Copying Equipment / SELF DIAGNOSIS TROUBLE CODES SECTION
File
mx-6201n-mx-7001n-sm20.pdf
Date

Sharp MX-6201N / MX-7001N (serv.man20) Service Manual ▷ View online

MX-7001N  SELF DIAG AND TROUBLE CODE  8 – 29
 
L4-39
Machine ventilation fan right lock
 
L4-40
Ozone fan 1 lock
 
L4-41
Ozone fan 2 lock
 
L4-42
Ozone fan 3 lock
 
L4-43
Paper exit cooling fan center lock
 
L4-44
Power cooling fan 2 lock
 
L4-50
BK process cooling fan lock error
 
L4-51
Color process cooling fan lock error
 
L6-10
Polygon motor lock detection
 
L8-01
No full wave signal
Trouble content
When the machine ventilation fan right is operated, 
the fan operation signal is not detected within the 
specified time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
When the ozone fan 1 is operated, the fan 
operation signal is not detected within the specified 
time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
When the ozone fan 2 is operated, the fan 
operation signal is not detected within the specified 
time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
When the ozone fan 3 is operated, the fan 
operation signal is not detected within the specified 
time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
When the paper exit cooling fan center is operated, 
the fan operation signal is not detected within the 
specified time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
When the power cooling fan 2 is operated, the fan 
operation signal is not detected within the specified 
time.
Section
PCU
Case 1
Cause
Fan connector disconnection
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Case 2
Cause
Fan does not rotate because of other trouble.
Check and 
remedy
Use SIM6-2 to check that the fan is actually 
rotating.
Trouble content
In the BK process cooling fan operation, the fan 
operation signal is not detected within the specified 
time. 
Section
PCU
Case 1
Cause
Because of disconnection of the fan connector or 
other trouble, the fan does not rotate.
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan.
Trouble content
In the color process cooling fan operation, the fan 
operation signal is not detected within the specified 
time.
Section
PCU
Case 1
Cause
Because of disconnection of the fan connector or 
other trouble, the fan does not rotate.
Check and 
remedy
Check the harness and the connector between the 
PCU PWB and the fan. After turning on the power, 
check to confirm that the fan is rotating.
Trouble content
It is judged that the LSU polygon motor lock signal 
is not outputted, and the lock signal is checked 
after 15 sec from starting rotation of the polygon 
motor and it is judged that the polygon motor does 
not rotate properly.
Section
PCU
Case 1
Cause
Disconnection of the LSU connector or the LSU 
inside harness, or breakage
Check and 
remedy
Check connection of the harness and the 
connector.
Case 2
Cause
Polygon motor trouble, LSU PWB trouble
Check and 
remedy
Use SIM61-1 to check the operation of the polygon 
motor.
Replace the LSUcnt PWB. Replace the LSU.
Trouble content
No full wave signal is detected.
Section
PCU
Case 1
Cause
Harness trouble
Check and 
remedy
Check connection of the harness and the 
connector.
Case 2
Cause
Power unit trouble
Check and 
remedy
Replace the power unit.
Case 3
Cause
PCU PWB trouble
Check and 
remedy
Replace the PCU PWB.
MX-7001N  SELF DIAG AND TROUBLE CODE  8 – 30
 
L8-02
Full wave signal width abnormality
 
L8-20
Power controller communication 
trouble
 
PC---
Personal counter not installed
 
U1-01
Battery trouble
 
U2-00
EEPROM read/write error 
(MFP detection)
 
U2-05
HDD/SRAM/EEPROM data 
discrepancy
 
U2-10
SRAM user authentication index 
check sum error
 
U2-11
EEPROM check sum error 
(MFP detection)
 
U2-22
SRAM memory check sum error
Trouble content
The full wave signal is judged as frequency 
abnormality. (The detection frequency is judged as 
65Hz or above or 45Hz or less.)
Section
PCU
Case 1
Cause
Harness trouble
Check and 
remedy
Check the harness and the connector connection.
Case 2
Cause
Power unit trouble
Check and 
remedy
Replace the power unit.
Case 3
Cause
PCU PWB trouble
Check and 
remedy
Replace the PCU PWB.
Trouble content
Communication establishment error/Framing/
Parity/Protocol error
Section
MFP
Case 1
Cause
Connector connection trouble between the mother 
board PWB and the MFPcnt PWB.
MFPcnt PWB mother board connector pin 
breakage
Check and 
remedy
Check the connector connection between the 
mother board PWB and the MFPcnt PWB. Check 
grounding of the machine.
Case 2
Cause
Mother PWB trouble
Check and 
remedy
Replace the mother PWB.
Case 3
Cause
Mother PWB jumper error
Check and 
remedy
Set the mother PWB jumper to the Default side.
Trouble content
The personal counter is not installed.
Section
MFP
Case 1
Cause
The personal counter is not installed.
Check and 
remedy
Install the personal counter.
Trouble content
Backup SRAM battery voltage fall
Section
MFP
Case 1
Cause
1)
Battery life
2)
Battery circuit abnormality
Check and 
remedy
Check that the battery voltage is about 2.5V or 
above.
Trouble content
EEPROM device read/write error
Section
MFP
Case 1
Cause
EEPROM device trouble
Check and 
remedy
Replace the EEPROM device.
Case 2
Cause
EEPROM device contact failure
Check and 
remedy
Check that EEPROM device is properly inserted.
Case 3
Cause
Device access error due to electrical noises
Check and 
remedy
Replace the MFPcnt PWB.
Trouble content
A HDD or SRAM memory for user authentication 
different from that used before turn off the power is 
installed.
Section
MFP
Case 1
Cause
HDD replacement or SRAM memory replacement
Check and 
remedy
Initialize the authentication information with SIM16, 
and import the backup data (exported data by 
device cloning) if any.
Trouble content
User index information (basic data of user 
authentication) check sum error on the SRAM
Section
MFP
Case 1
Cause
1)
SRAM trouble
2)
Hang-up of the control circuit due to electrical 
noises
3)
MFPcnt PWB SRAM access circuit trouble
Check and 
remedy
Use SIM16 to cancel U2 trouble.
Trouble content
Counter information check sum error on the 
EEPROM
Section
MFP
Case 1
Cause
1)
EEPROM device trouble
2)
EEPROM device contact failure
3)
Device access error due to electrical noises
Check and 
remedy
Use SIM16 to cancel U2 trouble.
Trouble content
MFPcnt PWB SRAM memory check sum error
Section
MFP
Case 1
Cause
SRAM trouble
Check and 
remedy
1)
Initialize the communication management 
table registered in SRAM and the FAX soft 
switch.
2)
Since the registered contents have been 
deleted, register them again.
Case 2
Cause
Control circuit hang-up due to electrical noises
Check and 
remedy
Use SIM16 to cancel U2 trouble.
Case 3
Cause
MFPcnt PWB SRAM access circuit trouble
Check and 
remedy
Replace the MFPcnt PWB.
MX-7001N  SELF DIAG AND TROUBLE CODE  8 – 31
 
U2-23
MFPC section SRAM memory 
individual data check sum error
 
U2-24
SRAM memory user authentication
counter check sum error
 
U2-25
Flash memory user authentication
counter check sum error
 
U2-30
Serial number data discrepancy 
(MFP 
 PCU)
 
U2-50
HDD section individual data check
sum error (MFP)
 
U2-80
EEPROM read/write error 
(SCU detection)
 
U2-81
Adjustment value check sum error 
(SCU detection)
 
U2-90
EEPROM read/write error 
(PCU detection)
Trouble content
MFPcnt PWB SRAM memory individual data 
check sum error (Communication management 
table, sender registration data, etc.)
Section
MFP
Case 1
Cause
SRAM trouble
Check and 
remedy
1)
Turn OFF/ON the power to initialize the data 
related to the check sum error contents 
automatically.
2)
Since the registered contents have been 
deleted, register them again.
Case 2
Cause
Control circuit hang-up due to electrical noises
Check and 
remedy
Use SIM16 to cancel U2 trouble.
Case 3
Cause
MFPcnt PWB SRAM access circuit trouble
Check and 
remedy
Replace the MFPcnt PWB.
Trouble content
Check sum error of the user counter on SRAM
Section
MFP
Case 1
Cause
1)
SRAM trouble
2)
Control circuit hang-up due to electrical 
noises
3)
MFPcnt PWB SRAM access circuit trouble
Check and 
remedy
Use SIM16 to cancel U2 trouble.
Trouble content
Check sum error of the user authentication counter 
on FLASH
Section
MFP
Case 1
Cause
Flash trouble. Control circuit hang-up due to 
electrical noises
MFPcnt PWB FLASH access circuit trouble.
Check and 
remedy
Use SIM16 to recalculate the check sum of the 
user counter and save the normal sum value. 
Trouble content
The serial number stored in the PCU differs from 
that stored in the MFP.
Section
MFP
Case 1
Cause
EEPROM is not changed  when the PCU/MFPcnt 
PWB is replaced.
Check and 
remedy
1)
Check that EEPROM is properly set.
2)
Check that EEPROM on the previous PWB is 
inserted to the newly installed PWB.
Trouble content
MFPcnt HDD individual data check sum error 
(One-touch, group, program, etc.)
Section
MFP
Case 1
Cause
Write/read error to/from HDD
Check and 
remedy
1)
Turn OFF/ON the power to initialize the data 
related to the check sum error contents 
automatically.
2)
Since the registered contents have been 
deleted, register them again.
3)
If the trouble is not canceled, replace the 
HDD.
Case 2
Cause
Control circuit hang-up due to electrical noises
Check and 
remedy
Use SIM16 to cancel U2 trouble.
Case 3
Cause
MFPcnt PWB HDD access circuit trouble
Check and 
remedy
Replace the MFPcnt PWB.
Trouble content
Write error to EEPROM
Section
SCU
Case 1
Cause
EEPROM trouble/Not installed.
Check and 
remedy
Check that EEPROM is properly set.
Case 2
Cause
SCU PWB EEPROM access circuit trouble
Check and 
remedy
Replace the SCU PWB. 
Use SIM16 to cancel the trouble.
Trouble content
EEPROM (SCU) check sum error
Section
SCU
Case 1
Cause
Control circuit hang-up due to electrical noises
Check and 
remedy
Use SIM16 to cancel U2 trouble.
Case 2
Cause
EEPROM trouble, installation of EEPROM which is 
not initialized.
Check and 
remedy
To avoid deletion of the counter data/adjustment 
values, use the simulation to save the counter/
adjustment values. 
Replace the SCU PWB. 
Use SIM16 to cancel the trouble.
Case 3
Cause
SCU PWB EEPROM access circuit trouble
Check and 
remedy
Check that EEPROM is properly set.
Trouble content
EEPROM version error, write error to EEPROM
Section
PCU
Case 1
Cause
EEPROM trouble,  installation of EEPROM which 
is not initialized.
Installation of 64KBit EEPROM
Check and 
remedy
Check that EEPROM is properly set.
Check to insure that 256KBit EEPROM is installed.
Case 2
Cause
PCU PWB EEPROM access circuit trouble
Check and 
remedy
To avoid deletion of the counter data/adjustment 
values, use the simulation to save the counter/
adjustment values. (If there is a printer option, 
execute SIM22-1 to save the counter data and the 
adjustment values.) Replace the PCU PWB. Use 
SIM16 to cancel the trouble.
MX-7001N  SELF DIAG AND TROUBLE CODE  8 – 32
 
U2-91
Adjustment value check sum error 
(PCU detection)
 
U5-00
SPF communication trouble
 
U5-16
SPF fan motor trouble
 
U5-30
SPF tray lift-up trouble
 
U5-31
SPF tray lift-down trouble
 
U6-09
LCC lift motor trouble
 
U6-20
LCC communication trouble
 
U6-21
LCC transport motor trouble
 
U6-22
LCC 24V power abnormality
 
U6-23
LCC tray descending trouble 
(reverse winding detection)
Trouble content
EEPROM (PCU) check sum error
Section
PCU
Case 1
Cause
Control circuit hang-up due to electrical noises
Check and 
remedy
Use SIM16 to cancel the trouble.
Case 2
Cause
EEPROM trouble.
Check and 
remedy
Check that EEPROM is properly set.
Use SIM16 to cancel the trouble.
Case 3
Cause
PCU PWB EEPROM access circuit trouble
Check and 
remedy
To avoid deletion of the counter data/adjustment 
values, use the simulation to save the counter/
adjustment values. (If there is a printer option, 
execute SIM22-1 to save the counter data and the 
adjustment values.) Replace the PCU PWB.
Use SIM16 to cancel the trouble.
Trouble content
Communication error between the SCU and the 
DSPF, communication line test error after turning 
on the power or canceling the exclusive simulation
Section
SCU
Case 1
Cause
Malfunction due to electrical noises
Check and 
remedy
Cancel the trouble by turning OFF/ON.
Case 2
Cause
Connector and harness connection trouble or 
disconnection
Check and 
remedy
Check the connector and the harness of the 
communication line.
Case 3
Cause
Control (SCU) PWB trouble. DSPF PWB trouble
Check and 
remedy
Replace the control (SCU) PWB. Replace the 
DSPF PWB.
Trouble content
The motor lock signal is detected during rotation of 
the fan.
Section
SCU
Case 1
Cause
Fan motor trouble, harness of the fan motor 
related, circuit trouble
Check and 
remedy
Use SIM2-3 to check the operation.
Check harness, connector and fan motor related 
circuit.
Trouble content
Lift-up trouble is detected 5 times continuously. 
(STUD does not turn ON within the specified time.)
When re-lifting, a trouble from the first time.
Section
SCU
Case 1
Cause
STUD/STLD trouble
Check and 
remedy
Check STUD/STLD and its harness and connector. 
Check the lift-up unit.
Trouble content
Lift-down trouble (STLD does not turn ON within 
the specified time.)
Section
SCU
Case 1
Cause
STUD/STLD trouble
Check and 
remedy
Check STUD/STLD and its harness and connector. 
Check the lift-up unit.
Trouble content
• The encoder input value is not changed in 
0.2sec (1st time)/0.5sec (2nd time and later) 
after rotation of the motor.
• The motor is rotated for 24sec (LCX2)/48sec 
(LCX3) or more.
Section
PCU
Case 1
Cause
Sensor trouble, LCC control PWB trouble, gear 
breakage, lift motor trouble
Check and 
remedy
Use SIM4-2 and 4-3 to check the operation of the 
sensor and the lift motor. Use SIM15 to cancel the 
trouble.
Trouble content
LCC communication error. Communication line test 
error after turning ON the power or canceling the 
exclusive simulation. LCC and machine model 
codes discrepancy error
Section
PCU
Case 1
Cause
Connector and harness connection trouble or 
disconnection, LCC control PWB trouble, control 
(PCU) PWB trouble, malfunction due to electrical 
noises
Check and 
remedy
Turn OFF/ON the power to cancel the trouble. 
Check the connector and the harness of the 
communication line.
Trouble content
After passing 1 sec from turning ON the motor, the 
lock state of the motor lock signal is detected 
continuously for 1 sec.
Section
PCU
Case 1
Cause
Motor lock, motor RPM abnormality, an 
overcurrent to the motor, LCC control PWB trouble
Check and 
remedy
Use SIM4-3 to check the operation of the transport 
motor.
Trouble content
DC24V power is not supplied to LCC.
Section
PCU
Case 1
Cause
Connector and harness connection trouble or 
disconnection, LCC control PWB trouble, power 
unit trouble
Check and 
remedy
Check the connector and the harness of the power 
line. Check that the power unit and the LCC control 
PWB is of 24V.
Trouble content
Reverse winding of the LCC tray wire is detected.
Section
PCU
Case 1
Cause
Reverse winding of the wire
Check and 
remedy
Check the wire.
Case 2
Cause
Connector and harness connection trouble
Check and 
remedy
Check connection of the connector and the 
harness.
Case 3
Cause
Reverse winding detection SW-ON, reverse 
winding detection SW trouble, LCC control PWB 
trouble
Check and 
remedy
Replace the reverse winding SW and the LCC 
control PWB.
Page of 33