DOWNLOAD Sharp MX-LC13 (serv.man15) Service Manual ↓ Size: 11.35 MB | Pages: 68 in PDF or view online for FREE

Model
MX-LC13 (serv.man15)
Pages
68
Size
11.35 MB
Type
PDF
Document
Service Manual / Technical Bulletin
Brand
Device
Copying Equipment / IMPROVEMENTS FOR INSTALLING MX-LC13 N
File
mx-lc13-sm15.pdf
Date

Sharp MX-LC13 (serv.man15) Service Manual / Technical Bulletin ▷ View online

MX-M1204  MX-LC13 (LARGE CAPACITY TRAYS)  8 – 3
7) Underlay the adjustment bolt with the adjuster. (Four positions)
8) Screw the adjustment bolt to adjust the height of MX-LC13.
There is a mark on the mounting plate of the large capacity 2-
stage paper feed tray. Adjust so that the top of the connection
plate in the machine side is aligned with the center of the mark.
9) Fix the positioning plate and with the screws (Packed items
No. 4 S-tight, M4 x 8). 
10) Open the front cabinet and fix the lower cabinet with the screw.
NOTE: Note for separation
When separating, tighten the screw to release the
lock.
When connecting again, loosen the screw after con-
nection.
11) Connect the connector from MX-LC13 to the machine and
tighten the screw.
NOTE: Use an L-shape screwdriver.
12) Adjust the clearance of the exterior cabinet evenly. 
See drawing below.
Front side
[F side]
[R side]
MX-M1204  MX-LC13 (LARGE CAPACITY TRAYS)  8 – 4
Rear side
13) Adjust the height of the exterior cabinet to the same level.
Front side
Rear side
C. When connecting two units
NOTE: Perform the step “D” and later in case of the non dual con-
nection.
1)
Install the MX-RB17.
2)
Attach the LCT connecting plate to the large capacity trays
with the screws (Packed items No. 4 S-tight, M4 x 8).
MEMO: The reference label is attached to the plate. Attach it
so that the label can be seen from the outside.
3)
Attach the connection plates (F/R) to the first-series MX-LC13
with the screws (Packed items No. 4 S-tight, M4 x 8).
4)
Remove the screw, and remove the paper guide cover in the
right side of the first-series MX-LC13.
TopPage
4
: ‘14/Jan
4
MX-M1204  MX-LC13 (LARGE CAPACITY TRAYS)  8 – 5
5) Turn the paper guide cover over and fix it with screws again.
6) Attach the connection plate (Upper) to the first-series MX-
LC13 with the screws (No. 11 Hex washer S-tight M4 x 18).
7) Remove the connector cover of the first-series MX-LC13.
8)
Fit the connection plates (F/R) attached to the first-series MX-
LC13 with the LCT connection plates (F/R) attached to the
second-series MX-LC13.
9)
Ensure even clearance of the upper section between the first
and second series MX-LC13 by pushing the second-series
MX-LC13.
10) Open the front door of the second-series MX-LC13, and
remove the lower cabinet.
TopPage
4
: ‘14/Jan
4
MX-M1204  MX-LC13 (LARGE CAPACITY TRAYS)  8 – 6
11) Underlay the adjustment bolt with the adjuster. (Four positions)
12) Screw the adjustment bolt to adjust the height of MX-LC13.
There is a mark on the mounting plate of the large capacity 2-
stage paper feed tray. Adjust so that the top of the connection
plate in the first-series MX-LC13 side is aligned with the center
of the mark.
13) Fix the positioning plate and with the screws (Packed items
No. 4 S-tight, M4 x 8).
14) Open the front cabinet and fix the lower cabinet with the screw.
15) Attach the harness of the second-series MX-LC13 to the first-
series MX-LC13, and tighten the screw of the harness to fix.
NOTE: Use an L-shape screwdriver.
16) Adjust the clearance of the exterior cabinet evenly.
See drawing below.
Front side
[F side]
[R side]
TopPage
4
: ‘14/Jan
4
Page of 68
Display

Click on the first or last page to see other MX-LC13 (serv.man15) service manuals if exist.