navigate and select the required firmware SFU.
Note:
Use the [OK] key when a directory name is selected to browse through to the sub folder(s) or
the [BACK] key to return to the parent folder(s).
Use the [OK] key when a directory name is selected to browse through to the sub folder(s) or
the [BACK] key to return to the parent folder(s).
6. Press [OK] to commence Firmware Update. – It may take approx. 1-2 minutes to read the SFU file.
After reading is completed, the firmware update (writing) will commence automatically.
Note:
The abbreviated name/location of the firmware that is being updated will appear in the upper
right corner.
The abbreviated name/location of the firmware that is being updated will appear in the upper
right corner.
7. If the firmware upgrade completes successfully, RESULT OK will be displayed:-
8. Power off the MFP and return the MFP PWB UPDATE DIP-SW to OFF (Default):-
9. Power ON the MFP, and confirm that the machine boots up normally.
10. Power OFF the MFP and refit the Right Rear Cabinet & Screws.
CN UPDATE - Firmware Recovery Procedure is now complete.
Firm Update
> 01010000.sfu
> 01010000.sfu
Firm Update
Reading Data
Reading Data
Firm Update IcuM
Writing Data
Writing Data
Firm Update IcuM
Result : OK
Result : OK
Firm Update
From USB Memory
From USB Memory
E-MANUAL UPDATE
SHARP
36
1. Using a PC, copy the E-Manual Update onto the
root of a USB memory device (as shown).
Note:
The E-Manual firmware for MX-M904-MX-M1205
series consists of 1 file (*.UAR).
The E-Manual firmware for MX-M904-MX-M1205
series consists of 1 file (*.UAR).
2. Insert the USB memory device into a USB port on
the machine and execute Simulation 49-03 [E-
MANUAL UPDATE]:-
MANUAL UPDATE]:-
3. Browse the E Manual Directory (eg MANUAL) and
select the “*.uar” update file:-
4. The current and updated version should then be
displayed:-
5. Press Execute to commence upgrade. Update File
Checking and a progress of the update will be
displayed:-
displayed:-
6. Once the update is complete, press OK to exit
simulation mode:-
E-Manual update is complete.
Click on the first or last page to see other MX-M1055 / MX-M1205 (serv.man6) service manuals if exist.