DOWNLOAD Sharp MX-6240N / MX-7040N (serv.man32) Service Manual ↓ Size: 6.45 MB | Pages: 49 in PDF or view online for FREE

Model
MX-6240N MX-7040N (serv.man32)
Pages
49
Size
6.45 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Section 13 Operational Descriptions - Updated November 2012
File
mx-6240n-mx-7040n-sm32.pdf
Date

Sharp MX-6240N / MX-7040N (serv.man32) Service Manual ▷ View online

MX-7040N  OPERATIONAL DESCRIPTIONS  13 – 37
Sensitivity adjustment of the color sensor light receiving ele-
ments (Photo transistors)
Purpose: To maintain the sensitivity of the light receiving elements
even if the environmental conditions (temperature and humidity)
vary.
Execution timing: This adjustment is executed in the process con-
trol when the temperature or the humidity varies.
Method: Use the patch written on the primary transfer to adjust the
sensor sensitivity.
Light emitting current of the sensor LED (Light emitting diode)
Purpose: To maintain the light emitting quantity of the sensor even
if the sensor LED is aged or the environmental conditions vary.
Execution timing: Every time when the process control is made.
Method: Reflection on the surface of the primary transfer belt is
used to adjust the sensor sensitivity.
b. High density process control operation (Toner patch generation and density correction operations)
1)
When the machine enters the high density process control mode, the secondary transfer unit remains in the printing position.
2)
While changing the DV bias voltage step by step, a number of toner patches in different densities are generated on the primary transfer
belt.
Front: The C toner patch is generated.
Center: The Bk, M toner patch is generated.
Rear: The Y toner patch is generated.
3)
Each toner patch density is detected by the image density sensor, and the DV bias correction voltage is calculated in the PCU PWB so that
the proper density is obtained from the relation between the DV bias voltage at the time when each toner patch is made and the toner
patch density.
MX-7040N  OPERATIONAL DESCRIPTIONS  13 – 38
(3)
Setting of process control execution conditions
a. General
The SIM44-62 function facilitates changing the process control execution conditions.
The SIM44-62 function also allows collective change of the set contents of SIM44-4 and SIM44-28 easily.
This is used to assure stable image qualities by executing proper operations of the process control according to the machine use status.
b. SIM44-62 function and use
• Changes the image density in the high density area.
• Changes the execution frequency of the process control.
c. Setting method
Enter the SIM44-62 mode, and select the set item.
• To change the image density in the high density area, select PROCON TARGET.
• To change the frequency of the process control operations, select PROCON MODE.
When PROCON TARGET is selected.
1)
Select the density level.
Relation between the selected density level and the output image density
CL ID DOWN
The densities of C, M, and Y decrease. (The C/M/Y high density process control target values decrease.)
CL ID UP
The densities of C, M, and Y increase. (The C/M/Y high density process control target values increase.)
BK ID DOWN
The density of K decreases. (The high density process control target value decreases.)
BK ID UP
The density of K increases. (The high density process control target value increases.)
ALL ID DOWN
The densities of C, M, Y and K decrease. (The C/M/Y/K high density process control target values decrease.)
ALL ID UP
The densities of C, M, Y and K increase. (The C/M/Y/K high density process control target values increase.)
NORMAL
The standard density of C, M, Y and K. (The C/M/Y/K high density process control target values are the standard values.)
ǂǂǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
352&216(77,1*&2//(&7,9(,1387
352&217$5*(7
352&2102'(
ǂǂǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
352&217$5*(76,0&2//(&7,9(,1387
&/,''2:1
&/,'83
%.,''2:1
%.,'83
$//,''2:1
$//,'83
1250$/
$5(<28685("
<(6
12
(;(&87(
MX-7040N  OPERATIONAL DESCRIPTIONS  13 – 39
Relation between the selected density level and the SIM44-4 set values
2)
Press [EXECUTE] key.
3)
Press [YES] key.
The SIM44-4 set value varies according to the selected density level.
4)
Execute SIM46-74 to adjust the copy and printer color balance.
When PROCON MODE is selected.
1)
Select the execution frequency level of the process control.
Setting level and application
SIM44-62 PROCON TARGET (Selected density level)
Dark
Normal
Light
Item (SIM44-4)
BK High
CL High
ALL High
Normal
BK Down
CL Down
ALL down
A
PCS_F TARGET
204
204
204
204
204
204
204
B
PCS_C TARGET
204
204
204
204
204
204
204
C
PCS_R TARGET
204
204
204
204
204
204
204
D
LED_K OUTPUT
21
21
21
21
21
21
21
E
PCS  ADJSTMENT  LIMIT
4
4
4
4
4
4
4
F
BELT  GROUND  DIF
1
1
1
1
1
1
1
G
BIAS_CL STANDARD DIF
60
60
60
60
60
60
60
H
BIAS_BK  STANDARD  DIF
0
0
0
0
0
0
0
I
BIAS PATCH INTERVAL
60
60
60
60
60
60
60
J
Y_PAT TARGET ID
50
60
60
50
50
45
45
K
M_PAT TARGET ID
50
60
60
50
50
45
45
L
C_PAT TARGET ID
50
60
60
50
50
45
45
M
K_PAT TARGET ID
55
45
55
45
40
45
40
N
HV BK_GROUND LIMIT
60
60
60
60
60
60
60
HIGH QUALITY2
• The execution frequency of the process control is highest.
• It is set when the color image quality is given priority.
• Every time the power is turned ON, the process control is executed.
• The execution frequency of the process control is about 3 times greater than the normal setting.
• For a user who's main jobs are color jobs of more than 100 sheets/day with priority on the color image quality.
HIGH QUALITY1
• The execution frequency of the process control is high.
• It is set when the color image quality is given priority.
• Every time the power is turned ON, the process control is executed.
• For a user of about 100 sheets/day with priority on the color image quality.
NORMAL (Default)
• The process control is executed in the normal frequency.
BW MODE
• The process control is executed in the normal frequency.
• It is set when there are little color jobs and many monochrome jobs.
• The black process control is executed.
• The color process control is occasionally executed according to the color toner consumption.
• The color toner consumption is suppressed.
PRINT PERFORMANCE
• The execution frequency of the process control is low.
• It is set when the job speed is given priority.
• The process control is executed in about 50% of the normal frequency during jobs.
• For jobs of 100 or less, the process control is executed after completion of the jobs.
ǂǂǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
352&2102'(6,0&2//(&7,9(,1387
+,*+48$/,7<
+,*+48$/,7<
35,173(5)250$1&(
%:02'(
1250$/
$5(<28685("
<(6
12
(;(&87(
MX-7040N  OPERATIONAL DESCRIPTIONS  13 – 40
Relation between the selected mode and the SIM44-28 set values
Items out of application: MC_CLEAN_TIME, PTC_CLEAN_TIME_CL, PTC_CLEAN_TIME_BK, DRUM_REVERSE
2)
Press [EXECUTE] key.
3)
Press [YES] key.
The SIM44-28 set value varies according to the selected execution frequency level of the process control.
SIM44-62 and PROCON MODE (process control execution frequency level)
Item (SIM44-28)
Image quality priority 2
Image quality priority 1
Normal
Monochrome priority
Priority on the job 
efficiency
A
INITIAL
0
0
0
0
0
B
SW  ON
0
0
3
3
3
C
 
TIME
0
0
3
3
3
D
HUM_LIMIT
0
0
0
2
0
E
HUM
0
0
0
2
0
F
REV1
0
0
0
1
1
G
REV2_BK
0
0
0
0
0
H
REV2_CL 0
0
0
0
0
I
REFRESH  MODE
1
1
1
1
1
J
DAY
1
1
1
0
1
K
HI-COV
0
0
0
1
1
L
LO-COV
0
0
0
1
1
M
TonerCA-END
0
0
1
1
1
N
JOB_STOP
1
1
1
1
1
O
AVERAGE-PAGE
3
3
3
3
3
P
LIMIT PAGE
10
10
10
50
50
Q
PIX_RATIO_BK
10
10
10
10
10
R
PIX_RATIO_CL
10
10
10
50
10
S
INTERVAL  TIME
3
3
3
3
3
T
HUM HOUR
2
2
2
2
2
U
HUM_DIF
2
2
2
4
4
V
BK_RATIO
5
15
15
30
30
W
M_RATIO
5
15
15
30
30
X
REV1_RATIO
20
20
20
40
40
Y
LOW_RATIO
5
15
15
30
30
Z
COLOR BORDER
20
20
20
100
20
AA
BK  ONLY
5
5
5
6
5
AB
P2P PV_CL
50
50
50
50
50
AC
P2P PV_Bk
50
50
50
50
50
AD
HT_DIF
1
40
40
40
40
AE
RG_ON_SYNC
0
0
0
0
0
AF
RG_TEMP_TIMER
0
0
0
0
0
AG
RG_PERM_TIMER
0
1
1
1
1
AH
RG_HOUR_TIMER
3
5
5
11
11
AI
RG_BW_SYNC
1
1
1
1
1
AN
PAR_CNT SYNC
50
50
50
50
50
AO
PAR_TIMER SYNC
30
30
30
30
30
AP
PAR_TEMP  SYNC
0
0
0
0
0
Page of 49
Display