Sharp MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) Service Manual ▷ View online

MX-C400P/C380P, MX-B400P/B380P/B382P  ADJUSTMENTS  4 – 4
Item/Display
Content
Adjustment 
range
Default 
value
Actual output 
setting range
Default value 
of actual 
output value
A
TC1 LOW SPEED CL K
Primary 
transfer bias 
adjustment 
value
Color mode
K
Low speed 
mode
51 - 255
95
2 - 30
A
8
A
B
TC1 MIDDLE SPEED CL K
Middle speed 
mode
51 - 255
131
2 - 30
A
13
A
C
TC1 LOW SPEED CL C
C
Low speed 
mode
51 - 255
95
2 - 30
A
8
A
D
TC1 MIDDLE SPEED CL C
Middle speed 
mode
51 - 255
131
2 - 30
A
13
A
E
TC1 LOW SPEED CL M
M
Low speed 
mode
51 - 255
95
2 - 30
A
8
A
F
TC1 MIDDLE SPEED CL M
Middle speed 
mode
51 - 255
131
2 - 30
A
13
A
G
TC1 LOW SPEED CL Y
Y
Low speed 
mode
51 - 255
95
2 - 30
A
8
A
H
TC1 MIDDLE SPEED CL Y
Middle speed 
mode
51 - 255
131
2 - 30
A
13
A
I
TC1 LOW SPEED BW K
Black/White 
mode
K
Low speed 
mode
51 - 255
95
2 - 30
A
8
A
J
TC1 MIDDLE SPEED BW K
Middle speed 
mode
51 - 255
131
2 - 30
A
13
A
K
TC2 PLAIN CL SPX
Secondary 
transfer bias 
adjustment 
value
Color mode
Standard paper 
mode
Front surface 
mode
51 - 255
111
–2 - –80
A
–25
A
L
TC2 PLAIN CL DPX
Back surface 
mode
51 - 255
124
–2 - –80
A
–30
A
M
TC2 PLAIN BW SPX
Black/White 
mode
Front surface 
mode
51 - 255
111
–2 - –80
A
–25
A
N
TC2 PLAIN BW DPX
Back surface 
mode
51 - 255
111
–2 - –80
A
–25
A
O
TC2 HEAVY CL SPX
Color mode
Heavy paper 
mode
Front surface 
mode
51 - 255
93
–2 - –80
A
–10
A
P
TC2 HEAVY CL DPX 
Back surface 
mode
51 - 255
93
–2 - –80
A
–10
A
Q
TC2 HEAVY BW SPX
Black/White 
mode
Front surface 
mode
51 - 255
93
–2 - –80
A
–10
A
R
TC2 HEAVY BW DPX
Back surface 
mode
51 - 255
93
–2 - –80
A
–10
A
S
TC2 OHP CL
OHP
Color mode
51 - 255
85
–2 - –80
A
–8
A
T
TC2 OHP BW 
Black/White mode
51 - 255
85
–2 - –80
A
–8
A
U
TC2 ENVELOPE CL
Envelope
Color mode
51 - 255
124
–2 - –80
A
–30
A
V
TC2 ENVELOPE BW
Black/White mode
51 - 255
124
–2 - –80
A
–30
A
W
TC2 THIN CL
Thin paper
Color mode
51 - 255
111
–2 - –80
A
–25
A
X
TC2 THIN BW
Black/White mode
51 - 255
111
–2 - –80
A
–25
A
Y
TC2 GLOSSY CL
Gloss paper
Color mode
51 - 255
72
–2 - –80
A
–10
A
Z
TC2 GLOSSY BW
Black/White mode
51 - 255
72
–2 - –80
A
–10
A
AA
TC2 CLEANING
Cleaning mode
51 - 255
67
–2 - -80
A
–8
A
AB
TC2 CLEAN LOW SPD
Secondary 
transfer 
cleaning bias 
adjustment 
value
Low speed print mode
0 - 255
16
–100V - 1500V
0V
AC
TC2 CLEAN MIDDLE SPD
Middle speed print mode
0 - 255
16
–100V - 1500V
0V
AD
TC2 CLEAN CLEANING 
Cleaning mode
0 - 255
143
–100V - 1500V
800V
AE
PTC LOW SPEED CL
PTC current 
output 
adjustment 
value
Color mode
Low speed mode
0 - 255
133
0
A - –700A
–300
A
AF
PTC MIDDLE SPEED CL
Middle speed mode
0 - 255
133
0
A - –700A
–300
A
AG
PTC LOW SPEED BW
Black/White mode
Low speed mode
0 - 255
133
0
A - –700A
–300
A
AH
PTC MIDDLE SPEED BW
Middle speed mode
0 - 255
133
0
A - –700A
–300
A
AI
CASE VOLT LOW CL
PTC case 
voltage 
adjustment 
value
Color mode
Low speed mode
0 - 255
0
0V - –1000V
0V
AJ
CASE VOLT MID CL
Middle speed mode
0 - 255
0
0V - –1000V
0V
AK
CASE VOLT LOW BW
Black/White mode
Low speed mode
0 - 255
0
0V - –1000V
0V
AL
CASE VOLT MID BW
Middle speed mode
0 - 255
0
0V - –1000V
0V
AM
PEEL VOLT LOW CL
Separation 
discharge 
adjustment 
value
Color mode
Low speed mode
51 - 255
200
 –50 - –3000V
–2200V
AN
PEEL VOLT MIDDLE CL
Middle speed mode
51 - 255
200
 –50 - –3000V
–2200V
AO
PEEL VOLT LOW BW
Black/White mode
Low speed mode
51 - 255
200
 –50 - –3000V
–2200V
AP
PEEL VOLT MIDDLE BW
Middle speed mode
51 - 255
200
 –50 - –3000V
–2200V
MX-C400P/C380P, MX-B400P/B380P/B382P  ADJUSTMENTS  4 – 5
: ’11/Mar/15
1
 
ADJ 1
Adjusting high voltage values 
(MX-B400P/B380P/B382P)
 
1-A
Adjust the main charger grid voltage 
(MX-B400P/B380P/B382P)
This adjustment is needed in the following situations:
* When the MC high voltage power PWB is replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
1) Enter the SIM 8-2 mode.
2) Select an output mode and an item to be adjusted.
3) Set the adjustment value (specified value) of the middle speed
mode. (Enter the set value, and press [OK] key and OSA
shortcut key.)
When [EXECUTE] button is selected and [OK] key is pressed,
the voltage corresponding to the value entered in procedure 3)
is outputted for 30 sec and the set value is fixed.
With [EXECUTE] button selected, press [OK] key again, and
the simulation is terminated.
Enter the adjustment value of each mode which is specified on
the label attached on the MC high voltage power PWB.
NOTE: Normally when an adjustment value is set, there is no need
to press [EXECUTE] button. If [EXECUTE] button should
be pressed, a high voltage would be outputted with the
OPC drum stopped, affecting an adverse effect on the
OPC drum. Be careful of that.
NOTE: Note that the adjustment value may differ depending on the
MC high voltage power PWB.
Since the adjustment value label is attached on the MC
high voltage PWB, the PWB must be removed in order to
check the adjustment value.
This is a troublesome procedure. Therefore, it is advisable
to put down the adjustment value in advance.
When the adjustment value (specified value) of the middle speed
mode is set, the adjustment values of the other modes are auto-
matically set according to the middle speed mode setting in a cer-
tain relationship.
NOTE: Since the high voltage output cannot be checked with a
digital multi meter in this model, a judgment of the output
must be made by checking the print image quality.
 
1-B
Adjust the developing bias voltage 
(MX-B400P/B380P/B382P)
This adjustment is needed in the following situations:
* When the MC high voltage power PWB is replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
1)
Go through the modes specified in Simulation 8-1.
2)
Select an output mode and an item to be adjusted.
3)
Set the adjustment value (specified value) of the middle speed
mode. (Enter the set value, and press [OK] key and OSA
shortcut key.)
When [EXECUTE] button is selected and [OK] key is pressed,
the voltage corresponding to the value entered in procedure 3)
is outputted for 30 sec and the set value is fixed.
With [EXECUTE] button selected, press [OK] key again, and
the simulation is terminated.
Enter the adjustment value of each mode which is specified on
the label attached on the MC high voltage power PWB.
NOTE: Normally when an adjustment value is set, there is no need
to press [EXECUTE] button. If [EXECUTE] button should
be pressed, a high voltage would be outputted with the
OPC drum stopped, affecting an adverse effect on the
OPC drum. Be careful of that.
NOTE: Note that the adjustment value may differ depending on the
MC high voltage power PWB.
Since the adjustment value label is attached on the MC
high voltage PWB, the PWB must be removed in order to
check the adjustment value.
This is a troublesome procedure. Therefore, it is advisable
to put down the adjustment value in advance.
1
1
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
˷̚˹
0+9*5,'6(77,1*$1'287387
˖0,''/(ǂ63(('ǂ*%B.
7(67
0,''/(
/2:
(;(&87(
.(<
                        & 
0$,1
Mode
Item/Display
Content
Setting range
MIDDLE
A
MIDDLE 
SPEED GB_K
K charging/grid bias set 
value at middle speed
150 - 850
LOW
A
LOW SPEED 
GB_K
K charging/grid bias set 
value at low speed
150 - 850
Mode
Item/Display
Content
Setting 
range
MIDDLE
A
MIDDLE SPEED 
DVB_K
K developing bias set 
value at middle speed
0-600
LOW
A
LOW SPEED 
DVB_K
K developing bias set 
value at low speed
0-600
1
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
˷̚˹
'96(77,1*$1'287387
˖0,''/(63((''9%B.
7(67
0,''/(
/2:
(;(&87(
.(<
                        & 
0$,1
MX-C400P/C380P, MX-B400P/B380P/B382P  ADJUSTMENTS  4 – 6
: ’11/Mar/15
1
When the adjustment value (specified value) of the middle speed
mode is set, the adjustment values of the other modes are auto-
matically set according to the middle speed mode setting in a cer-
tain relationship.
NOTE: Since the high voltage output cannot be checked with a
digital multi meter in this model, a judgment of the output
must be made by checking the print image quality.
 
1-C
Transfer voltage adjustment 
(MX-B400P/B380P/B382P)
This adjustment is needed in the following situations:
* When the TC high voltage PWB is replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
1) Go through the modes specified in Simulation 8-6.
2)
Select an item to be adjusted.
3)
Set the adjustment value (specified value) of the middle speed
mode. (Enter the set value, and press [OK] key and OSA
shortcut key.)
When [EXECUTE] button is selected and [OK] key is pressed,
the voltage corresponding to the value entered in procedure 3)
is outputted for 30 sec and the set value is fixed.
With [EXECUTE] button selected, press [OK] key again, and
the simulation is terminated.
By setting the default value (specified value), the specified out-
put is provided.
NOTE: Normally when an adjustment value is set, there is no need
to press [EXECUTE] button. If [EXECUTE] button should
be pressed, a high voltage would be outputted with the
OPC drum stopped, affecting an adverse effect on the
OPC drum and the transfer belt. Be careful of that.
1
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
˷̚˹
7+96(77,1*$1'287387
˖7&/2:63(('%:.
˖7&0,''/(63(('%:.
˖7&3/$,1%:63;
˖7&3/$,1%:'3;
7(67
(;(&87(
.(<
                        & 
0$,1
Item/Display
Content
Adjustment 
range
Default 
value
Actual output 
setting range
Default value 
of actual 
output value
A
TC1 LOW SPEED BW K
Primary transfer bias 
reference value
Low speed mode
51 - 255
95
2 - 30
A
8
A
B
TC1 MIDDLE SPEED BW K
Middle speed mode
51 - 255
131
2 - 30
A
13
A
C
TC2 PLAIN BW SPX
Secondary transfer 
bias reference value
Standard 
paper mode
Front surface mode
51 - 255
111
–2 - –80
A
–25
A
D
TC2 PLAIN BW DPX
Back surface mode
51 - 255
111
–2 - –80
A
–25
A
E
TC2 HEAVY BW SPX
Heavy paper 
mode
Front surface mode
51 - 255
93
–2 - –80
A
–10
A
F
TC2 HEAVY BW DPX
Back surface mode
51 - 255
93
–2 - –80
A
–10
A
G
TC2 OHP BW 
OHP
51 - 255
85
–2 - –80
A
–8
A
H
TC2 ENVELOPE BW
Envelope
51 - 255
124
–2 - –80
A
–30
A
I
TC2 THIN BW
Thin paper
51 - 255
111
–2 - –80
A
–25
A
J
TC2 GLOSSY BW
Gloss paper
51 - 255
72
–2 - –80
A
–10
A
K
TC2 CLEANING
Cleaning mode
51 - 255
67
–2 - -80
A
–8
A
L
TC2 CLEAN LOW SPD
Secondary transfer 
cleaning bias 
reference value
Low speed print mode
0 - 255
16
–100V - 1500V
0V
M
TC2 CLEAN MIDDLE SPD
Middle speed print mode
0 - 255
16
–100V - 1500V
0V
N
TC2 CLEAN CLEANING 
Cleaning mode
0 - 255
143
–100V - 1500V
800V
O
PTC LOW SPEED BW
PTC current output 
reference value
Low speed mode
0 - 255
133
0
A - –700A
–300
A
P
PTC MIDDLE SPEED BW
Middle speed mode
0 - 255
133
0
A - –700A
–300
A
Q
CASE VOLT LOW BW
PTC case voltage 
reference value
Low speed mode
0 - 255
0
0V - –1000V
0V
R
CASE VOLT MID BW
Middle speed mode
0 - 255
0
0V - –1000V
0V
S
PEEL VOLT LOW BW
Separation discharge 
reference value
Low speed mode
51 - 255
200
 –50 - –3000V
–2200V
T
PEEL VOLT MIDDLE BW
Middle speed mode
51 - 255
200
 –50 - –3000V
–2200V
MX-C400P/C380P, MX-B400P/B380P/B382P  ADJUSTMENTS  4 – 7
 
ADJ 2
Image density sensor (image 
registration sensor) adjustment
There are some parts variations in the image density sensor sec-
tion. Therefore, the absolute detection level differs in each
machine. To correct this, calibration is executed.
This adjustment is needed in the following situations:
* When the color image density sensor (image registration sensor
F) is replaced.
* When the image registration sensor unit is replace.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
The targets of the adjustment are the color image density sensor
(image registration sensor F) and the black image density sensor
(image registration sensor R). There are following adjustment
methods.
* Color image density sensor (image registration sensor F) calibra-
tion SIM44-13
* Color image density sensor (Image registration sensor F) calibra-
tion value setting (SIM44-61)
* Black image density sensor (image registration sensor R) cali-
bration SIM44-2
NOTE: The color image density sensor detects color image density
and image registration on front frame side, the black image
density sensor detects black image density and image reg-
istration on rear frame side. That is, two functions is
assigned to each one sensor.
Before executing this adjustment, check to confirm the fol-
lowing items.
* Check to confirm that the color image density sensor (image reg-
istration sensor F) and the black image density sensor (image
registration sensor R) are clean.
* Check to confirm that the image density sensor calibration plate
is clean.
* Check to confirm that the transfer belt is clean and free from
scratches.
 
2-A
Color image density sensor (image 
registration sensor F) calibration 
(MX-C400P/C380P)
Perform the color image density sensor (image registration sensor
F) calibration in one of the following methods.
* Color image density sensor (Image registration sensor F) calibra-
tion value setting (Method by SIM44-61)
When the registration sensor unit is replaced, the calibration
value is set manually with this method. The calibration jig is not
required.
When, however, the color image density senor itself is replaced,
use the calibration jig and execute SIM44-13 to perform calibra-
tion.
* Color image density sensor (Image registration sensor F) calibra-
tion value setting (Method by SIM44-13)
When the color image density sensor itself is replaced, use the
calibration jig and perform calibration with this method.
(Color image density sensor (Image registration sensor F) cal-
ibration value setting (Method by SIM44-61))
1)
Enter the SIM44-61 mode.
2)
Select an item to be set.
3)
Set the set value. (Enter the set value, and press [OK] key and
OSA shortcut key.)
The set value is the specified on the label attached to the reg-
istration sensor unit.
(Color image density sensor (Image registration sensor F) cal-
ibration (Method by SIM44-13))
1)
Enter the SIM44-13 mode.
2)
With [EXECUTE] button selected, press [OK] key.
The shutter plate of the color image density sensor (Image
registration sensor F) is opened, and the message that the pri-
mary transfer unit is removed is displayed.
Item/Display
Content
Setting 
range
Default 
value
A
PCS_CL CARB OUT
Calibration plate sensor 
value
1 - 255
108
B
PCS_CL LED ADJ
Color sensor light 
emitting quantity 
adjustment value
1 - 255
21
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
˷̚˹
3$7&+6($/$'-8670(17˄,1387
˖3&6B&/&$5%287
˖3&6B&//('$'-
7(67
.(<
                        & 
0$,1
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
3$7&+6($/$'-8670(17
3&6B&/&$5%287
3&6B&//('$'-
7(67
(;(&87(
㩷㪈㪆㩷㪈
.(<
0$,1
Page of 127
Display

Click on the first or last page to see other MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) service manuals if exist.