Sharp MX-B382 (serv.man6) Service Manual ▷ View online

MX-B382/B402  ADJUSTMENTS  4 – 2
3. Details of adjustment
 
ADJ 1
Adjusting high voltage values
 
1-A
Adjust the main charger grid voltage
This adjustment is needed in the following situations:
* When the MC high voltage power PWB is replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
1)
Enter the SIM 8-2 mode.
2)
Select an output mode and an item to be adjusted.
3)
Enter the adjustment value (specified value) in the middle
speed mode, and press [OK] key.
When [EXECUTE] key is pressed, the voltage entered in the
procedure 3 is outputted for 30sec and the set value is saved.
When [EXECUTE] key is pressed, the output is stopped.
Enter the adjustment value of each mode which is speci-
fied on the label attached on the MC high voltage power
PWB.
NOTE: Note that the adjustment value may differ depending on the
MC high voltage power PWB.
Since the adjustment value label is attached on the MC
high voltage PWB, the PWB must be removed in order to
check the adjustment value.
This is a troublesome procedure. Therefore, it is advisable
to put down the adjustment value in advance.
GBK:XXX
When the adjustment value (specified value) of the middle speed
mode is set, the adjustment values of the other modes are auto-
matically set according to the middle speed mode setting in a cer-
tain relationship.
NOTE: Since the high voltage output cannot be checked with a
digital multi meter in this model, a judgment of the output
must be made by checking the print image quality.
 
1-B
Adjust the developing bias voltage
This adjustment is needed in the following situations:
* When the MC high voltage power PWB is replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
1)
Go through the modes specified in Simulation 8-1.
2)
Select an output mode and an item to be adjusted.
3)
Enter the adjustment value (specified value) in the middle
speed mode, and press [OK] key.
When [EXECUTE] key is pressed, the voltage entered in the
procedure 3 is outputted for 30sec and the set value is saved.
When [EXECUTE] key is pressed, the output is stopped.
Enter the adjustment value of each mode which is specified on
the label attached on the MC high voltage power PWB.
NOTE: Note that the adjustment value may differ depending on the
MC high voltage power PWB.
Since the adjustment value label is attached on the MC
high voltage PWB, the PWB must be removed in order to
check the adjustment value.
This is a troublesome procedure. Therefore, it is advisable
to put down the adjustment value in advance.
DVK:XXX
ADJ 18
Adjust the developing unit
18A
Adjust the developing doctor gap
18B
Adjust the developing roller main pole position
18C
Toner density control reference value setting
25-2
Job No
Adjustment item list
Simulation
Mode
Item/Display
Content
Setting range
MIDDLE
A
MIDDLE 
SPEED GB_K
K charging/grid bias set 
value at middle speed
150 - 850
LOW
A
LOW SPEED 
GB_K
K charging/grid bias set 
value at low speed
150 - 850
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
0+9*5,'6(77,1*$1'287387
˷̚˹
˖0,''/(63(('*%B.
2.
(;(&87(
/2:
0,''/(
Mode
Item/Display
Content
Setting 
range
MIDDLE
A
MIDDLE SPEED 
DVB_K
K developing bias set 
value at middle speed
0-600
LOW
A
LOW SPEED 
DVB_K
K developing bias set 
value at low speed
0-600
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
'96(77,1*$1'287387
˷̚˹
˖0,''/(ǂ63(('ǂ'9%B.
2.
(;(&87(
/2:
0,''/(
MX-B382/B402  ADJUSTMENTS  4 – 3
When the adjustment value (specified value) of the middle speed
mode is set, the adjustment values of the other modes are auto-
matically set according to the middle speed mode setting in a cer-
tain relationship.
NOTE: Since the high voltage output cannot be checked with a
digital multi meter in this model, a judgment of the output
must be made by checking the print image quality.
 
1-C
Transfer voltage adjustment
This adjustment is needed in the following situations:
* When the TC high voltage PWB is replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
1)
Go through the modes specified in Simulation 8-6.
2)
Select an item to be adjusted.
Enter the adjustment value (specified value), and press [OK]
key.
When [EXECUTE] key is pressed, the voltage entered in the
procedure 3 is outputted for 30sec and the set value is saved.
When [EXECUTE] key is pressed, the output is stopped.
By setting the default value (specified value), the specified out-
put is provided.
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
7+96(77,1*$1'287387
˷̚˹
˖7&/2:63(('%:.
˖7&0,''/(63(('%:.
˖7&3/$,1%:63;
˖7&3/$,1%:'3;
˖7&+($9<%:'3;
˖7&+($9<%:63;
˖7&2+3%:
˖7&(19(/23(%:
˖7&7+,1%:
˖7&*/266<%:
˖7&&/($1,1*
˖7&&/($1/2:63'
2.
(;(&87(
Item/Display
Content
Adjustment 
range
Default 
value
Actual output 
setting range
Default value 
of actual 
output value
A
TC1 LOW SPEED BW K
Primary transfer bias 
reference value
Low speed mode
51 - 255
95
2 - 30
A
8
A
B
TC1 MIDDLE SPEED BW K
Middle speed mode
51 - 255
131
2 - 30
A
13
A
C
TC2 PLAIN BW SPX
Secondary transfer 
bias reference value
Standard 
paper mode
Front surface mode
51 - 255
111
–2 - –80
A
–25
A
D
TC2 PLAIN BW DPX
Back surface mode
51 - 255
111
–2 - –80
A
–25
A
E
TC2 HEAVY BW SPX
Heavy paper 
mode
Front surface mode
51 - 255
93
–2 - –80
A
–10
A
F
TC2 HEAVY BW DPX
Back surface mode
51 - 255
93
–2 - –80
A
–10
A
G
TC2 OHP BW 
OHP
51 - 255
85
–2 - –80
A
–8
A
H
TC2 ENVELOPE BW
Envelope
51 - 255
124
–2 - –80
A
–30
A
I
TC2 THIN BW
Thin paper
51 - 255
111
–2 - –80
A
–25
A
J
TC2 GLOSSY BW
Gloss paper
51 - 255
72
–2 - –80
A
–10
A
K
TC2 CLEANING
Cleaning mode
51 - 255
67
–2 - -80
A
–8
A
L
TC2 CLEAN LOW SPD
Secondary transfer 
cleaning bias 
reference value
Low speed print mode
0 - 255
16
–100V - 1500V
0V
M
TC2 CLEAN MIDDLE SPD
Middle speed print mode
0 - 255
16
–100V - 1500V
0V
N
TC2 CLEAN CLEANING 
Cleaning mode
0 - 255
143
–100V - 1500V
800V
O
PTC LOW SPEED BW
PTC current output 
reference value
Low speed mode
0 - 255
133
0
A - –700A
–300
A
P
PTC MIDDLE SPEED BW
Middle speed mode
0 - 255
133
0
A - –700A
–300
A
Q
CASE VOLT LOW BW
PTC case voltage 
reference value
Low speed mode
0 - 255
0
0V - –1000V
0V
R
CASE VOLT MID BW
Middle speed mode
0 - 255
0
0V - –1000V
0V
S
PEEL VOLT LOW BW
Separation discharge 
reference value
Low speed mode
51 - 255
200
 –50 - –3000V
–2200V
T
PEEL VOLT MIDDLE BW
Middle speed mode
51 - 255
200
 –50 - –3000V
–2200V
MX-B382/B402  ADJUSTMENTS  4 – 4
 
ADJ 2
Image density sensor 
adjustment
NOTE: Before executing this adjustment, check to confirm the fol-
lowing items.
* Check to confirm that the image density sensor is clean.
* Check to confirm that the transfer belt is clean and free from
scratches.
NOTE: This adjustment executes automatically at the outset of
registration adjustment operation and process control oper-
ation as well as SIM44-2.
Normally, therefore, it is not required to perform this adjust-
ment. It is performed only when the sensor is replaced or
when the adjustment result is checked.
1)
Enter SIM44-2 mode.
2)
Press [EXECUTE] key.
The image density sensor is automatically adjusted.
After completion of the adjustment, the adjustment result is
displayed and [EXECUTE] key returns to the normal display.
If the adjustment is not completed normally, "ERROR" is dis-
played.
When an error occurs, check the following sections for any
abnormality.
• Image density sensor
• PCU PWB
• Transfer belt (dirt, scratch)
• Transfer belt cleaner
If any abnormality is found, repair and adjust again.
If an error occurs, the adjustment result is not revised.
 
ADJ 3
Image skew adjustment 
(LSU unit)
This adjustment is needed in the following situations:
* When the LSU unit is replaced.
* When the LSU unit is removed from the main unit.
The image skew adjustment (LSU unit) is performed by changing
the parallelism of the LSU unit scan laser beams for the OPC drum.
1)
Enter SIM64-2 mode.
Set the set items to the values shown below.
A: 1 B: 1 C: 254 D: 255
Display/Item
Content
Range
Default
A
PCS_K LED ADJ
Image density sensor light 
emitting quantity 
adjustment value
1 - 255
32
B
PCS_K DARK
Dark voltage
0 - 255
0
C
PCS_K GRND
Belt base detection level 
when completion of Item A 
adjustment
0 - 255
0
D
PCS_K BELT MAX
Maximum value of belt 
base detection level
0 - 255
0
E
PCS_K BELT MIN
Minimum value of belt 
base detection level
0 - 255
0
F
PCS_K BELT DIF
Belt base detection level 
difference 
(Item D - Item E)
0 - 255
0
G
REG_R LED ADJ
Image density sensor light 
emitting quantity 
adjustment value
1 - 255
32
H
REG_R DARK
Image density sensor dark 
voltage
0 - 255
0
I
REG_R GRND
Belt base detection level 
when completion of Item 
G adjustment
0 - 256
0
J
REG_R BELT MAX
Maximum value of belt 
base detection level
0 - 255
0
K
REG_R BELT MIN
Minimum value of belt 
base detection level
0 - 255
0
L
REG_R BELT DIF
Belt base detection level 
difference (Item J - Item K)
0 - 255
0
M
REG_R PATCH (K)
Patch detection level for 
check
0 - 255
0
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
352&21*$,1$'-8670(17
(;(&87(
3&6B./('$'-
5(*B5%(/70$;
3&6B.'$5.ǂ
5(*B5%(/70,1
3&6B.*51'
5(*B5%(/7',)
3&6B.%(/70$;
3&6B.%(/70,1
5(*B53$7&+.
3&6B.%(/7',)
5(*B5/('$'-
5(*B5'$5.
5(*B5*51'
Error name
Error content
Image density sensor 
adjustment abnormality
PCS_K LED ADJ error 
The target is not reached by 3 times of 
retry.
Substrate scan abnormality
PCS_K GRND error 
Effective difference between the upper 
and lower values of the belt substrate 
circuit, outside the range
Registration sensor R 
adjustment abnormality
REG_R LED ADJ error 
The target is not reached by 3 times of 
retry.
Registration substrate R 
scan abnormality
REG_R GRND error 
Effective difference between the upper 
and lower values of the belt substrate 
circuit, outside the range
Error display
Error content
BK_SEN_ADJ
_ERR
Image density 
sensor adjustment 
abnormality
PCS_K LED ADJ error (The 
target value is not obtained after 
retried three times.)
BELT_READ
_ERR
Transfer belt 
surface reading 
abnormality
PCS_K GRND error (The surface 
detection level is maximum or the 
minimum value difference is 
outside a reference range.)
REG_SEN_R
_ADJ_ERR
Sensor adjustment 
abnormality
REG_R LED ADJ error (The 
target value is not obtained after 
retried three times.)
REG_BELT_R
_READ_ERR
Transfer belt 
surface reading 
abnormality
REG_R GRND error (The 
surface detection level is 
maximum or the minimum value 
difference is outside a reference 
range.)
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
6(/)35,17%:6(59,&(
˷̚˹
˖35,173$77(51̚̚
˖'27'27˚˙,)$
˖'27'27˚˙,)$
˖'(16,7<),;(',)$
˖(;32685(̚,)$̚67$1'$5'',7+(5
˖08/7,&2817
˖3$3(5&6
˖'83/(;12
˖3$3(5ǂ7<3(3/$,1
2.
(;(&87(
MX-B382/B402  ADJUSTMENTS  4 – 5
2)
Select the tray with A4 (11" x 8.5") paper in it.
3)
Press [EXECUTE] key.
The check pattern is printed out.
4)
Check the printed image for any skew.
There are following two methods of checking the image for any
skew (right angle).
Method 1: 
Measure the length of the diagonal lines of the rectangle print
pattern. Check the difference in the length of the diagonal lines
for judgment of good or no good
Method 2: 
Compare the right angle of vertical side/horizontal side of the
rectangle print pattern and the right angle sides of A4 (11" x
8.5") paper for judgment of good or no good.
(NOTE)
In the case of Method 2, the right angle of paper to be used
may not be exact. Be sure to check the right angle of paper to
be used in advance.
(Method 1)
a) Measure the length of the diagonal lines of the rectangle 
print pattern.
b) Calculate the difference between the measured lengths C 
and D of the diagonal lines.
c) Check to insure that the difference between C and D is in 
the following range.
C – D = 
0.8mm
If the difference between C and D is in the above range, there
is no need to adjust.
(Method 2)
a) Fit the side of A4 or 11" x 8.5" paper to the long side of the 
rectangle print pattern.
b) Measure the shift distance between vertical side of paper 
and side of the rectangle print pattern.
If the above distances (left and right) are 0.5mm or less, 
there is no need to adjust.
If not, execute the following procedures.
5)
Open the front cabinet, and remove the waste toner box.
6)
Turn the LSU unit image skew adjustment screw to adjust.
(When Method 1 is used to check the image for any skew
(right angle) in procedure 4 in advance)
Diagonal line C is longer than diagonal line D: Turn the adjust-
ment screw clockwise.
Diagonal line C is shorter than diagonal line D: Turn the adjust-
ment screw counterclockwise.
(When Method 2 is used to check the image for any skew
(right angle) in procedure 4 in advance)
When the image is skewed in the arrow direction A, turn the
adjustment screw clockwise. When the image is skewed in the
arrow direction B, turn the adjustment screw counterclockwise.
7)
Install the waste toner box, and close the front cabinet.
8)
Perform the procedures 3) - 4).
(Perform the procedures 3) - 8) until a satisfactory result is
obtained.)
 
ADJ 4
Print engine image 
magnification ratio adjustment 
(Main scanning direction) 
(Print engine section) 
(Manual adjustment)
This adjustment is needed in the following situations:
* When the LSU (writing) unit is replaced.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
1)
Go through the modes specified in Simulation 50-10.
2)
Select A4 (11" x 8.5") paper.
Diagonal line D
Diagonal line C
Direction B
Direction A
Comparison line
0.5mm or ress
K
A
B
ǂǂǂ6,08/$7,21ǂǂ12
7(67
3$3(5&(17(52))6(76(783
˷̚@
˖%.0$*
˖0$,10)7
˖0$,1&6
˖0$,1&6
˖0$,1&6
˖0$,1&6
˖0$,1$'8
˖68%0)7
˖68%&6
˖68%'6.
˖68%$'8
˖08/7,&2817
2.
&/26(
(;(&87(
Page of 127
Display

Click on the first or last page to see other MX-B382 (serv.man6) service manuals if exist.