DOWNLOAD Sharp MX-C300P / MX-C300PE / MX-C300PL Service Manual ↓ Size: 26.91 MB | Pages: 127 in PDF or view online for FREE

Model
MX-C300P MX-C300PE MX-C300PL
Pages
127
Size
26.91 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual (Revised May 2016).
File
mx-c300p-mx-c300pe-mx-c300pl.pdf
Date

Sharp MX-C300P / MX-C300PE / MX-C300PL Service Manual ▷ View online

MX-C300P  SIMULATION  6 – 58
 
67-52
Purpose
Adjustment
Function (Purpose)
Used to reset the printer color balance
adjustment (adjustment for each dither) to
the default value. (The set values of SIM67-
33 are set to the default values.)
Section
Operation/Procedure
This simulation is used to reset the adjustment values of SIM67-54
and SIM67-33 to the default values.
1) Select an item to be reset to the default (for each dither) with 10
keys.
To reset the adjustment values of all the items, select [ALL].
2)
Press [OK] key.
No.
Item/Display
Content
1
ALL
All dither value
2
HEAVY PAPER
Heavy paper dither value
3
1BIT
1 bit dither value
4
2BIT
2 bit dither value
5
B/W
Monochrome dither value
MX-C300P  TROUBLESHOOTING  7 – 1
MX-C300P
6HUYLFH0DQXDO
[7] TROUBLESHOOTING
1.  Error code and troubleshooting
A. General
When a trouble occurs in the machine or when the life of a consum-
able part is nearly expired or when the life is expired, the machine
detects and displays it on the display section. This allows the user and
the serviceman to take the suitable action. In case of a trouble, this
feature notifies the occurrence of a trouble and stops the machine to
minimize the damage.
B. Function and purpose
1)
Securing safety. (The machine is stopped on detection of a trou-
ble.)
2)
The damage to the machine is minimized. (The machine is
stopped on detection of a trouble.)
3)
By displaying the trouble content, the trouble position can be
quickly identified. (This allows to perform an accurate repair,
improving the repair efficiency.)
4)
Preliminary warning of running out of consumable parts allows to
arrange for new parts in advance of running out. (This avoids
stopping of the machine due to running out the a consumable
part.)
C. Self diag message kinds
The self diag messages are classified as shown in the table below.
D. Self diag operation
The machine always monitors its own state.
When the machine recognizes a trouble, it stops the operation and
displays the trouble message.
A warning message is displayed when a consumable part life is nearly
expired or is expired.
When a warning message is displayed, the machine may be or may
not be stopped.
The trouble messages and the warning messages are displayed by
the LCD and lamp.
Some trouble messages are automatically cleared when the trouble is
repaired. Some other troubles must be cleared by a simulation.
Some warning messages of consumable parts are automatically
cleared when the trouble is repaired. Some other warning messages
must be cleared by a simulation.
Class 1
User
Warning of troubles which can be recovered by the 
user. (Paper jam, consumable part life expiration, 
etc.)
Service
Warning of troubles which can be recovered only by 
a serviceman. (Motor trouble, maintenance, etc.)
Others
-
Class 2
Warning
Warning to the user, not a machine trouble 
(Preliminary warning of life expiration of a 
consumable part, etc.)
Trouble
Warning of a machine trouble. The machine is 
stopped.
Others
-
ਘၑ
Πρήσȟ࠙࣬
Πρήσȟ࠙࣬
൲ै೪গ
ະၻࡔ֦ͬ಺औ
ΘͼͺΈȪΞΑΠ΋ζϋΡȫ
൝ͤ͢ͅুࡨ૷౯ιΛΓȜΐ
ٜੰ
ఞܥેఠ
ક࿍ΩȜΜ࢐۟¦༞ݯ
໘ܦ
ඤယͬນা
Πρήσ
Πρήσ
࠙࣬
࠙࣬
ZFT
OP
Monitors the machine
conditions.
Detects/analyzes
the content.
Trouble/Warning
Trouble/Warning
Repair
Troubleshoot the cause.
Standby state
The machine is stopped.
The content is displayed.
Warning
Warning
Trouble
No
YES
Trouble
Reset
Replace or supply
the consumable part.
Cancel the self-diagnostic
message with the 
diagnostic (test commands).
A consumable
part has reached
its lifetime
MX-C300P  TROUBLESHOOTING  7 – 2
E. Breakdown sequence
(1)
Error code and operatable mode
Error where only history data are saved
O: Operation enabled
✕: Operation disabled
(2)
Trouble detection sequence and trouble cancel 
sequence when turning on the power
(3)
How to cancel the error code
Trouble content
Judgment 
block
Trouble code 
Operatable Mode 
Print
List print
OPU communication trouble
OPU communication trouble
MFPC
U9(00,81,82,84,88,99)
Backup battery voltage fall trouble
Backup battery voltage fall 
U1 (01)
X
X
Connection trouble
Operation disable trouble 2
Memory error (included not installed 
the expansion RAM) 
A0(30), 
U2 (00, 05, 06, 11)
X
X
Operation disable trouble 3
Image memory trouble, decode 
error
E7(01)
X
X
Laser trouble
LSU breakdown 
E7 (20, 28, 29)
L6 (10)
X
X
Engine trouble 2
MFPC troubles (motor, fusing, etc.) 
C1 (10)F2 (22, 40, 64, 70, 74)H2 (00, 
02, 03)H3 (00, 02)H4 (00)H5 (01)H7 
(10)L4 (02, 03, 04, 06, 17, 32, 34, 35, 
40)L8 (02)
X
X
Process system trouble
Process system breakdown 
E7 (21, 22, 23)F2 (23,  41, 42, 43, 
65, 66, 67, 71, 72, 73, 75, 76, 77)
X
X
Paper feed tray 2 trouble
Paper feed tray 2 breakdown 
F3 (22)
X
X
Other troubles
Other troubles 
EE (EC, EL, EU)
X
X
Process control trouble
Process control breakdown (MFPC 
detection) 
F2 (39, 47, 49, 50, 51, 58, 78)
X
X
Trouble content
Judgment 
block
Trouble code
Operatable mode
Print
List print
FAST Notific-
aion to host
Error history
MFPC
F2 (45), E7(38)
O
O
O
0OWER
(
3AVED
5
3AVED
5
3AVED
5
3AVED
&
3AVED
4ROUBLE
7HEN
(
3)-
#OLOR
3)-
&
3)-
%ACH
-&0
#OMMUNICATION
4ROUBLE
7HEN
4ROUBLE
4ROUBLE
SIM
4ROUBLE
Simulation
Error Code
SIM14
U1, H3, H4, H5
SIM16
U2
Power OFF - ON
Other errors
MX-C300P  TROUBLESHOOTING  7 – 3
F. Error code list
(1)Error code 
Trouble code
Trouble code content
Trouble 
detection
Mechanism
Option
Electricity
Supply
Main 
code
Sub 
code
A0
30
Machine configuration error
MFPC
O
C1
10
Main charger trouble (K)
MFPC
O
E7
20
LSU BD(KC) detection error / LSU LD deform error (K)
MFPC
O
21
LSU LD deform error (C)
MFPC
O
22
LSU LD deform error (M)
MFPC
O
23
LSU BD(MY) detection error / LSU LD deform error (Y)
MFPC
O
28
LSU-MFPC connection error
MFPC
O
29
LSU ASIC frequency error
MFPC
O
38
Zoran chip AD adjustment error
MFPC
O
EE
EC
Automatic toner density adjustment error (Sampling level 76 - 117/139 - 178)
MFPC
O
EL
Automatic toner density adjustment error (Overtoner)
MFPC
O
EU
Automatic toner density adjustment error (Undertoner)
MFPC
O
F2
22
Discharge lamp trouble (K)
MFPC
O
23
Discharge lamp trouble (CMY)
MFPC
O
39
Main unit thermister trouble
MFPC
O
40
Toner density sensor trouble (K)
MFPC
O
41
Toner density sensor trouble (C)
MFPC
O
42
Toner density sensor trouble (M)
MFPC
O
43
Toner density sensor trouble (Y)
MFPC
O
45
K image density sensor trouble
MFPC
O
47
Ozone duct thermister trouble
MFPC
O
49
LSU thermister trouble
MFPC
O
50
K drum phase sensor trouble
MFPC
O
51
CL drum phase sensor trouble
MFPC
O
58
Main unit humidity sensor trouble
MFPC
O
64
Toner supply operation trouble (K)
MFPC
O
65
Toner supply operation trouble (C)
MFPC
O
66
Toner supply operation trouble (M)
MFPC
O
67
Toner supply operation trouble (Y)
MFPC
O
70
Improper toner cartridge detection (K)
MFPC
O
71
Improper toner cartridge detection (C)
MFPC
O
72
Improper toner cartridge detection (M)
MFPC
O
73
Improper toner cartridge detection (Y)
MFPC
O
74
Toner cartridge CRUM error (K)
MFPC
O
75
Toner cartridge CRUM error (C)
MFPC
O
76
Toner cartridge CRUM error (M)
MFPC
O
77
Toner cartridge CRUM error (Y)
MFPC
O
78
Image density sensor for the registration trouble (transfer belt reflection rate trou-
ble)
MFPC
O
F3
22
Paper feed tray 2 lift operation trouble
MFPC
O
H2
00
Thermister open trouble (TH_UM_AD2)
MFPC
O
02
Sub thermister open trouble (TH_US)
MFPC
O
03
Compensation thermister open trouble
MFPC
O
H3
00
Compensation thermister open trouble (TH_UM)
MFPC
O
02
Fusing section high temperature trouble (TH_US)
MFPC
O
H4
00
Fusing section low temperature trouble (TH_UM_AD2)
MFPC
O
H5
01
5 times continuous POD1 not-reach jam
MFPC
O
H7
10
Fusing low temperature recovery trouble (TH_UM_AD2).
MFPC
O
L4
02
Paper feed motor trouble
MFPC
03
Fusing motor lock trouble
MFPC
O
04
Developing motor trouble
MFPC
O
06
Transfer unit lift trouble
MFPC
O
17
Drum motor lock trouble
MFPC
32
Power source cooling fan trouble
MFPC
O
34
LSU fan trouble
MFPC
O
35
Fusing cooling fan trouble
MFPC
O
40
Ozone fan motor 1 trouble
MFPC
L6
10
Polygon motor trouble
MFPC
O
L8
02
Full wave signal error
MFPC
O
PC
-
Personal counter not detected
MFPC
O
U1
01
Battery trouble
MFPC
O
Page of 127
Display